ABB S-ARC1 M S-ARC1 M Miniature Circuit Breaker, 1-Pole, 10 A, Type C, 240 V ac AC, 10 kA Breaking Capacity
- RS庫存編號:
- 175-9934
- 製造零件編號:
- 2CSA275901R9104 S-ARC1 M C10
- 製造商:
- ABB
小計(1 件)*
HK$2,078.78
訂單超過 HK$250.00 免費送貨
暫時缺貨
- 從 2026年6月01日 發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | HK$2,078.78 |
* 參考價格
- RS庫存編號:
- 175-9934
- 製造零件編號:
- 2CSA275901R9104 S-ARC1 M C10
- 製造商:
- ABB
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | ABB | |
| Number of Poles | 1 | |
| Product Type | Miniature Circuit Breaker | |
| Tripping Characteristics | Type C | |
| Breaking Capacity | 10kA | |
| Mount Type | DIN Rail | |
| Range | S-ARC1 M | |
| Series | S-ARC1 M | |
| Terminal Type | Cage Terminal | |
| IP Rating | IP20, IP40 | |
| Depth | 69mm | |
| Standards/Approvals | IEC/EN 60898-1, IEC/EN 60947-2 | |
| Height | 85mm | |
| Reset Actuator Type | Toggle Switch | |
| Tripping Mechanism | Thermal Magnetic | |
| 選取全部 | ||
|---|---|---|
品牌 ABB | ||
Number of Poles 1 | ||
Product Type Miniature Circuit Breaker | ||
Tripping Characteristics Type C | ||
Breaking Capacity 10kA | ||
Mount Type DIN Rail | ||
Range S-ARC1 M | ||
Series S-ARC1 M | ||
Terminal Type Cage Terminal | ||
IP Rating IP20, IP40 | ||
Depth 69mm | ||
Standards/Approvals IEC/EN 60898-1, IEC/EN 60947-2 | ||
Height 85mm | ||
Reset Actuator Type Toggle Switch | ||
Tripping Mechanism Thermal Magnetic | ||
- COO (Country of Origin):
- IT
ABB S-ARC1 M Series MCB, 10A Current Rating , 1+N Poles - 2CSA275901R9104 S-ARC1 M C10
This MCB circuit breaker is designed for efficient electrical protection in various applications. The single pole type offers a current rating of 10 A and operates effectively at a rated AC voltage of 240 V. With dimensions of 35mm in width and 69mm in depth, it mounts easily on a DIN rail, ensuring a streamlined installation process. Its robust design is suited for reliable short circuit protection.
Features & Benefits
• Offers short circuit protection for enhanced safety in electrical systems
• Type C MCB ensures suitable tripping characteristics for moderate overloads
• Breaking capacity of 10 kA at maximum voltage rating for reliable performance
• Toggle switch reset actuator simplifies the restoration process after tripping
• Screw Terminal contact type provides secure and stable connections
• Compact design makes it suitable for space constrained environments
• Type C MCB ensures suitable tripping characteristics for moderate overloads
• Breaking capacity of 10 kA at maximum voltage rating for reliable performance
• Toggle switch reset actuator simplifies the restoration process after tripping
• Screw Terminal contact type provides secure and stable connections
• Compact design makes it suitable for space constrained environments
Applications
• Used in residential and commercial electrical systems
• Ideal for automation processes requiring circuit protection
• Suitable for installations needing reliable short circuit security
• Utilised in mechanical for electric motor protection
• Effective in electronics for safeguarding sensitive components
• Ideal for automation processes requiring circuit protection
• Suitable for installations needing reliable short circuit security
• Utilised in mechanical for electric motor protection
• Effective in electronics for safeguarding sensitive components
What are the tripping characteristics and why are they important?
The tripping characteristics are Type C, which allows for moderate overload protection. This is VITAL for applications where transient surges may occur without nuisance tripping, thus protecting equipment effectively.
How does the breaking capacity affect the circuit breaker's performance?
The breaking capacity of 10 kA ensures that it can handle significant fault currents, thereby providing a thorough safeguard against potential electrical faults that could cause system failure or hazards.
What is the significance of using a screw Terminal contact type?
Screw Terminal contacts provide a robust and secure connection, reducing the risk of accidental disconnections and ensuring consistent performance in demanding electrical environments.
Can this be integrated into existing electrical systems easily?
Yes, the Compact design and DIN rail mounting style facilitate integration into existing systems without major modifications, making installation straightforward for both new and retrofit applications.
What environmental factors should be considered during installation?
It is important to consider factors such as temperature, humidity, and potential exposure to dust or moisture. Proper installation in a suitable environment will enhance the lifespan and reliability of the circuit breaker.
相关链接
- ABB S-ARC1 S-ARC1 Miniature Circuit Breaker 10 A 240 V ac AC, 6 kA Breaking Capacity
- ABB S-ARC1 M S-ARC1 M Miniature Circuit Breaker 10 A 240 V ac AC, 10 kA Breaking Capacity
- ABB S-ARC1 M S-ARC1 M Miniature Circuit Breaker 13 A 240 V ac AC, 10 kA Breaking Capacity
- ABB S-ARC1 M S-ARC1 M Miniature Circuit Breaker 6 A 240 V ac AC, 10 kA Breaking Capacity
- ABB S-ARC1 M S-ARC1 M Miniature Circuit Breaker 6 A 240 V ac AC, 10 kA Breaking Capacity
- ABB S-ARC1 M S-ARC1 M Miniature Circuit Breaker 16 A 240 V ac AC, 10 kA Breaking Capacity
- ABB S-ARC1 M S-ARC1 M Miniature Circuit Breaker 16 A 240 V ac AC, 10 kA Breaking Capacity
- ABB S-ARC1 M S-ARC1 M Miniature Circuit Breaker 20 A 240 V ac AC, 10 kA Breaking Capacity
