ABB S300P Miniature Circuit Breaker, 3-Pole, 10A, Type Z, 415V ac AC, 125 V dc DC, 25 kA Breaking Capacity

小計(1 件)*

HK$3,296.90

Add to Basket
選擇或輸入數量
製造商存貨
  • 準備從 2027年1月19日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +HK$3,296.90

* 參考價格

RS庫存編號:
204-275
製造零件編號:
2CDS383001R0428
製造商:
ABB
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

ABB

Product Type

Miniature Circuit Breaker

Number of Poles

3

Current Rating

10A

Tripping Characteristics

Type Z

Rated AC Voltage

415V ac

Rated DC Voltage

125V dc

Mount Type

DIN Rail

Breaking Capacity

25kA

Series

S300P

Terminal Type

Screw

IP Rating

IP20, IP40

Width

52.5mm

Standards/Approvals

ETIM, IEC 60068-2-27, IEC 60898-1, IEC 60947-2, IGCC, NF, REACH, RoHS, UKCA, UL, UNSPSC, WEEE, CE, CMRT, CSA, DNV GL, EAC, eClass, EN45555

Height

88mm

Depth

69mm

Reset Actuator Type

Toggle

COO (Country of Origin):
DE

ABB S300P Series Miniature Circuit Breaker, 10A Current, 125V dc Rated Voltage - 2CDS383001R0428


This miniature circuit breaker is designed to protect three-phase electrical circuits from overcurrent and short-circuit conditions. It fits on DIN-rail systems and uses screw terminals for secure conductor connections. The device operates with Type Z tripping characteristics and incorporates a toggle reset actuator for manual reclose operations.

Features and Benefits:


• 25kA breaking capacity delivers high interrupting performance
• 415V AC rated voltage supports three-phase distribution
• 10A current rating allows precise branch-circuit protection
• Three-pole configuration enables simultaneous phase isolation
• IP20 protection level provides Basic contact safety

Applications


• Suitable for control panels in manufacturing plants
• Ideal for distribution boards in commercial premises
• Used with DC-powered systems up to 125Vdc
• Can be used for motor-feeder protection in factories
• Suitable for retrofit on existing DIN-rail systems

What mounting method is required for installation?


It clips onto standard DIN-rail profiles for straightforward panel mounting.

Which Terminal type is provided for conductor connection?


Screw terminals accept stranded or solid conductors and allow torque-controlled fastening.

How does the tripping characteristic affect sensitivity?


Type Z tripping gives a specific short-time response suited to low inrush applications.

What environmental robustness does the device offer?


The unit meets shock‑resistance standards and provides IP20 access protection.

How is manual resetting performed after fault clearance?


A toggle actuator allows the breaker to be manually reset once the fault is cleared.

相关链接

第一時間了解我們的最新產品和優惠

電郵

您在訂閱此郵件時提供的個人信息將根據《隱私政策》進行處理。