Chauvin Arnoux L261 Voltage Data Logger, Maximum Voltage Measurement 600V ac/dc, USB 2.0, Battery Powered

產品概覽和技術數據資料表
法例與合規
相容
COO (Country of Origin): US
產品詳細資訊

Simple Logger® II TRMS 600 V AC/DC Model L261

TRMS Voltage data logger suitable for the following applications:
Surge and Sag recording
Long-term supply monitoring
Industrial, commercial and residential monitoring
Monitor voltage harmonics
Find intermittent voltage problems
Machine monitoring

TRMS voltage recording up to 600 V AC/DC
64 samples per cycle
Programmable storage rates from 8 per second to 1 per day
3 user-selectable storage modes
Stores up to 240,000 measurements in nonvolatile memory
Powered by standard alkaline batteries
Lightweight, compact, fits anywhere
5 LED indicators display logger status quickly and clearly
Includes FREE DataView® software for data storage, real-time waveform display, analysis and report generation
Isolated USB communication
USB cable included
300 V CAT IV; 600 V CAT III

Supplied with

Model L261 includes type A to 5-pin mini-B USB 2metres, set of two colour-coded 1.5 m (5 ft) voltage leads, colour-coded crocodile clips (red/black), DataView® CD, two 1.5 V AA-cell alkaline batteries and user manual.

Chauvin Arnoux

規格
Attribute Value
Measurement Parameters Voltage
Number of Input Channels 1
Interface Type USB 2.0
Maximum Voltage Measurement 600V ac/dc
Power Source Battery
IP Rating IP40
Minimum Operating Temperature -10°C
Maximum Operating Temperature +50°C
Display Type LED
Best Voltage Measurement Accuracy ±0.5 % + 0.5V
Includes AA Battery x 2, DataView CD, USB Cable, User Manual
Battery Life Up to 45 days
Battery Type AA x 2
Dimensions 125 x 70 x 32mm
Number of Readings Per Channel 240000