ABB S300P Miniature Circuit Breaker, 2-Pole, 16A, Type B, 415V ac AC, 125 V dc DC, 100 kA Breaking Capacity

小計(1 件)*

HK$1,944.80

Add to Basket
選擇或輸入數量
有庫存
  • 3 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +HK$1,944.80

* 參考價格

RS庫存編號:
200-909
製造零件編號:
2CDS382001R0165
製造商:
ABB
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

ABB

Number of Poles

2

Product Type

Miniature Circuit Breaker

Current Rating

16A

Tripping Characteristics

Type B

Rated AC Voltage

415V ac

Rated DC Voltage

125V dc

Mount Type

DIN Rail

Breaking Capacity

100kA

Series

S300P

Terminal Type

Screw

IP Rating

IP20, IP40

Standards/Approvals

UL 489 CSA .. . 5 IECEN 60947

Width

35mm

Depth

69mm

Height

88mm

Reset Actuator Type

Toggle

COO (Country of Origin):
DE

ABB S300P Series Miniature Circuit Breaker, 16A Current, 125V dc Rated Voltage - 2CDS382001R0165


This miniature circuit breaker provides overcurrent protection for low-voltage electrical systems and is designed for rail-mounted installations. It operates across AC and DC supplies and employs a toggle reset for manual reclosing. The device meets recognised international standards and is intended for use where Compact protection and straightforward wiring are required.

Features and Benefits:


• 25kA breaking capacity delivers high fault interruption capability
• Type B tripping offers sensitivity to low-level fault currents
• 2-pole configuration ensures simultaneous disconnection of both conductors
• Screw terminals provide secure conductor retention under vibration
• DIN rail mount enables Rapid panel installation and removal

Applications


• Suitable for control panels in light industrial installations
• Ideal for DC-fed circuits requiring 125V protection
• Used with three-phase distribution up to 415V AC systems
• Can be used for protection of small motor and lighting circuits
• Suitable for modular distribution boards in commercial buildings

What physical mounting method does it require?


It clips onto a standard DIN rail for straightforward panel integration.

How is the breaker manually operated after a trip?


A toggle-style reset actuator allows manual reset without tools.

What ingress protection does the enclosure provide?


It typically offers IP20 protection and IP40 in higher-access-control configurations.

Which Terminal connection type is provided for conductors?


Screw-type terminals are used for conductor termination and clamping.

What tripping characteristic controls its instantaneous behaviour?


A Type B characteristic determines instantaneous trip thresholds for low-level faults.