    Signal conditioners are electronic devices used to modify and optimize electrical signals in various measurement and control systems. They are typically employed in situations where the electrical signals from sensors, transducers, or other sources need to be adjusted or conditioned to meet specific requirements.

    How do Signal Conditioners Work?

    The primary purpose of a signal conditioner is to ensure that the signals are suitable for further processing, transmission, or conversion by other devices or systems. Signal conditioners can perform a variety of functions depending on the specific application.

    What are the types of Signal Conditioning?

    Signal conditioners can be classified into several types based on their specific functions and the signals they process. Here are some common types of signal conditioners: Amplifiers: Amplifiers are signal conditioners used to amplify weak input signals. They increase the signal strength to a level suitable for further processing or transmission. Filters: Signal conditioners that incorporate filters are used to remove unwanted noise or interference from the input signals. Different types of filters, such as low-pass, high-pass, band-pass, or notch filters, are used based on the specific frequency ranges to be filtered. Linearizers: Linearizers are signal conditioners that compensate for nonlinearities in the input signal. They apply mathematical algorithms or lookup tables to linearize the output and provide a more linear response over the measurement range. Isolation Amplifiers: These signal conditioners provide electrical isolation between the input and output sides of a system. They protect sensitive measurement equipment from electrical noise, voltage spikes, and ground loops, ensuring accurate and reliable measurements. Converters: Signal conditioners known as converters are used to convert signals from one form to another. For example, analogue-to-digital converters (ADCs) convert analogue signals into digital form, while digital-to-analogue converters (DACs) convert digital signals into analogue form.

    Where are Signal Conditioners Used?

    Signal conditioners are widely used in industrial automation, process control, data acquisition systems, scientific research, and various other fields where accurate and reliable signal processing is essential. They play a crucial role in optimizing signal quality, reducing noise, and improving the overall performance of measurement and control systems.

