HellermannTyton, 10 mm Nominal Diameter, Galvanised Steel, Metal
- RS庫存編號:
- 433-480
- 製造零件編號:
- 166-30110
- 製造商:
- HellermannTyton
小計(1 卷,共 10 米)*
HK$280.40
库存信息目前无法访问 - 请稍候查看
卷 | 每卷 | 每米* |
|---|---|---|
| 1 + | HK$280.40 | HK$28.04 |
* 參考價格
- RS庫存編號:
- 433-480
- 製造零件編號:
- 166-30110
- 製造商:
- HellermannTyton
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | HellermannTyton | |
| Product Type | Flexible Conduit | |
| Nominal Diameter | 10mm | |
| Material | Galvanised Steel | |
| Series | SC10 | |
| Colour | Metal | |
| Length | 10m | |
| IP Rating | IP40 | |
| Minimum Operating Temperature | -100°C | |
| Resistance Features | Acid Resistant, Abrasion Resistant, Impact Resistant, High Mechanical Strength, Oil Resistant, Low Toxicity, Low Smoke, Flame Retardant, Sulphur Free | |
| Maximum Operating Temperature | 300°C | |
| Hazardous Area Certification | No | |
| Standards/Approvals | IEC 61386, UL 94 V0, EN IEC 61386, UL 94 HB, UL 94 V2 | |
| Minimum Bend Radius | 25mm | |
| 選取全部 | ||
|---|---|---|
品牌 HellermannTyton | ||
Product Type Flexible Conduit | ||
Nominal Diameter 10mm | ||
Material Galvanised Steel | ||
Series SC10 | ||
Colour Metal | ||
Length 10m | ||
IP Rating IP40 | ||
Minimum Operating Temperature -100°C | ||
Resistance Features Acid Resistant, Abrasion Resistant, Impact Resistant, High Mechanical Strength, Oil Resistant, Low Toxicity, Low Smoke, Flame Retardant, Sulphur Free | ||
Maximum Operating Temperature 300°C | ||
Hazardous Area Certification No | ||
Standards/Approvals IEC 61386, UL 94 V0, EN IEC 61386, UL 94 HB, UL 94 V2 | ||
Minimum Bend Radius 25mm | ||
豁免
HellermanTyton SC10 Series Flexible Conduit, 10mm Nominal Diameter, 10m Length - 166-30110
This flexible conduit provides a metal protective route for cable runs in demanding industrial environments. It is designed to shield wiring from mechanical stress and chemical exposure while maintaining functionality across a wide temperature range. The product is intended for use where a Durable metallic conduit is required to preserve cable integrity and facilitate installation in automation, electrical and mechanical systems.
Features & Benefits
• Galanised steel construction offers enhanced mechanical protection and longevity
• Withstands continuous temperatures up to 300°C for high-heat installations
• Resistant to acids and oils to reduce chemical degradation risk
• Low smoke and sulphur-free composition minimises harmful emissions in fires
• Impact and abrasion resistance reduces maintenance and replacement frequency
• Meets flame-retardant requirements UL94 V0 supporting safer system design
• Withstands continuous temperatures up to 300°C for high-heat installations
• Resistant to acids and oils to reduce chemical degradation risk
• Low smoke and sulphur-free composition minimises harmful emissions in fires
• Impact and abrasion resistance reduces maintenance and replacement frequency
• Meets flame-retardant requirements UL94 V0 supporting safer system design
**Applications**
• Suitable for routing cables in factory automation cabinets and enclosures
• Ideal for protecting harnesses in electrical distribution panels
• Used with sensor and actuator wiring in robotics installations
• Can be used for cable protection where high-temperature exposure occurs
• Suitable for installations requiring reduced-smoke materials in confined spaces
• Ideal for protecting harnesses in electrical distribution panels
• Used with sensor and actuator wiring in robotics installations
• Can be used for cable protection where high-temperature exposure occurs
• Suitable for installations requiring reduced-smoke materials in confined spaces
What ingress protection rating does it provide against solids and liquids?
The conduit carries an IP40 classification which indicates protection against solid objects greater than 1 mm but not against water jets, so additional sealing is needed for wet environments.
How flexible is the conduit for tight routing?
It accommodates bends down to a minimum bend radius of 25 mm, allowing Compact routing while maintaining conductor protection.
Which standards govern its construction and flammability performance?
Manufacturing and dimensional characteristics align with IEC 61386 and EN IEC 61386, while flammability classifications include UL94 V0, UL94 HB and UL94 V2.
What length and internal diameter are supplied for typical installation planning?
Units are supplied in 10 m lengths with a nominal internal diameter of 10 mm to assist in cable planning and run estimates.
相关链接
- HellermannTyton Galvanised Steel, Grey
- HellermannTyton Galvanised Steel, Grey
- HellermannTyton Galvanised Steel, Grey
- HellermannTyton Galvanised Steel, Grey
- HellermannTyton Galvanised Steel, Grey
- HellermannTyton Galvanised Steel, Grey
- HellermannTyton Galvanised Steel, Grey
- HellermannTyton Galvanised Steel, Grey