Castle Sonus GA116L Class 1 Datalogging Sound Level Meter, 30dB to 140dB, 20kHz max
- RS庫存編號:
- 909-3749
- 製造零件編號:
- 01GA116L
- 製造商:
- Castle
單價 个**
HK$14,805.60
當前暫無庫存,可於2025/1/10發貨,3 工作日送達。*
* 交貨日期可能會根據您選擇的數量和交貨地址而變更。
訂單金額滿 HK$850.00 即可享受 免費 送貨服務
單位 | 每單位 |
---|---|
1 + | HK$14,805.60 |
** 參考價格
- RS庫存編號:
- 909-3749
- 製造零件編號:
- 01GA116L
- 製造商:
- Castle
- COO (Country of Origin):
- GB
Castle GA116L Sonus Class 1 Data-logging Sound Level Meter
Castle GA116L is designed for industrial safety officers and safety managers, for compliance with The Control of Noise at Work regulations 2005. It is fully compliant with European and International standards. The GA257L is supplied with dBdataPro LITE PC software for downloading data from the instrument.
Multiple file saving using on board Flash memory
Dual channel measurements for Lp, Leq and Lmax
Simultaneous measurement of Lp, Leq, Lmax, Apeak or Cpeak or Zpeak, Lep,d, LAE, Dose, Dose / Hour, Pa2H, L10, L90 and L(user)
Channel independent Frequency weighting selection A, C or Z
Channel independent Time weighting selection Slow, Fast or Impulse
Sound pressure (Lp) to 0.1dB resolution
Integrated equivalent level (Leq) measurement
Personal sound exposure level (Lep,d)
Single event sound exposure level (LAE)
Percentile levels (L10, L90 and a user selectable level)
Noise dose%, noise dose per hour%, pascal squared hours
Lmax - maximum Lp (rms) level
Apeak, Zpeak or Cpeak – maximum Frequency weighted peak level
Elapsed time (running time hrs, min, sec)
Interval period
Over Load and Under Range indication
Housed in tough, crack-resistant ABS plastic
Dual channel measurements for Lp, Leq and Lmax
Simultaneous measurement of Lp, Leq, Lmax, Apeak or Cpeak or Zpeak, Lep,d, LAE, Dose, Dose / Hour, Pa2H, L10, L90 and L(user)
Channel independent Frequency weighting selection A, C or Z
Channel independent Time weighting selection Slow, Fast or Impulse
Sound pressure (Lp) to 0.1dB resolution
Integrated equivalent level (Leq) measurement
Personal sound exposure level (Lep,d)
Single event sound exposure level (LAE)
Percentile levels (L10, L90 and a user selectable level)
Noise dose%, noise dose per hour%, pascal squared hours
Lmax - maximum Lp (rms) level
Apeak, Zpeak or Cpeak – maximum Frequency weighted peak level
Elapsed time (running time hrs, min, sec)
Interval period
Over Load and Under Range indication
Housed in tough, crack-resistant ABS plastic
Standards
IEC 61672-1:2002 Class 1, IEC 60651: 1979 Type 1, IEC 60804: 2001 Type 1
Supplied with
dBdataLITE PC software
Castle Sonus L, Class 1 Noise at Work Sound Level Meter
Castle SONUS L (GA116L) is a Class 1 sound level meter and is designed for industrial safety officers and safety managers, for compliance with The Control of Noise at Work regulations 2005. It is fully compliant with European and International standards. The SONUS is supplied with dBdata LITE PC software for downloading data from the instrument. This can be upgraded to dBDataPro, with enhanced data manipulation and reporting features.
Multiple file saving using on board Flash memory
Dual channel measurements for Lp, Leq and Lmax
Simultaneous measurement of Lp, Leq, Lmax, Apeak or Cpeak or Zpeak, Lep,d, LAE, Dose, Dose / Hour, Pa2H, L10, L90 and L(user)
Channel independent Frequency weighting selection A, C or Z
Channel independent Time weighting selection Slow, Fast or Impulse
Housed in tough, crack-resistant ABS plastic
Dual channel measurements for Lp, Leq and Lmax
Simultaneous measurement of Lp, Leq, Lmax, Apeak or Cpeak or Zpeak, Lep,d, LAE, Dose, Dose / Hour, Pa2H, L10, L90 and L(user)
Channel independent Frequency weighting selection A, C or Z
Channel independent Time weighting selection Slow, Fast or Impulse
Housed in tough, crack-resistant ABS plastic
The simultaneous measurement of LAeq and LCPeak makes the SONUS L ideal for measurements to The Control of Noise at Work Regulations 2005, which requires both these measurements. The SONUS also simultaneously records the 'A' and 'C' weighted Leq values, which can be used for hearing protection assessments to the regulations. The data logging nature of the instrument allows you to store measurements to later review.
Standards
IEC 61672-1:2002 Class 1, IEC 60651: 1979 Type 1, IEC 60804: 2001 Type 1
Supplied with
dBdataLITE PC software
Standards
IEC 61672-1:2002 Class 1, IEC 60651: 1979 Type 1, IEC 60804: 2001 Type 1
Supplied with
dBdataLITE PC software
Sound pressure (Lp) to 0.1dB resolution
Integrated equivalent level (Leq) measurement
Personal sound exposure level (Lep,d)
Single event sound exposure level (LAE)
Percentile levels (L10, L90 and a user selectable level)
Noise dose%, noise dose per hour%, pascal squared hours
Lmax - maximum Lp (rms) level
Apeak, Zpeak or Cpeak – maximum Frequency weighted peak level
Elapsed time (running time hrs, min, sec)
Interval period
Over Load and Under Range indication
Integrated equivalent level (Leq) measurement
Personal sound exposure level (Lep,d)
Single event sound exposure level (LAE)
Percentile levels (L10, L90 and a user selectable level)
Noise dose%, noise dose per hour%, pascal squared hours
Lmax - maximum Lp (rms) level
Apeak, Zpeak or Cpeak – maximum Frequency weighted peak level
Elapsed time (running time hrs, min, sec)
Interval period
Over Load and Under Range indication
Attribute | Value |
---|---|
Maximum Sound Level | 140dB |
Minimum Sound Level | 30dB |
Resolution | 0.1 dB |
Accuracy Class | IEC 61672-1:2002 Class 1 |
DOSE Measurement | Yes |
Weighting | A, C, Z |
Display Type | LCD |
Battery Type | 9V PP3 |
Fast/Slow Time Averaging | Both |
Data Logging | Yes |
Interface Type | USB |
Maximum Frequency | 20kHz |
Maximum Operating Temperature | +50°C |
Minimum Frequency | 20 Hz |
Model Number p | Sonus GA116L Class 1 |
Minimum Operating Temperature | -10°C |