ABB S800S-UC Miniature Circuit Breaker, 4-Pole, 40A, UC-K, 1000 V dc DC, 50 kA Breaking Capacity

小計(1 件)*

HK$14,345.10

Add to Basket
選擇或輸入數量
製造商存貨
  • 準備從 2026年12月08日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +HK$14,345.10

* 參考價格

RS庫存編號:
140-321
製造零件編號:
2CCS864001R1557
製造商:
ABB
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

ABB

Product Type

Miniature Circuit Breaker

Number of Poles

4

Current Rating

40A

Tripping Characteristics

UC-K

Rated DC Voltage

1000V dc

Breaking Capacity

50kA

Series

S800S-UC

Terminal Type

Screw

IP Rating

IP20

Standards/Approvals

IEC/EN 60947-2

Width

106mm

Height

95mm

Depth

82.5mm

Reset Actuator Type

I/O Actuator

COO (Country of Origin):
CH

ABB S800S-UC Series Miniature Circuit Breaker, 40A Current, 1000V rated DC voltage - 2CCS864001R1557


This miniature circuit-breaker is designed to protect DC electrical circuits by interrupting fault currents in industrial installations. It operates with a four-pole configuration and a specific tripping characteristic suited to DC applications, providing controlled disconnection where high DC voltages are present. The device is built for panel or system integration in controlled-environment switchgear where finger-safe protection is required.

Features and Benefits:


• 50kA breaking capacity limits fault energy and protects upstream equipment
• UC-K tripping characteristic provides predictable DC fault response
• Screw terminals enable straightforward secure conductor connections
• Reset I/O actuator allows visible manual switching and resetting
• IP20 enclosure rating ensures Basic finger protection in cabinets

Applications


• Suitable for DC solar array string protection up to 1000V
• Used with industrial control gear requiring four-pole isolation
• Ideal for battery-bank distribution systems
• Can be used for protecting motor-drive DC supply rails
• Used for sectionalising DC busbars in commercial installations

What pole configuration does it provide for isolation?


It provides four poles to isolate all conductors simultaneously for complete circuit disconnection.

How does the device perform under high fault currents?


It interrupts fault currents up to 50kA breaking capacity to reduce thermal and mechanical stress on installations.

What Terminal type is used for conductor attachment?


Screw terminals are provided to secure conductors using standard screw-tightening methods.

What operating control is available for manual intervention?


A reset I/O actuator is fitted to permit manual switching and Visual indication of state.

Which standard governs its design for switching applications?


It is designed to meet the requirements of IEC/EN 60947-2 for low-voltage switching devices.