Fluke 715 Current & Voltage Calibrator, Max Voltage 20V 20 mA
- RS庫存編號:
- 263-2700
- Distrelec 貨號:
- 176-78-006
- 製造零件編號:
- FLUKE 715
- 製造商:
- Fluke
小計(1 件)*
HK$17,031.90
訂單超過 HK$250.00 免費送貨
製造商存貨
- 準備從 2026年7月15日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | HK$17,031.90 |
* 參考價格
- RS庫存編號:
- 263-2700
- Distrelec 貨號:
- 176-78-006
- 製造零件編號:
- FLUKE 715
- 製造商:
- Fluke
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Fluke | |
| Product Type | Current & Voltage Calibrator | |
| Maximum Voltage Measurement | 20V | |
| Maximum Current Measurement | 20mA | |
| Accuracy | ± 0.01 % | |
| Standards/Approvals | CSA C22.2 No. 1010.1:1992 | |
| Power Source | Battery | |
| Battery Type | Alkaline | |
| Weight | 330g | |
| Height | 201mm | |
| Length | 187mm | |
| Hazardous Area Certification | No | |
| Maximum Operating Temperature | 55°C | |
| Maximum Source Current | 24mA | |
| Minimum Source Voltage | 100mV | |
| Minimum Source Current | 4mA | |
| Minimum Operating Temperature | -10°C | |
| Model Number | 715 | |
| Maximum Source Voltage | 10V | |
| Safety Category Voltage | 30V | |
| Width | 87mm | |
| 選取全部 | ||
|---|---|---|
品牌 Fluke | ||
Product Type Current & Voltage Calibrator | ||
Maximum Voltage Measurement 20V | ||
Maximum Current Measurement 20mA | ||
Accuracy ± 0.01 % | ||
Standards/Approvals CSA C22.2 No. 1010.1:1992 | ||
Power Source Battery | ||
Battery Type Alkaline | ||
Weight 330g | ||
Height 201mm | ||
Length 187mm | ||
Hazardous Area Certification No | ||
Maximum Operating Temperature 55°C | ||
Maximum Source Current 24mA | ||
Minimum Source Voltage 100mV | ||
Minimum Source Current 4mA | ||
Minimum Operating Temperature -10°C | ||
Model Number 715 | ||
Maximum Source Voltage 10V | ||
Safety Category Voltage 30V | ||
Width 87mm | ||
豁免
Fluke Current & Voltage Calibrator, 24mA Maximum Source Current, 10V Maximum Source Voltage - FLUKE 715
This current & voltage calibrator is a compact, battery-powered tool for calibrating and troubleshooting industrial process loops and voltage outputs. It operates across a practical temperature range and is designed for field use where portability, precision and straightforward controls are required.
Features & Benefits
• 0.01% accuracy for precise calibration and verification
• Source and measure 0mA to 20mA or 4mA to 20mA for loop work
• 24mA sourcing capability to simulate over-range conditions
• Voltage sourcing to 10V for transmitter and PLC checks
• Battery operation with removable door for quick replacement
• Safety rating to 30V for safe bench and field checks
• Source and measure 0mA to 20mA or 4mA to 20mA for loop work
• 24mA sourcing capability to simulate over-range conditions
• Voltage sourcing to 10V for transmitter and PLC checks
• Battery operation with removable door for quick replacement
• Safety rating to 30V for safe bench and field checks
**Applications**
• Suitable for commissioning 4mA to 20mA control loops
• Ideal for maintenance of transmitters and PLC outputs
• Used for field verification of loop-powered instruments
• Can be used for sourcing a 24mA fault condition during tests
• Suitable for portable checks where 0.01% accuracy is required
• Ideal for maintenance of transmitters and PLC outputs
• Used for field verification of loop-powered instruments
• Can be used for sourcing a 24mA fault condition during tests
• Suitable for portable checks where 0.01% accuracy is required
What power source does it use and how is it replaced?
It runs on alkaline batteries and has a removable battery door for Rapid changes in the field.
What environmental range can it be used in?
It operates between -10°C and 55°C and survives non‑operating extremes to -4°C and 60°C.
How does it support HART or resistor-requiring loops?
It provides a 24V loop supply while measuring current and can accommodate typical loop resistances when sourcing 24mA.
What are its portability characteristics for site work?
The instrument is lightweight at 330g and housed in a rugged case suitable for handheld use.
Note
Fitting replacement fuse: RS 323-6965
相关链接
- Extech PRC10 Current & Voltage Calibrator, Max Voltage 20V 24 mA
- Extech 412355A Current & Voltage Calibrator, Max Voltage 20V 24 mA
- Time Electronics 1044 Current & Voltage Calibrator, Max Voltage 20V 20 mA
- Chauvin Arnoux CA 1631 Current & Voltage Calibrator, Max Voltage 20V dc 24 mA
- Extech PRC15 Current & Voltage Calibrator, Max Voltage 19.99V 50 mA
- Time Electronics 1030 Current & Voltage Calibrator 100 mA
- Time Electronics 1024 Current & Voltage Calibrator 100 mA
- RS PRO 133 Current & Voltage Calibrator, Max Voltage 24V 24 mA