ABB S-ARC1 M S-ARC1 M Miniature Circuit Breaker, 1-Pole, 13 A, Type B, 240 V ac AC, 10 kA Breaking Capacity
- RS庫存編號:
- 175-9937
- 製造零件編號:
- 2CSA275901R9135 S-ARC1 M B13
- 製造商:
- ABB
小計(1 件)*
HK$1,663.00
訂單超過 HK$250.00 免費送貨
暫時缺貨
- 從 2026年6月01日 發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | HK$1,663.00 |
* 參考價格
- RS庫存編號:
- 175-9937
- 製造零件編號:
- 2CSA275901R9135 S-ARC1 M B13
- 製造商:
- ABB
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | ABB | |
| Number of Poles | 1 | |
| Product Type | Miniature Circuit Breaker | |
| Tripping Characteristics | Type B | |
| Mount Type | DIN Rail | |
| Breaking Capacity | 10kA | |
| Range | S-ARC1 M | |
| Series | S-ARC1 M | |
| Terminal Type | Cage Terminal | |
| IP Rating | IP40, IP20 | |
| Depth | 69mm | |
| Height | 85mm | |
| Standards/Approvals | IEC/EN 62606, IEC/EN 60898-1 | |
| Tripping Mechanism | Thermal Magnetic | |
| Reset Actuator Type | Toggle Switch | |
| 選取全部 | ||
|---|---|---|
品牌 ABB | ||
Number of Poles 1 | ||
Product Type Miniature Circuit Breaker | ||
Tripping Characteristics Type B | ||
Mount Type DIN Rail | ||
Breaking Capacity 10kA | ||
Range S-ARC1 M | ||
Series S-ARC1 M | ||
Terminal Type Cage Terminal | ||
IP Rating IP40, IP20 | ||
Depth 69mm | ||
Height 85mm | ||
Standards/Approvals IEC/EN 62606, IEC/EN 60898-1 | ||
Tripping Mechanism Thermal Magnetic | ||
Reset Actuator Type Toggle Switch | ||
- COO (Country of Origin):
- IT
ABB S-ARC1 M Series MCB, 1+N Poles, 13A Current Rating - 2CSA275901R9135 S-ARC1 M B13
This MCB is a compact, efficient device designed to ensure reliable circuit protection in electrical installations. With a current rating of 13 A and a unique 1+N configuration, it is suitable for a variety of applications. The circuit breaker has dimensions of 35mm in width and 69mm in depth, making it Ideal for installation on DIN rails, ensuring ease of use and accessibility. Featuring short circuit protection with a breaking capacity of 10 kA, this Type B MCB is essential for modern electrical circuits.
Features & Benefits
• Provides effective short circuit protection to safeguard electrical systems
• Designed with a toggle switch for simple manual reset
• Offers a high breaking capacity of up to 10 kA
• Configured with screw terminals for secure connections
• Operates at a rated AC voltage of 240 V for standard applications
• Compact 35mm width optimises space on DIN rails
• Designed with a toggle switch for simple manual reset
• Offers a high breaking capacity of up to 10 kA
• Configured with screw terminals for secure connections
• Operates at a rated AC voltage of 240 V for standard applications
• Compact 35mm width optimises space on DIN rails
Applications
• Used for protecting residential and commercial circuit installations
• Suitable for electrical projects requiring Type B tripping characteristics
• Ideal for installation in distribution boards for efficient circuit management
• Commonly utilised in automation systems for reliable operation
• Suitable for electrical projects requiring Type B tripping characteristics
• Ideal for installation in distribution boards for efficient circuit management
• Commonly utilised in automation systems for reliable operation
What is the significance of the 1+N configuration in this instance?
The 1+N configuration allows for both live and NEUTRAL protection, which enhances the safety and compliance of the electrical installation, particularly in applications requiring dual pole protection.
How does the tripping characteristic affect its performance?
Type B tripping characteristics are specifically designed to trip at lower overload currents, ensuring sensitive equipment and circuits are promptly protected from excess current.
What benefits do screw terminals provide in this circuit breaker?
Screw terminals offer secure and robust connections, minimising the risk of loose wires, which can lead to overheating or circuit failure, thus enhancing overall safety.
Can this circuit breaker be used in commercial environments?
Yes, it is suitable for both residential and commercial applications, providing reliable protection in various electrical setups, particularly at a 240 V circuit level.
What maintenance is required to ensure the circuit breaker operates effectively?
Regular Visual inspections should be conducted to check for any signs of wear or damage, and operational tests should be performed periodically to ensure the device trips correctly under fault conditions.
相关链接
- ABB S-ARC1 S-ARC1 Miniature Circuit Breaker 13 A 240 V ac AC, 6 kA Breaking Capacity
- ABB S-ARC1 M S-ARC1 M Miniature Circuit Breaker 13 A 240 V ac AC, 10 kA Breaking Capacity
- ABB S-ARC1 M S-ARC1 M Miniature Circuit Breaker 6 A 240 V ac AC, 10 kA Breaking Capacity
- ABB S-ARC1 M S-ARC1 M Miniature Circuit Breaker 16 A 240 V ac AC, 10 kA Breaking Capacity
- ABB S-ARC1 M S-ARC1 M Miniature Circuit Breaker 10 A 240 V ac AC, 10 kA Breaking Capacity
- ABB S-ARC1 M S-ARC1 M Miniature Circuit Breaker 20 A 240 V ac AC, 10 kA Breaking Capacity
- ABB S-ARC1 S-ARC1 Miniature Circuit Breaker 13 A 240 V ac AC, 6 kA Breaking Capacity
- ABB S-ARC1 M S-ARC1 M Miniature Circuit Breaker 6 A 240 V ac AC, 10 kA Breaking Capacity