![]() RoHS Certificate of Compliance EU Directives 2011/65/EU and 2015/863 restrict the use of the 10 substances below in the manufacture of specified types of electrical equipment. The restricted substances and maximum allowed concentrations in the homogenous material are, by weight:Whilst this restriction does not legally apply to components, it is recognised that component “compliance” is relevant to many customers. RS definition of RoHS Compliance:
The supplier of the item listed below has informed RS Components that the product is “RoHS Compliant”. RS Components has taken all reasonable steps to confirm this statement. Information relates only to products sold on or after the date of this certificate. Compliant product details |
|||||||||||||||||||||||
Order Code | 731-8951 | ||||||||||||||||||||||
Description | Schneider Electric 24 V ac/dc Safety Relay With 2 Safety Contacts and 1 Auxilary Contact | ||||||||||||||||||||||
Manufacturer/Brand Name | Schneider Electric | ||||||||||||||||||||||
Manufacturer Part No. | XPSBCE3110P | ||||||||||||||||||||||
|
731-8951 | |
Schneider Electric 24 V ac/dc Safety Relay With 2 Safety Contacts and 1 Auxilary Contact | |
Schneider Electric | |
XPSBCE3110P |
日期 | Dec 11, 2019 |
Incorporates relay outputs for two hand control applications
Compact and robust design
The enclosure has a protection class rating of IP40 and the terminals are protected to IP20
To initiate a dangerous movement, both operators (two-hand control pushbuttons) must be activated within an interval of less than 0.5 s (synchronous activation)
Three LEDs to indicate control/fuse supply, feedback loop and safety output contact status
PL e/Category 4 conforming to EN/ISO 13849-1, SILCL 3 conforming to EN/IEC 62061
Cage clamp and pluggable versions are available
UL, CSA, BG
Attribute | Value |
---|---|
Supply Voltage | 24 V ac/dc |
Auxiliary Contacts | 1 |
Function | Two-Hand Control |
Safety Contacts | 2 |
Range | Preventa |
Terminal Type | Screw |
Width | 22.5mm |
Length | 99mm |
Depth | 114mm |