Druck DPI 615 0bar to 20bar Pressure Calibrator
- RS庫存編號:
- 532-7631
- 製造零件編號:
- I615SPC-13G-4025
- 製造商:
- Druck
單價 个**
HK$84,619.09
可供預購。*
* 交貨日期可能會根據您選擇的數量和交貨地址而變更。
訂單金額滿 HK$850.00 即可享受 免費 送貨服務
單位 | 每單位 |
---|---|
1 + | HK$84,619.09 |
** 參考價格
替代產品
該產品我們目前不提供。 這些是我們推薦的替代產品。
个
HK$45,083.00
个
HK$65,345.11
- RS庫存編號:
- 532-7631
- 製造零件編號:
- I615SPC-13G-4025
- 製造商:
- Druck
Druck Pressure Calibrator - DPI615 - IS, Intrinsically Safe
Druck's DPI615 - IS pressure calibrator is not only portable, easy to use and intrinsically safe, but it is designed for pressure ranges from 2.5 mbar to 700 bar. Druck's range of pressure calibrators are very easy to use, any technician can use the DPI615 calibrator without any previous formal training. The key to the simplicity of use is mainly because of the task-menu, this function allows users to use modes such as P-I, switch test and leak test at the touch of a button. Constructed of a robust, rugged and weather-proof material and design, styled in such a way that the pressure pump can be operated, and test leads connected without compromising the visibility of the large dual parameter display. Featuring a built-in continuity tester and the mA step and ramp outputs contribute to extending the capabilities to include commissioning and maintenance of control loops. Predominantly used for pressure calibration, the DPI615 can be used within a multitude of applications including maintenance and commissioning.
Features & Benefits
These intrinsically safe pressure calibrators are certified to European and North American standards for use in hazardous areas
Ranges between -14.7 to 6000 psi
A task-driven user interface facilitates an easy set-up of calibration, switch testing and leak testing 4 to 20mA simulation, relief valve testing, data logging and ambient temperature recording modes
Pressure range accuracy: ±0.025% full scale of all ranges
Integral combined pressure/vacuum pump
Dual readout: input and output
4-20mA loop test: auto step and ramp
RS232 interface and fully documenting version
Pressure and current displayed simultaneously
Current and voltage measurement
26 Selectable pressure units
Two-way PC communication for transferring procedures and results
Pressure/vacuum pump -850mbar to 20bar
Ranges between -14.7 to 6000 psi
A task-driven user interface facilitates an easy set-up of calibration, switch testing and leak testing 4 to 20mA simulation, relief valve testing, data logging and ambient temperature recording modes
Pressure range accuracy: ±0.025% full scale of all ranges
Integral combined pressure/vacuum pump
Dual readout: input and output
4-20mA loop test: auto step and ramp
RS232 interface and fully documenting version
Pressure and current displayed simultaneously
Current and voltage measurement
26 Selectable pressure units
Two-way PC communication for transferring procedures and results
Pressure/vacuum pump -850mbar to 20bar
Did you know?
The "IS" in the name of a pressure calibrator stands for intrinsically safe, if an item is intrinsically safe it means that it is incapable of releasing sufficient electrical and thermal energy under normal or abnormal conditions. This results in the item not being able to cause ignition of a specific hazardous atmospheric mixture in its most easily ignited concentration.
What's included with this kit?
Batteries
Carrying case
Test leads
User guide
Calibration certificate
Pressure calibrator
Carrying case
Test leads
User guide
Calibration certificate
Pressure calibrator
Group and Category
ll 1 G EEX ia llC T4
Druck Pressure Calibrator, Current Loop Measurement, 300mm Length - I615SPC-13G
This pressure calibrator by Druck offers precise pressure calibration with features such as current loop measurement and ATEX hazardous area certification. With dimensions of 300 x 170 x 140 mm, this instrument is designed for high-pressure measurement applications.
Features & Benefits
• Allows for accurate measurement in a variety of settings
• ATEX hazardous area certification ensures safety in potentially explosive environments
• Leak testing capabilities provide reliable performance for leak testing
• ATEX hazardous area certification ensures safety in potentially explosive environments
• Leak testing capabilities provide reliable performance for leak testing
Applications
• Pressure calibration in industrial automation systems
• Leak testing in mechanical engineering applications
• High-pressure measurement in electronics manufacturing
• Leak testing in mechanical engineering applications
• High-pressure measurement in electronics manufacturing
Can it measure pressure in hazardous areas?
Yes, it is intrinsically safe and ATEX certified for use in hazardous environments.
Will it log data for analysis?
This pressure calibrator comes with data logging capabilities for recording pressure readings.
Is it suitable for leak testing applications?
The instrument is designed for leak testing and offers accurate results.
Attribute | Value |
---|---|
Maximum Pressure Measurement | 20bar |
Minimum Pressure Measurement | 0bar |
Pressure Port Type | Gauge |
Model Number p | DPI 615 |
Data Logging | Yes |
Intrinsically Safe | Yes |
Current Loop Measurement | Yes |
Leak Testing | Yes |
Maximum Operating Temperature | +50°C |
Minimum Operating Temperature | -10°C |
Weight | 3kg |
Dimensions | 300 x 170 x 140mm |
Height | 140mm |
Length | 300mm |
Hazardous Area Certification | ATEX |
Width | 170mm |
不適用
- COO (Country of Origin):
- GB