SICK Inductive Threaded Barrel Proximity Sensor, M8, 2 mm Detection, 2-Wire NO, 10 → 30 V dc
- RS庫存編號:
- 209-3349
- 製造零件編號:
- IME08-02BDSZY2S
- 製造商:
- SICK
小計(1 件)*
HK$413.50
訂單超過 HK$250.00 免費送貨
有庫存
- 7 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | HK$413.50 |
* 參考價格
- RS庫存編號:
- 209-3349
- 製造零件編號:
- IME08-02BDSZY2S
- 製造商:
- SICK
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | SICK | |
| Thread Size | M8 | |
| Sensor Technology | Inductive | |
| Detection Range | 2 mm | |
| Body Style | Threaded Barrel | |
| Output Function | NO | |
| Digital Switching Output Type | 2-Wire | |
| Cable Length | 2m | |
| Connection Type | Pre-Cabled | |
| Supply Voltage | 10 → 30 V dc | |
| IP Rating | IP67 | |
| Length | 52mm | |
| Mounting Type | Flush | |
| Width | 8mm | |
| Housing Material | Brass, Nickel-Plated | |
| Maximum DC Voltage | 30V | |
| Diameter | 8 mm | |
| Minimum Operating Temperature | -25°C | |
| Shielding | Shielded | |
| Maximum Switching Frequency | 4kHz | |
| Switching Frequency | 4 kHz | |
| Reverse Polarity Protection | Yes | |
| Standards Met | CE | |
| Series | IME | |
| Switching Current | 100 mA | |
| Maximum Operating Temperature | +75°C | |
| Short Circuit Overload Protection | Yes | |
| 選取全部 | ||
|---|---|---|
品牌 SICK | ||
Thread Size M8 | ||
Sensor Technology Inductive | ||
Detection Range 2 mm | ||
Body Style Threaded Barrel | ||
Output Function NO | ||
Digital Switching Output Type 2-Wire | ||
Cable Length 2m | ||
Connection Type Pre-Cabled | ||
Supply Voltage 10 → 30 V dc | ||
IP Rating IP67 | ||
Length 52mm | ||
Mounting Type Flush | ||
Width 8mm | ||
Housing Material Brass, Nickel-Plated | ||
Maximum DC Voltage 30V | ||
Diameter 8 mm | ||
Minimum Operating Temperature -25°C | ||
Shielding Shielded | ||
Maximum Switching Frequency 4kHz | ||
Switching Frequency 4 kHz | ||
Reverse Polarity Protection Yes | ||
Standards Met CE | ||
Series IME | ||
Switching Current 100 mA | ||
Maximum Operating Temperature +75°C | ||
Short Circuit Overload Protection Yes | ||
- COO (Country of Origin):
- MY
SICK IME Series Proximity Sensor, 2mm Detection Range, 8mm Thread size - IME08-02BDSZY2S
This proximity sensor is a highly efficient inductive model designed for a range of industrial applications. With a compact M8 threaded barrel design measuring 52mm in length and 8mm in diameter, it features a detection range of 2mm. The sensor operates within a supply voltage of 10 to 30V DC and comes pre-cabled with a 2m length for ease of installation. With an IP67 rating, it is ideal for use in demanding environments.
Features & Benefits
• Inductive technology ensures non-contact object detection
• Compact flush mounting design allows for space-saving installation
• 2-wire configuration simplifies wiring and reduces installation time
• Robust brass, nickel-plated housing provides durability in harsh conditions
• Shielded design prevents interference from external electromagnetic fields
• Reverse polarity and short circuit overload protections enhance safety
• Compact flush mounting design allows for space-saving installation
• 2-wire configuration simplifies wiring and reduces installation time
• Robust brass, nickel-plated housing provides durability in harsh conditions
• Shielded design prevents interference from external electromagnetic fields
• Reverse polarity and short circuit overload protections enhance safety
Applications
• Used for automated assembly line processes
• Ideal for position detection in packaging machinery
• Implemented in material handling systems to ensure precision
• Utilised in factory automation for equipment safety controls
• Effective in robotics for accurate object detection and response
• Ideal for position detection in packaging machinery
• Implemented in material handling systems to ensure precision
• Utilised in factory automation for equipment safety controls
• Effective in robotics for accurate object detection and response
What is the operating temperature range for this sensor?
The sensor operates effectively between -25 °C and +75 °C, ensuring functionality in various temperature conditions commonly encountered in industrial settings.
How does the flush mounting capability benefit installation?
Flush mounting allows the sensor to be integrated seamlessly into equipment, saving space and providing easy access for maintenance while preventing interference with other components.
What types of wiring are recommended for optimal performance?
Using standardised 2-wire cabling is recommended to maintain the efficiency of the sensor, ensuring stable performance within the specified voltage range.
Can this sensor be used in outdoor environments?
While designed for robust performance, ensure that it is installed in locations that provide adequate protection against extreme weather conditions, despite its IP67 rating.
Note
Product details cover the whole product family. For details on the specifications for this individual product, please refer to the datasheet.
相关链接
- SICK Inductive Threaded Barrel Proximity Sensor 2 mm Detection 10 → 30 V dc
- SICK Inductive Threaded Barrel Proximity Sensor 2 mm Detection 10 → 30 V dc
- SICK Inductive Threaded Barrel Proximity Sensor 2 mm Detection 10 → 30 V dc
- SICK Inductive Threaded Barrel Proximity Sensor 4 mm Detection 10 → 30 V dc
- SICK Inductive Threaded Barrel Proximity Sensor 3 mm Detection 10 → 30 V dc
- SICK Inductive Threaded Barrel Proximity Sensor 4 mm Detection 10 → 30 V dc
- SICK Inductive Threaded Barrel Proximity Sensor 4 mm Detection 10 → 30 V dc
- SICK Inductive Threaded Barrel Proximity Sensor 3 mm Detection 10 → 30 V dc
