Eaton ZE Overload Relay 1NO + 1NC, 6 → 9 A F.L.C, 9 A Contact Rating, 6 W, 600 V ac, SP
- RS庫存編號:
- 326-829
- 製造零件編號:
- 014708 ZE-9
- 製造商:
- Eaton
Price 个**
HK$598.40
12 現貨庫存,可於4工作日發貨。*
* 交貨日期可能會根據您選擇的數量和交貨地址而變更。
訂單金額滿 HK$850.00 即可享受 免費 送貨服務
單位 | 每單位 |
---|---|
1 + | HK$598.40 |
** 參考價格
- RS庫存編號:
- 326-829
- 製造零件編號:
- 014708 ZE-9
- 製造商:
- Eaton
- COO (Country of Origin):
- DE
Overload Relays
This Eaton Contactor Overload Relay is designed to help your motor continue working in a safe environment by monitoring the current in the motor circuit and breaking the circuit when an electrical overload or phase failure is found. It works by cutting off the current to the motor when a high current situation occurs. As the relay receives the corresponding signal, it trips.
This Eaton product is predominantly designed for imitating the heating prototypes that are a staple for keeping your motors healthy, which increases the motor lifetime. It provides an affordable and efficient way for you to protect your motors, whilst giving you peace of mind that you have sufficient motor protection and control.
Eatons reliable and high-quality Overload Relay offers motor control within a multitude of environments, coming with a 600 V ac control voltage, 6W power rating and a temperature range of -5 to +55 °C. Eaton offer a wide range of reliable contactor overload relays to protect machinery from overheating, keeping your business and its operations accessible.
This Eaton product is predominantly designed for imitating the heating prototypes that are a staple for keeping your motors healthy, which increases the motor lifetime. It provides an affordable and efficient way for you to protect your motors, whilst giving you peace of mind that you have sufficient motor protection and control.
Eatons reliable and high-quality Overload Relay offers motor control within a multitude of environments, coming with a 600 V ac control voltage, 6W power rating and a temperature range of -5 to +55 °C. Eaton offer a wide range of reliable contactor overload relays to protect machinery from overheating, keeping your business and its operations accessible.
Features and Benefits
An affordable way of preventing damage to the motor
Compact in size with a 58mm x 106mm x 45mm (DxLxW)
Wide operating temperature range of -5 to +55 °C
Bimetallic tripping mechanism with trip response from 2 to 10 seconds
Easy to install and reset once they have tripped
Has test and stop functions, assessing quality of the overload relay
Automatic and Manual reset methods
Class 10 A overload
Compact in size with a 58mm x 106mm x 45mm (DxLxW)
Wide operating temperature range of -5 to +55 °C
Bimetallic tripping mechanism with trip response from 2 to 10 seconds
Easy to install and reset once they have tripped
Has test and stop functions, assessing quality of the overload relay
Automatic and Manual reset methods
Class 10 A overload
Eaton Overload Relay, Screw Terminals, Trip-Free Release - ZE Series - 014708 ZE-9
Safeguard your electric motor from excess heat using this overload relay from Eaton. In the event of surplus current or a phase failure, it breaks the circuit to protect motor windings and coils from damage. An FLC motor rating of 6 to 9A means you have free rein to adjust the operating parameters to suit your preferred setting. You can reset the unit manually or automatically for flexibility in its configuration. As it's touch-proof against fingers and the back of your hand, you have peace of mind when handling it. You'll find overload relays like this one used in HVAC systems or manufacturing equipment.
Features & Benefits
• Test button for convenient troubleshooting
• Screw terminals ensure a secure hold on wiring
• ATEX certification indicates it's suitable for the protection of Ex e motors installed in hazardous areas
• Durable performance, thanks to a broad operating temperature range of -5°C to +55°C
• Screw terminals ensure a secure hold on wiring
• ATEX certification indicates it's suitable for the protection of Ex e motors installed in hazardous areas
• Durable performance, thanks to a broad operating temperature range of -5°C to +55°C
How do I mount this relay?
You can fit this device by directly attaching it to the main circuit of your machinery.
Is this relay shock-resistant?
Yes, you can depend on its durability as it's been tested to withstand mechanical shocks of 10g for up to 10ms.
Note
Eaton formerly known as Moeller
Attribute | Value |
---|---|
FLC Motor Rating | 6 → 9 A |
Contact Current Rating | 9 A |
Pole Configuration | SP |
Series | ZE |
Mounting Style | Direct Contactor |
Power Rating | 6 W |
Normal State Configuration | NO/NC |
Reset Method | Automatic, Manual |
Terminal Type | Screw |
Width | 45mm |
Number Of Auxiliary Contacts | 2 |
Length | 106mm |
Depth | 58mm |
Maximum Operating Temperature | +55°C |
Minimum Operating Temperature | -5°C |
Operating Temperature Range | -5 → +55 °C |
Supply Voltage | 690 V |
Contact Voltage Rating | 690 V ac |
Control Voltage | 600 V ac |