    705 產品顯示為 Signal Conditioners

    JM CONCEPT
    Universal Signal Converter
    Current, Voltage, Potentiometer Signal, Resistance, Temperature, Thermocouple
    -
    Current, Voltage, Relay
    Mo, P, PT100, PT1000, TC-B, TC-E, TC-J, TC-K, TC-N, TC-R, TC-S, TC-T, W3/D, W5/C, 0 → 100kohm, 0 → 470ohm, 0-10V, 0-100mv, 0 → 22mA
    -
    22 → 240 V dc, 90 → 230V ac
    -
    DIN Rail
    -10°C
    -10 → +60°C
    +60°C
    -
    -
    ULCOS 900
    WAGO
    Isolation Amplifier
    Current, Voltage
    -
    Current
    0 → 10 V, 0 → 20 mA, 0 → 5 V, 1 → 5 V, 2 → 10 V, 4 → 20mA
    0 → 20 mA, 4 → 20mA
    24V dc
    ATEX, IECEx
    DIN Rail Mount
    -25°C
    -25 → +70°C
    +70°C
    -
    -
    JUMPFLEX
    PR Electronics
    Pulse Isolator
    NAMUR Sensor, Switch
    -
    Relay
    -
    -
    19.2 → 31.2V dc
    ATEX
    -
    -20°C
    -20 → +60°C
    +60°C
    -
    -
    9200
    PR Electronics
    Programmable Transmitter
    Current, RTD, Thermocouple, Voltage
    -
    Current, Voltage, Relay
    -
    -
    19.2 → 300 V dc, 21.6 → 253V ac
    ATEX
    -
    -20°C
    -20 → +60°C
    +60°C
    -
    -
    5100
    Phoenix Contact
    Temperature Converter
    RTD
    -
    Current, Voltage
    0 → 4000 Ω, -200 → +850°C
    0 → 10.5 V, 0 → 24.6mA
    9.6 → 30V dc
    -
    DIN Rail Mount
    -40°C
    -40 → +70°C
    +70°C
    -
    -
    MINI MCR
    SICK
    Signal Converter
    SSI
    -
    Analogue
    4 → 20mA
    0 → 10V
    -
    -
    -
    -
    -
    -
    -
    -
    HN
    Red Lion
    Signal Conditioner Converter
    Current, Linear Resistance, Potentiometer, RTD, Thermocouple, Voltage
    -
    Current, Voltage
    -
    -
    31.2V dc
    ATEX, IECEx
    -
    -
    -
    -
    -
    -
    IAMA
    Phoenix Contact
    Loop Powered Isolator
    Current, Voltage
    -
    Current
    2 mA → 40 mA, 50 mV → 30V
    4 → 20mA
    8 → 30V dc
    ATEX
    DIN Rail Mount
    -40°C
    -40 → +70°C
    +70°C
    -
    -
    MACX MCR
    Schneider Electric
    -
    Current, Voltage
    -
    -
    4 → 20mA
    -
    24V
    IECEx
    Clip-On
    -40°C
    -40 → +80°C
    +85°C
    Yes
    Green Premium
    Harmony Analog
    Weidmüller
    Signal Converter
    Voltage
    -
    Current
    = 28V dc
    60mA
    24V dc
    ATEX, IECEx, SIL
    -
    -
    -
    -
    -
    -
    ACT20X
    Phoenix Contact
    Current Transducer
    Current
    -
    Current
    0 → 12 V ac, 0 → 12A
    0 → 20mA
    24V dc
    -
    -
    -20°C
    -20 → +65°C
    +65°C
    -
    -
    MINI MCR
    PR Electronics
    Converter
    Current, Frequency
    -
    Analogue
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Universal f/I-f/f converter
    Phoenix Contact
    Isolation Amplifier
    Voltage
    -
    Voltage
    -
    -
    19.2 → 30V dc
    -
    DIN Rail
    -20°C
    -20 → +65°C
    +65°C
    -
    -
    3RS7002
    P.M.A
    Universal Signal Converter
    Universal
    -
    Universal
    31 bit, 0 → 100 kHz, 0 → 4500 Ω, -200 → 2315 °C, -3 → 30V
    0 → 10 V, 4 → 20mA
    18 → 30 V ac, 18 → 31V dc
    -
    DIN Rail Mount
    -20°C
    -20 → +60°C
    +60°C
    -
    -
    CI45
    GIC
    Signal Isolator
    Current, Voltage
    -
    Current, Voltage
    0 → 10 V dc, 0 → 20 mA, 2 → 10 V dc, 4 → 20mA
    0 → 10 V dc, 0 → 20 mA, 2 → 10 V dc, 4 → 20mA
    24V dc
    -
    DIN Rail Mount
    -10°C
    -10 → +55°C
    +55°C
    -
    -
    -
    Phoenix Contact
    Interface Converter
    -
    -
    -
    -
    -
    -
    -
    DIN Rail
    -
    -
    -
    -
    -
    -
    PR Electronics
    Frequency Converter
    Frequency
    -
    Current, Voltage, Relay
    0 → 20kHz
    0 → 20mA
    19.2 → 28.8V dc
    -
    DIN Rail Mount
    -20°C
    -20 → +60°C
    +60°C
    -
    -
    5000
    Eaton
    Switch/Proximity Detector
    Current, Voltage
    -
    Current, Voltage
    -
    -
    18 → 32V dc
    -
    DIN Rail Mount
    -20°C
    -20 → +60°C
    +60°C
    -
    -
    MTL
    Weidmüller
    Temperature Converter
    Current, RTD, Thermocouple
    -
    Current
    0 → 20 mA, 4 → 20mA
    0 → 23mA
    19.2 → 31.2V
    IECEx
    DIN Rail Mount
    -20°C
    -20 → +60°C
    +60°C
    -
    -
    ACT20X
    Penko
    Signal Conditioner Amplifier
    Voltage
    -
    Digital
    -
    -
    18 → 32V dc
    -
    -
    -
    -
    -
    -
    -
    SGM700