Megger DET14C Earth Tester 1.5kΩ CAT IV 600 V
- RS庫存編號:
- 705-9422
- 製造零件編號:
- 1000-761
- 製造商:
- Megger
查看所有Earth Testers
- RS庫存編號:
- 705-9422
- 製造零件編號:
- 1000-761
- 製造商:
- Megger
豁免
- COO (Country of Origin):
- GB
法例與合規
豁免
- COO (Country of Origin):
- GB
產品詳細資訊
Megger Earth & Ground Resistance Tester
The Megger earth and ground resistance tester measure a 1.5kΩ absolute maximum resistance and having the CAT IV 600V safety category. This 4-pole earth tester is used to measure soil resistivity and resistance of earth rods and associated installations. It is supplied in a hard carry case together with auxiliary stakes and cables. An ICLAMP selective clamp is available separately and when used with the DET4TC allows the testing of an earth rod without the need to disconnect from the system. A VCLAMP is also available separately, which when used in conjunction with ICLAMP allows stakeless measurements to be made in situations where driving auxiliary stakes is not practical. It has a rechargeable battery-powered 4-terminal tester with selectable test frequencies, greater measurement sensitivity and attached rod technique and stakeless measurement capability.
Features and Benefits
256 test results storage and recall
37mm dia conductor and 50mm earth strap capacity
4 digit plus 6 digit backlit LCD display
Accuracy guaranteed for 50Hz and 60Hz.
Auto ranging and hold function
Extended battery life
Ground resistance range between 0.050Ω and 1500Ω
High and low resistance alarms
Low maintenance flat jaw interface
Maximum current is 100Arms continuous and 200Arms for 60s max at 50Hz and 60Hz
Measurement over the ranges between 16Hz and 400Hz.
Oval clamp for easy access to earth cables and earth straps
Real time date and timestamping of results
True RMS ground leakage current ranges between 0.2 mA and 35A
True RMS readings up to a crest factor of 5.0 (peak current 40A)
37mm dia conductor and 50mm earth strap capacity
4 digit plus 6 digit backlit LCD display
Accuracy guaranteed for 50Hz and 60Hz.
Auto ranging and hold function
Extended battery life
Ground resistance range between 0.050Ω and 1500Ω
High and low resistance alarms
Low maintenance flat jaw interface
Maximum current is 100Arms continuous and 200Arms for 60s max at 50Hz and 60Hz
Measurement over the ranges between 16Hz and 400Hz.
Oval clamp for easy access to earth cables and earth straps
Real time date and timestamping of results
True RMS ground leakage current ranges between 0.2 mA and 35A
True RMS readings up to a crest factor of 5.0 (peak current 40A)
Applications
Buildings, pylons and RF transmitter sites
Lightening protection systems
Lightening protection systems
Certifications
EN 61010-2-032
IEC 61557-13 Class 1
IEC 61557-5
IEC 61557-13 Class 1
IEC 61557-5
規格
Attribute | Value |
Absolute Maximum Resistance Measurement | 1.5kΩ |
Best Accuracy | 1.5 % |
Display Type | LCD |
Safety Category | CAT IV 600 V |
Battery Life | 24 h |
Battery Type | AA |
Power Source | Battery |
Weight | 985g |
Height | 49mm |
Includes | Battery, Calibration Check, Carrying Strap, Case, User Manual |
Length | 248mm |
Maximum Operating Temperature | +50°C |
Measurement Type | Earth Resistance, Leakage Current |
Width | 114mm |
Model Number p | DET14C |