ABB System Pro M Compact S200 M UC Miniature Circuit Breaker, 2-Pole, 5A, Type K, 400V ac AC, 440 V dc DC, 10 kA

小計(1 件)*

HK$2,294.80

Add to Basket
選擇或輸入數量
製造商存貨
  • 準備從 2027年1月18日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +HK$2,294.80

* 參考價格

RS庫存編號:
204-358
製造零件編號:
2CDS272061R0357
製造商:
ABB
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

ABB

Product Type

Miniature Circuit Breaker

Number of Poles

2

Current Rating

5A

Tripping Characteristics

Type K

Rated AC Voltage

400V ac

Rated DC Voltage

440V dc

Mount Type

DIN Rail

Breaking Capacity

10kA

Range

System Pro M Compact

Series

S200 M UC

Terminal Type

Screw

IP Rating

IP20, IP40

Depth

69mm

Height

88mm

Width

35mm

Standards/Approvals

IEC 60068-2-27, IEC/EN 60664-1, UL1077

Reset Actuator Type

Toggle

COO (Country of Origin):
DE

ABB S200 M UC Series Miniature Circuit Breaker, 5A Current, 10kA Breaking Capacity - 2CDS272061R0357


This miniature circuit breaker provides overcurrent protection for DC and AC installations. It is designed for DIN-rail mounting and operates with a Type K trip characteristic to manage selective tripping in mixed-load environments. The device accommodates screw terminations and features a toggle reset actuator for manual reclosure.

Features and Benefits:


• 5 A current rating limits continuous load to the specified amperage
• 10 kA breaking capacity isolates high short-circuit currents
• 440 V DC rated voltage supports DC system protection
• 400 V AC rated voltage handles standard AC distribution
• 2-pole configuration enables simultaneous pole disconnection

Applications


• Suitable for control-panel branch-circuit protection
• Ideal for photovoltaic DC string protection schemes
• Used with industrial machinery auxiliary circuits
• Used for selective protection in mixed AC/DC systems

What mounting method is required for installation?


It clips onto a standard DIN rail for quick panel installation.

Which Terminal type is provided for conductor connection?


Screw terminals are used to secure conductors during wiring.

How does the tripping behaviour affect coordination?


The Type K tripping characteristic offers a defined thermal-magnetic response suitable for inductive loads and coordination with upstream devices.

What ingress protection does it offer for component access?


The device carries IP20 protection for general handling and IP40 where indicated for additional front protection.