- RS庫存編號:
- 134-8662
- 製造零件編號:
- A9MEM1541
- 製造商:
- Schneider Electric
當前暫無庫存,可於2024/6/25發貨,3 工作日送達。
已增加
單價 个
HK$5,030.82
單位 | Per unit |
1 + | HK$5,030.82 |
Better World
我們的 Better World 產品系列可讓您輕鬆選擇值得信賴的環保產品。 點擊此處了解更多。
- RS庫存編號:
- 134-8662
- 製造零件編號:
- A9MEM1541
- 製造商:
- Schneider Electric
法例與合規
產品詳細資訊
Acti9 PowerTag Energy Sensor
The Acti 9 Smartlink system is used to monitor the final distribution boards to any supervision system.
Modular Acti 9 devices in the Acti 9 Smartlink system are used to monitor, and measure the electrical distribution boards via a Modbus TCP/IP communication network.
The Acti 9 Smartlink system collects the data from electrical distribution boards in real time, thus contributing to achieve efficiency targets or monitoring final loads.
Modular Acti 9 devices in the Acti 9 Smartlink system are used to monitor, and measure the electrical distribution boards via a Modbus TCP/IP communication network.
The Acti 9 Smartlink system collects the data from electrical distribution boards in real time, thus contributing to achieve efficiency targets or monitoring final loads.
The system consists of:
Acti 9 Smart Link SI D.
PowerTag energy sensors (A9MEM1520, A9MEM1521, A9MEM1522, A9MEM1540, A9MEM1541 and A9MEM1542) are the wireless devices that are directly mounted on a circuit breaker and are connected to Acti 9 Smartlink SI D through wireless communication. The circuit breaker auxiliary allows you to monitor the devices and collects not only energy, but also power and alarm events on the voltage loss. PowerTag energy sensors are mounted upstream or downstream of Acti 9 circuit breaker or Multi 9 circuit breaker.
Pre-wired cables.
PowerTag energy sensors (A9MEM1520, A9MEM1521, A9MEM1522, A9MEM1540, A9MEM1541 and A9MEM1542) are the wireless devices that are directly mounted on a circuit breaker and are connected to Acti 9 Smartlink SI D through wireless communication. The circuit breaker auxiliary allows you to monitor the devices and collects not only energy, but also power and alarm events on the voltage loss. PowerTag energy sensors are mounted upstream or downstream of Acti 9 circuit breaker or Multi 9 circuit breaker.
Pre-wired cables.
The system offers the following advantages and services:
Calculation functions
Telemetering applications
Monitor load unbalance
Monitor power and voltage loss
Energy management and regulations
Telemetering applications
Monitor load unbalance
Monitor power and voltage loss
Energy management and regulations
Acti 9 Smartlink SI D is a wireless connection to Modbus TCP/IP concentrator.
規格
Attribute | Value |
---|---|
Manufacturer k.i.m. | Schneider Electric |
Supply Voltage | 415V ac |
Mounting Type | Plug-On Mount |
Minimum Operating Temperature | -25°C |
Depth | 42.6mm |
Maximum Operating Temperature | +60°C |
Power Consumption | 1VA |
Better World Verification | Green Premium |
Range | Acti 9 |
Better World Product | Yes |
Height | 16.5mm |
Width | 72mm |
Current Rating | 63A |
IP Rating | IP20 |
Wired/Wireless | Wireless |
For Use With | Acti 9 iC65, Acti 9 iID, Acti 9 iID K, Acti 9 iK60, Acti 9 iKQ, Acti 9 iKQE RCBO, Acti 9 K60, Acti 9 Reflex iC60, Acti 9 Single Terminal iC60, Multi 9 C32N, Multi 9 C60, Multi 9 C65, Multi 9 ID |