ABB S800N Miniature Circuit Breaker, 3-Pole, 6A, Type B, 690V ac AC, 690 V DC, 36 kA Breaking Capacity

小計(1 件)*

HK$5,345.10

Add to Basket
選擇或輸入數量
製造商存貨
  • 準備從 2026年12月25日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +HK$5,345.10

* 參考價格

RS庫存編號:
141-004
製造零件編號:
2CCS893001R0065
製造商:
ABB
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

ABB

Number of Poles

3

Product Type

Miniature Circuit Breaker

Current Rating

6A

Tripping Characteristics

Type B

Rated AC Voltage

690V ac

Rated DC Voltage

690V

Breaking Capacity

36kA

Mount Type

DIN Rail

Series

S800N

Terminal Type

Screw

IP Rating

IP20, IP40

Width

81mm

Standards/Approvals

IEC/EN 60947-2IEC/EN 60898-1

Depth

82.5mm

Height

95mm

Tripping Mechanism

Thermal, Electromechanic

Reset Actuator Type

I/O Actuator

COO (Country of Origin):
CH

ABB S800N Series Miniature Circuit Breaker, 6A Current, 690V Rated AC Voltage - 2CCS893001R0065


This miniature circuit breaker provides overcurrent protection for three-pole systems in industrial electrical installations. It is designed for DIN‑rail mounting and interrupts fault currents to protect downstream circuits. The device combines thermal and electromechanical tripping to respond to overloads and short circuits and is suitable for installations requiring recognised international standards.

Features and Benefits:


• 36 kA breaking capacity gives strong fault interruption performance
• Type B tripping provides sensitive protection for low inrush loads
• Thermal electromechanical trip supports both overload and short‑circuit detection
• Screw‑terminal design enables secure conductor connections
• IP20/IP40 ratings permit use in controlled industrial environments

Applications


• Suitable for three‑phase distribution panels in factories
• Ideal for protecting lighting and small motor circuits
• Used with control panels requiring DIN‑rail mounting
• Can be used for modular switchboard protection schemes

What pole configuration does it provide?


It provides a three‑pole arrangement for simultaneous phase disconnection.

How is it mounted within an enclosure?


It clips onto standard DIN‑rail systems for Compact panel installation.

Which tripping behaviours are available for fault conditions?


It uses a combined thermal and electromechanical mechanism to handle overloads and instantaneous faults.

What Terminal connection method is used?


Conductors are secured via screw terminals to ensure firm electrical contact.

What voltage ranges can it handle?


It is rated for operation up to 690 V in AC and DC environments.