Calex PC21MT-1 mV Output Signal IR Temperature Sensor, 1m Cable, 0°C to +250°C
- RS庫存編號:
- 553-343
- 製造零件編號:
- PC21MT-1
- 製造商:
- Calex
可享批量折扣
小計(1 件)*
HK$2,131.80
訂單超過 HK$250.00 免費送貨
有庫存
- 3 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 - 5 | HK$2,131.80 |
| 6 + | HK$2,040.30 |
* 參考價格
- RS庫存編號:
- 553-343
- 製造零件編號:
- PC21MT-1
- 製造商:
- Calex
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Calex | |
| Sensor Type | mV Output Signal | |
| Response Time | 240 ms | |
| Accuracy | 1 % | |
| Cable Length | 1m | |
| Supply Voltage | 6 → 28 V dc | |
| Minimum Temperature Sensed | 0°C | |
| Output Type | Analogue | |
| Maximum Temperature Sensed | +250°C | |
| Light Source | Infrared | |
| Housing Material | Stainless Steel 316 | |
| Mounting Type | M16 x 1 mm Thread | |
| Diameter | 18 mm | |
| IP Rating | IP65 | |
| 選取全部 | ||
|---|---|---|
品牌 Calex | ||
Sensor Type mV Output Signal | ||
Response Time 240 ms | ||
Accuracy 1 % | ||
Cable Length 1m | ||
Supply Voltage 6 → 28 V dc | ||
Minimum Temperature Sensed 0°C | ||
Output Type Analogue | ||
Maximum Temperature Sensed +250°C | ||
Light Source Infrared | ||
Housing Material Stainless Steel 316 | ||
Mounting Type M16 x 1 mm Thread | ||
Diameter 18 mm | ||
IP Rating IP65 | ||
- COO (Country of Origin):
- GB
High Performance PyroCouple Series
High quality, low cost, non-contact Infra-red temperature sensors suitable for measuring the temperature of inaccessible or moving objects and materials.
Fast response with high stability
Types available with air/water cooled housings
Quick and easy to install
Available as either two-wire or four-wire units
240 ms to 90% response time
Stainless steel housing
M16 x 1 mm mounting thread
Prewired 1 m cable connection
6 V dc minimum sensor voltage
0.95 emissivity
Temperature change varies by model
Two-wire sensors transmit the target temperature as a 4-20 mA output and offer a simple solution for most non-contact temperature measurement applications.
Four-wire sensors transmit the target temperature as a 0-50 mV or thermocouple output, and in addition transmit the internal temperature as a 4-20 mA output. This second output can be used to ensure that the sensor is being operated within the correct ambient temperature limits and prevent damage caused by overheating or overcooling. It can also be used to give an approximate indication of the air temperature surrounding the sensor.
相关链接
- Calex PC21MT-0 mA Output Signal IR Temperature Sensor 0°C to +250°C
- Calex PC21MT-0WJ mA Output Signal IR Temperature Sensor 0°C to +250°C
- Calex PC21MT-3 Type J Thermocouple IR Temperature Sensor 0°C to +250°C
- Calex PC21MT-4 Type K Thermocouple IR Temperature Sensor 0°C to +250°C
- Calex PC151HT-0 mA Output Signal IR Temperature Sensor 0°C to +500°C
- Calex PC151MT-0 mA Output Signal IR Temperature Sensor 0°C to +250°C
- Calex PC151MT-0WJ mA Output Signal IR Temperature Sensor 0°C to +250°C
- Calex PC21LT-0 mA Output Signal IR Temperature Sensor -20°C to +100°C