Fluke 561 Infrared Thermometer

  • RS庫存編號 613-4193
  • 製造零件編號 2558118
  • 製造商 Fluke
產品概覽和技術數據資料表
法例與合規
不適用
COO (Country of Origin): CN
產品詳細資訊

Fluke 561 IR and Contact Thermometer

Designed for the HVAC/R Engineer or Technician he Fluke 561 IR and contact thermometer, combines the temperature measurement functions that industrial, electrical, and HVAC/R professionals need, all in one tool. It measures both infrared and contact temperature, replacing several other test tools. It’s fast, efficient, and easy to use, saving you valuable time and effort. With the Fluke 561 infrared thermometer, you can also take contact and ambient temperatures in the way that’s best for you. Use the IR thermometer to measure hot, moving, electrically energized, and hard-to-reach objects instantly. Check motors, insulation, breakers, radiant heating, pipes, corroded connections, and wires. Plus, scan ducts, and other hard-to-reach objects from the floor-leave your ladder in the truck. You can use the Fluke 561’s handy flexible pipe probe, or plug in any industry standard type K mini connector thermocouple probe you already own to take super-heat or internal temperatures.

Features and Benefits:

• Two in one thermometer IR and K Type thermocouple
• Velcro pipe probe included
• Laser sighting
• LCD backlit display
• 3 Step emissivity adjustment (Low Medium & High)
• Lightweight and Robust
• Min, Max and Diff measurement function
• Temperature Range -40 to 550C
• Distance to spot size 12:1
• Accuracy +/- 1% of reading or +/-1Deg C. Below 0 +/- 1 Deg C +/- 0.1Deg/1Deg C
• Compatible with standard K type probes
• Includes applications guide and carry case

FEATURES and BENEFITS:

The majority of IR thermometers have a measurement error specification, which shows their best accuracy. The surface being measured can also affect accuracy. Reflective objects result in lower measurements than the actual temperature, whilst non-reflective surfaces give higher measurement. The emissivity of a surface is how effective it is at emitting energy as thermal radiation, as such some IR thermometers have adjustable emissivity settings.
Distance to spot ratio is also essential in providing accurate temperature measurements, if an infrared thermometer is too close to its target area, heat can build up in the device. This can give false readings or damage the temperature sensors, therefore it is essential to always follow a manufacturers guidelines.

. Two in one thermometer IR and K Type thermocouple
. Velcro pipe probe included
. Laser sighting
. 3 Step emissivity adjustment (Low Medium & High)
. Lightweight and Robust
. Min, Max and Diff measurement function
.Measurement Range -40 to 550C
. Distance to spot size 12:1
. Accuracy +/- 1% of reading or +/-1Deg C. Below 0 +/- 1 Deg C +/- 0.1Deg/1Deg C
. Compatible with standard K type probes
. Includes applications guide and carry case

規格
Attribute Value
Absolute Maximum Temperature Measurement +550°C
Temperature Scale Centigrade, Fahrenheit
Absolute Minimum Temperature Measurement -40°C
Distance to Spot Ratio 12:1
Best Accuracy ±1 %
Emissivity 0.7
Model Number p 561
Resolution 0.1 °C
Response Time 500 ms
Length 254mm
Width 191mm
Height 69mm
Dimensions 254 x 191 x 69mm
Weight 340g
2 現貨庫存,次日發貨。
單價 個
HK$ 1,509.00
(不含稅)
單位
Per unit
1 +
HK$1,509.00