SICK FTS Series Digital Flow Sensor for Liquid
- RS庫存編號:
- 285-1316
- 製造零件編號:
- FTS-H100F04A
- 製造商:
- SICK
Price 个**
HK$3,943.10
當前暫無庫存,可於2025/2/14發貨,4 工作日送達。*
* 交貨日期可能會根據您選擇的數量和交貨地址而變更。
訂單金額滿 HK$850.00 即可享受 免費 送貨服務
單位 | 每單位 |
---|---|
1 + | HK$3,943.10 |
** 參考價格
- RS庫存編號:
- 285-1316
- 製造零件編號:
- FTS-H100F04A
- 製造商:
- SICK
- COO (Country of Origin):
- DE
Overview
The T-Easic® FTS thermal flow sensor measures flow and temperature of liquids in accordance with the calorimetric principle. Available as an industrial variant with VISTAL® housing and display or as a hygienic stainless-steel variant, the T-Easic® FTS is suitable for a wide range of applications. Depending on the requirements, the sensor features two digital outputs for limit value monitoring, a pulse output for volume recording or an analogue output for continuous recording of measured values.
A special feature is integrated empty pipe detection for optimal dry-run protection in pumps. Parameterization can be done via IO-Link or the display. Media taught-in at the factory such as oil and water accelerate commissioning
other liquids can be calibrated quickly and easily.
At a glance
Flow monitoring and temperature measurement in one sensor
Optimized for water and oil
Optimized for water and oil
teach-in option of other liquids
IP 67/IP 69 enclosure rating and IO-Link 1.1
Industrial design in VISTAL® housing with 180°-rotatable OLED display
Stainless steel hygienic variant, completely CIP-/SIP-capable, process temperatures up to 150 °C
IP 67/IP 69 enclosure rating and IO-Link 1.1
Industrial design in VISTAL® housing with 180°-rotatable OLED display
Stainless steel hygienic variant, completely CIP-/SIP-capable, process temperatures up to 150 °C
Your Benefit
One sensor, two measurements – reduces costs and hygiene risk thanks to a unique installation point
Optimal pump protection thanks integrated empty pipe detection
Automated measurement data acquisition via analogue output or IO-Link
Volume recording thanks to configurable pulse output
Cost savings thanks to speedy installation via mounting adapter and T-connectors
Time savings due to easy commissioning without calibration for taught-in media
User friendly industrial version with intuitive menu guidance and display for fast commissioning
Optimal pump protection thanks integrated empty pipe detection
Automated measurement data acquisition via analogue output or IO-Link
Volume recording thanks to configurable pulse output
Cost savings thanks to speedy installation via mounting adapter and T-connectors
Time savings due to easy commissioning without calibration for taught-in media
User friendly industrial version with intuitive menu guidance and display for fast commissioning
Applications
Attribute | Value |
---|---|
Media Monitored | Liquid |
Device Type | Digital |
Supply Voltage | 9 → 30 V dc |
Pipe Diameter Range | 25 mm |
Connection Type | M12 |
Maximum Pressure | 100bar |
Material | Stainless Steel |
Minimum Media Temperature | -40 °C |
Maximum Media Temperature | +150°C |
Minimum Operating Temperature | -40°C |
Series | FTS |
Maximum Operating Temperature | +150°C |
Current Rating | 100 mA |