TRACOPOWER TEL 3 DC-DC Converter, ±15V dc/ ±100mA Output, 4.5 → 9 V dc Input, 3W, Through Hole, +85°C Max Temp
- RS庫存編號:
- 396-5130P
- 製造零件編號:
- TEL 3-0523
- 製造商:
- TRACOPOWER
可享批量折扣
單價 个 (以每管裝提供)**
HK$118.80
當前暫無庫存,可於2025/3/11發貨,3 工作日送達。*
* 交貨日期可能會根據您選擇的數量和交貨地址而變更。
訂單金額滿 HK$850.00 即可享受 免費 送貨服務
單位 | 每單位 |
---|---|
3 - 4 | HK$115.80 |
5 + | HK$114.10 |
** 參考價格
- RS庫存編號:
- 396-5130P
- 製造零件編號:
- TEL 3-0523
- 製造商:
- TRACOPOWER
Traco 3W DIP Single/Dual Output Regulated Isolated DC-DC Converter - TEL-3 Series
The Traco Power TEL-3 series is a range of isolated, 3 Watt, DC-DC converters in a DIP-24 package. With their high efficiency these regulated converters allows operation temperature up to 71°C at full load and low output noise. The TEL-3 series feature wide input range and tightly regulated output voltage, which qualifies these DC-DC converters for many cost critical applications in industrial and consumer electronics.
Wide 2:1 and 3:1 input range
High efficiency up to 81%
DIL-24 plastic package
Indefinite short-circuit protection
I/O isolation 1500 VDC
Available with industry standard pinout (NP)
Operating temperature range –40°C to +85°C
High efficiency up to 81%
DIL-24 plastic package
Indefinite short-circuit protection
I/O isolation 1500 VDC
Available with industry standard pinout (NP)
Operating temperature range –40°C to +85°C
Standards
UL 60950-1, IEC/EN 60950-1
Approvals
UL, cUL, EN, IEC, CSA File No. 226037
TRACOPOWER TEL 3 Series DC-DC Converter, ±15V DC Output Voltage, 3W Power Rating - TEL 3-0523
This isolated DC-DC converter offers efficient voltage regulation for a variety of applications. It transforms low input voltages from 4.5V to 9V DC into a stable output of ±15V DC, catering to professionals in automation and electronics. With a power rating of 3W, this compact converter is suitable for powering sensitive electronic devices where consistent voltage is essential.
Features & Benefits
• Provides stable output voltage with ±1% load regulation
• Achieves up to 74% efficiency
• Compact size facilitates integration into limited spaces
• Features a 1.5 kV isolation voltage for enhanced safety
• Operates effectively in temperatures ranging from -40 to +85°C
• Through-hole mounting type allows for easy installation
• Achieves up to 74% efficiency
• Compact size facilitates integration into limited spaces
• Features a 1.5 kV isolation voltage for enhanced safety
• Operates effectively in temperatures ranging from -40 to +85°C
• Through-hole mounting type allows for easy installation
Applications
• Suitable for industrial automation systems
• Applicable in telecommunications equipment
• Ideal for instrumentation and measurement devices
• Supports various electronic in the medical field
• Utilised in control systems for machinery and robotics
• Applicable in telecommunications equipment
• Ideal for instrumentation and measurement devices
• Supports various electronic in the medical field
• Utilised in control systems for machinery and robotics
What is the maximum input voltage for this unit?
The maximum input voltage for proper operation is 9V DC.
Can it be used in outdoor applications?
It is recommended for indoor use, as exposure to extreme conditions may impact performance.
How does it handle voltage fluctuations?
It ensures consistent output voltage even with varying input voltages.
What kind of load can it support?
It can support a load of up to ±100mA without experiencing performance issues.
Is installation straightforward?
Yes, the through-hole mounting type simplifies the installation process.
For products that are Customized and under Non-cancellable & Non-returnable, Sales & Conditions apply.
Approvals
UL Recognised; EN60950; UL1950
Attribute | Value |
---|---|
Output Voltage | ±15V dc |
Input Voltage Range | 4.5 → 9 V dc |
Power Rating | 3W |
Input Voltage Nominal | 5 V dc |
Output Current | ±100mA |
Mounting Type | Through Hole |
Isolated | Yes |
Number of Outputs | 2 |
Package | DIP 24 |
Isolation Voltage | 1.5kV dc |
Length | 31.8mm |
Depth | 10.2mm |
Width | 20.3mm |
Railway Approved | No |
Series | TEL 3 |
Load Regulation | ±1% |
Efficiency | 74% |
Medical Approved | No |
Standards Met | IEC/UL 60950-1 |
Maximum Temperature | +85°C |
Minimum Temperature | -40°C |
- COO (Country of Origin):
- TW