Eaton Contactor, 230 V ac Coil, 3-Pole, 17 A, 7.5 kW, 1NO, 690 V ac
- RS庫存編號:
- 178-8023
- Distrelec 貨號:
- 301-29-482
- 製造零件編號:
- 277012 DILM17-10(230V50/60HZ)
- 製造商:
- Eaton
Price 个**
HK$673.60
本地庫存暫不足,貨期請向RS查詢
訂單金額滿 HK$850.00 即可享受 免費 送貨服務
單位 | 每單位 |
---|---|
1 + | HK$673.60 |
** 參考價格
- RS庫存編號:
- 178-8023
- Distrelec 貨號:
- 301-29-482
- 製造零件編號:
- 277012 DILM17-10(230V50/60HZ)
- 製造商:
- Eaton
豁免
DILM Contactors, 3 Phase
X Start is the latest generation of Contactors, Overloads and Relays from Moeller, based on the tried and tested DIL series. This generation of modular components benefits from the advances in technology for motor switching and control, which in turn gives the user a number of additional benefits.
Features & Benefits
All the contactors are modular and have a common design
The range is extremely durable, able to handle all demands and features immunity to interference and control circuit reliability-even when used in conjunction with PLCs
Electronic power adjustment of the magnet system on the DC contactors enables very small frame sizes so that AC and DC units now have identical dimensions. This now allows direct arrangement of AC and DC contactors beside each other
The range is extremely durable, able to handle all demands and features immunity to interference and control circuit reliability-even when used in conjunction with PLCs
Electronic power adjustment of the magnet system on the DC contactors enables very small frame sizes so that AC and DC units now have identical dimensions. This now allows direct arrangement of AC and DC contactors beside each other
Typical Applications
Three normally-open main contacts
DC contactors from 12A have an electronic drive that removes the need for coupling relays and all DC contactors up to 150A have a in-built suppressor circuit
Box terminals with double coupling areas gives a guaranteed integrity of connection while wiring different cross-sections and also reduces cabling faults
DC contactors from 12A have an electronic drive that removes the need for coupling relays and all DC contactors up to 150A have a in-built suppressor circuit
Box terminals with double coupling areas gives a guaranteed integrity of connection while wiring different cross-sections and also reduces cabling faults
This range of contactors can be used across a multitude of applications, users will commonly find these contactors being used within industrial settings such as factory automation, railway transportation, electrical systems, electric motor, lighting, and mechanical engineering.
How contactors operate?
Contactors, unlike relays, are specifically designed to connect to high current load devices. Used in larger-scale applications, a contactor is a switch that can be controlled remotely, specifically designed to switch a large amount of electrical power through its contacts. If a device has the ability to switch more than 15 amperes it is called a contactor. These devices also feature high coil voltages which is rare within relays.
Eaton 3-Pole Contactor, 17A, 230V AC Coil - DILM17 Series - 277012 DILM17-10(230V50/60HZ)
Switch your electrical current on and off smoothly with this contactor from Eaton. Specifically designed for high-current load devices, it's commonly used in industrial settings for automation, lighting and machine control systems. The normally open (NO) spring-loaded contact breaks the power supply line when arcing occurs and then turns it back on, minimising motor damage and keeping your system going for longer. Screw the unit onto a DIN rail for a secure fit, even in applications where vibration is expected.
Features & Benefits
• Compatible with the SmartWire-DT communication system for easy wiring
• Operating temperature range of -25°C to +60°C for use in demanding industrial environments
• Can complete up to 5,000 mechanical operations an hour for continuous use
• Mechanical shock resistance to prevent impact damage
• Operating temperature range of -25°C to +60°C for use in demanding industrial environments
• Can complete up to 5,000 mechanical operations an hour for continuous use
• Mechanical shock resistance to prevent impact damage
How does this contactor communicate with its output device?
A direct fieldbus allows this contactor to remotely communication with output devices without the need for individual wired connections.
What's the mechanical lifespan of this contactor?
This contactor has a mechanical lifespan of approximately 10 million operations, so you can rely on it for long-lasting continuous use.
Note
Eaton formerly known as Moeller
Attribute | Value |
---|---|
Coil Voltage | 230 V ac |
Number of Poles | 3 |
Contact Voltage Rating | 690 V ac |
Contact Current Rating | 17 A |
Power Rating | 7.5 kW |
Normal State Configuration | 1NO |
Number Of Auxiliary Contacts | 1 |
Terminal Type | Screw |
Length | 45mm |
Width | 85mm |
Depth | 138mm |
Minimum Operating Temperature | -25°C |
Maximum Operating Temperature | +60°C |
Mounting Style | DIN Rail Mount |
Pole and Throw Configuration | 3P |