RTD, TC Temperature Transmitter, 7.5 → 30 V dc

產品概覽和技術數據資料表
法例與合規
相容
COO (Country of Origin): DK
產品詳細資訊

5437 HART 7 Dual Input Temperature Transmitter

PR Electronics 5437 dual input temperature transmitter offers unrivalled performance in the most demanding of applications to convert a wide array of input types to a 4 – 20 mA output signal. The transmitter has 7 input terminals measuring one or two sensors, including two 4-wire RTDs, with individual sensor error detection. Configuring the transmitter with either HART 7 or HART 5 protocols provide flexibility and future proof communication.

Sensor Inputs

The PR 5437 provides unrivalled dual input versatility. Virtually any thermocouple or RTD plus linear resistance up to 100 kΩ, potentiometer, and bipolar mV signals. Input sensor redundancy function maintains process availability and safety by seamlessly switching to backup sensor in the event of primary sensor failure. An alert via HART can be used to allow scheduling of maintenance on the faulty sensor.

Installation Characteristics

Wiring - Innovative housing design means the 5437 temperature transmitter can be wired from either the inside or the outside of the terminals.
1/4” centre hole – A large diameter centre hole for easier installation over a wide range of probe mounting diameters.
Loop test pins - Accessible test pins allow measurement of loop current directly while maintaining loop integrity.
Status LED - On-board LED indicates faults according to NAMUR NE44 and NE107.
Jumper pins - Jumpers allow selection of write protection and transmitter burnout options.

Features and Benefits

• LED provides visual notification of sensor, transmitter, and loop status
• HART 7 and HART 5 communication protocols
• Sensor redundancy function switches to backup sensor in the event of sensor failure
• Sensor drift detection maintains measuring point reliability
• Flexible dual input capability, with choice of output modes
• Superior accuracy ensures true, reliable measurements
• Fast response time easily supports safety and cost-critical applications
• Very low temperature coefficient ensuring maximum accuracy across changing ambient conditions
• High galvanic isolation (2.5 kVAC / 55 VAC) providing protection from ground loops, high voltage transients and common mode interference
• Runtime meters provide a valuable history of the process temperature and the ambient temperature around the transmitter

5437D2

The 5437D can be mounted in zone 0, 1, 2 and zone 20, 21, 22 including M1 / Class I, Division 1, Groups A, B, C, D.

Temperature Transmitters

4 to 20mA loop powered output and reverse polarity protection, configurable without the need for a PC or software

規格
Attribute Value
Input Type Linear Resistance, Potentiometer, RTD, Thermocouple, Voltage
Supply Voltage 7.5 → 30 V dc
Diameter 44 mm
Minimum Temperature Input -200°C
Maximum Temperature Input 850°C
Minimum Operating Temperature -50°C
Maximum Operating Temperature +85°C
Series 5437
Depth 20.2mm
Hazardous Area Certification ATEX
3 現貨庫存,可於4工作日發貨。
單價 個
HK$ 3,736.59
(不含稅)
單位
Per unit
1 +