- RS庫存編號:
- 922-6967
- 製造零件編號:
- 278529 FAZ-B6/1
- 製造商:
- Eaton
- RS庫存編號:
- 922-6967
- 製造零件編號:
- 278529 FAZ-B6/1
- 製造商:
- Eaton
法例與合規
產品詳細資訊
Eaton FAZ Series MCBs
Eaton FAZ- miniature circuit breakers are Current limiting design provides fast short-circuit interruption that reduces the let-through energy that can damage the circuit, Trip-free design. Breaker cannot be defeated by holding the handle in the ON position
Features and Benefits
Thermal-magnetic overcurrent protection
Power to the circuit breakers can be fed from the line or load side
Clear indication of contact position via front switch toggle
Easy installation on DIN rail. Module width of only 17.5 mm (per pole)
Six levels of short-circuit protection, categorized by B, C, D, K, S and Z curves
Small modular width of the device and accessories saves space in the panel or equipment, which can lead to cost savings
Dual rated for IEC 60947-2 standard
Module widths: 1 Pole 17.5mm, 2 pole 35mm and 3 pole 52.5mm
Power to the circuit breakers can be fed from the line or load side
Clear indication of contact position via front switch toggle
Easy installation on DIN rail. Module width of only 17.5 mm (per pole)
Six levels of short-circuit protection, categorized by B, C, D, K, S and Z curves
Small modular width of the device and accessories saves space in the panel or equipment, which can lead to cost savings
Dual rated for IEC 60947-2 standard
Module widths: 1 Pole 17.5mm, 2 pole 35mm and 3 pole 52.5mm
Standards
IEC 60947-2 Relates to Low Voltage Circuit Breakers for use in industrial and similar
Installations. In the UK traditionally known as moulded case circuit breakers
(MCCBs) and also air circuit breakers (ACBs).
Installations. In the UK traditionally known as moulded case circuit breakers
(MCCBs) and also air circuit breakers (ACBs).
Q: What is the differences in the Tripping Curves B, C, D and S?
A: Curve B: Tripping: 3 to 5 times the rated current.
Applications: protection of generators, persons, very long cables
Curve C: Tripping: 5 to 10 times the rated current
Applications: protection of circuits and general applications
Curve D: Tripping: 10 to 14 times the rated current
Curve S Tripping 13 to 17 times the rated current
Suitable for applications where high levels of inrush current are expected. Instantaneous trip is 13–17X rating of device (In). The high magnetic trip point prevents nuisance tripping in high inductive applications such as motors, transformers and power supplies
Standards
IEC 898; BS/EN60-898; EN50 022/DIN46277-3 (BS5584).
FAZ-C*/* & FAZ-S*/* = IEC/EN60947-2
FAZ-C*/* & FAZ-S*/* = IEC/EN60947-2
Eaton xEffect MCB Mini Circuit Breaker, 240V, 6A - FAZ Series - 278529 FAZ-B6/1
Choose this general-purpose mini circuit breaker (MCB) from Eaton's xEffect range to protect your equipment from overvoltage and short circuits. The component is designed for low-voltage applications and works by cutting off the power supply to the circuit or machine when a fault occurs. As this MCB has compact dimensions of 80mm height and 17.5mm width, it's a good fit for setups with limited space. You can't access its terminals with your fingers, so there's no risk of electric shock. You'll find this component used in electrical distribution boards and machine control panels.
Features & Benefits
IP40 (ingress protection) rating indicates protection from solid objects over 1mm in size, such as wires and nails
Can function with both alternating current (AC) and direct current (DC) voltage supplies for versatile use
Simple snap-fit DIN rail mounting doesn't need any tools for installation
Electrical life of 10,000 operations for reliable long-term performance
Can function with both alternating current (AC) and direct current (DC) voltage supplies for versatile use
Simple snap-fit DIN rail mounting doesn't need any tools for installation
Electrical life of 10,000 operations for reliable long-term performance
What is overcurrent?
Overcurrent occurs when the rated current is more than the current capacity of the circuit. This can cause damage to the circuit which creates a risk of fire.
Note
Eaton formerly known as Moeller
規格
Attribute | Value |
---|---|
Number of Poles | 1P |
Current Rating | 6A |
Tripping Characteristics | Type B |
Rated AC Voltage | 240V |
Rated DC Voltage | 48V |
Breaking Capacity at Maximum Voltage Rating | 10 kA |
Range | xEffect |
Series | Eaton Moeller |
Circuit Breaker Type | MCB |
Width | 66mm |
Length | 17.8mm |
Mounting Style | DIN Rail Mount |
Depth | 80mm |
Reset Actuator Type | Toggle Switch |
Terminal Contact Type | Screw |
Tripping Mechanism | Thermal-Magnetic |
Break Time | Instantaneous |