Parker UCC Easiflow Series Variable Area Flow Meter for Liquid, 4 L/min Min, 50 L/min Max
- RS庫存編號:
- 186-0055
- 製造零件編號:
- EF.7731112291
- 製造商:
- Parker UCC
可享批量折扣
小計(1 件)*
HK$4,037.20
訂單超過 HK$250.00 免費送貨
有庫存
- 5 件準備從其他地點送貨
- 加上 2 件從 2026年1月09日 起發貨
- 加上 6 件從 2026年1月16日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 - 5 | HK$4,037.20 |
| 6 + | HK$3,872.40 |
* 參考價格
- RS庫存編號:
- 186-0055
- 製造零件編號:
- EF.7731112291
- 製造商:
- Parker UCC
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Parker UCC | |
| Media Monitored | Liquid | |
| Device Type | Variable Area | |
| Minimum Flow Rate | 4 L/min | |
| Maximum Flow Rate | 50 L/min | |
| Supply Voltage | 240 V ac | |
| Pipe Diameter Range | 1 in | |
| Connection Type | 1 BSP Female | |
| Maximum Pressure | 10bar | |
| Material | PET | |
| Minimum Operating Temperature | +5°C | |
| Maximum Operating Temperature | +60°C | |
| Series | Easiflow | |
| 選取全部 | ||
|---|---|---|
品牌 Parker UCC | ||
Media Monitored Liquid | ||
Device Type Variable Area | ||
Minimum Flow Rate 4 L/min | ||
Maximum Flow Rate 50 L/min | ||
Supply Voltage 240 V ac | ||
Pipe Diameter Range 1 in | ||
Connection Type 1 BSP Female | ||
Maximum Pressure 10bar | ||
Material PET | ||
Minimum Operating Temperature +5°C | ||
Maximum Operating Temperature +60°C | ||
Series Easiflow | ||
豁免
- COO (Country of Origin):
- GB





Parker UCC Flowmeter
The Parker UCC Easiflow series variable area flowmeter measures a liquid flow rate of 4L/min to 50L/min. This flowmeter enabled with an AC-DC switch. It is suitable for controlling valves or pump motors or for activating alarm signals. This indicator has an operating voltage of 300VAC/DC.
Note:
The switch is non-latching. Once the flow rate has passed the switching level, it will de-activate. If latching is required, a separate circuit containing a latching relay is necessary. All units are supplied with instruction leaflets.
Inclusions:
2 x DIN standard sockets complete with plugs.
Note:
The switch is non-latching. Once the flow rate has passed the switching level, it will de-activate. If latching is required, a separate circuit containing a latching relay is necessary. All units are supplied with instruction leaflets.
Inclusions:
2 x DIN standard sockets complete with plugs.
Features and Benefits
Pipe diameter range is 1in
Connection type is 1 BSP female
Maximum operating pressure is 10bar
Maximum operating temperature is 60°C
Media monitored is liquid
It works in any plane
Pressures up to 10bar
Accuracy ±5% FSD
Repeatability ±1% FSD
Fully adjustable flow rate signalling
Plant and equipment protection
Connection type is 1 BSP female
Maximum operating pressure is 10bar
Maximum operating temperature is 60°C
Media monitored is liquid
It works in any plane
Pressures up to 10bar
Accuracy ±5% FSD
Repeatability ±1% FSD
Fully adjustable flow rate signalling
Plant and equipment protection
相关链接
- Parker UCC Easiflow Series Variable Area Flow Meter for Liquid 100 L/min Max
- Parker UCC Easiflow Series Variable Area Flow Meter for Liquid 15 L/min Max
- Parker Easiflow Series Variable Area Flow Meter for Liquid 30 L/min Max
- Parker UCC Flowline Series Variable Area Flow Meter for Liquid 20 L/min Max
- Parker UCC Flowline Series Variable Area Flow Meter for Liquid 55 L/min Max
- Parker UCC Flowline Series Variable Area Flow Meter for Liquid 9 L/min Max
- Parker S Series Variable Area Flow Meter for Liquid 10 L/min Max
- Parker S Series Variable Area Flow Meter for Liquid 0.55 L/min Max
