ABB S-ARC1 M S-ARC1 M Miniature Circuit Breaker, 1-Pole, 10 A, Type C, 240 V ac AC, 10 kA Breaking Capacity

小計(1 件)*

HK$2,078.78

Add to Basket
選擇或輸入數量
暫時缺貨
  • 2026年6月01日 發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +HK$2,078.78

* 參考價格

RS庫存編號:
175-9934
製造零件編號:
2CSA275901R9104 S-ARC1 M C10
製造商:
ABB
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

ABB

Number of Poles

1

Product Type

Miniature Circuit Breaker

Tripping Characteristics

Type C

Breaking Capacity

10kA

Mount Type

DIN Rail

Range

S-ARC1 M

Series

S-ARC1 M

Terminal Type

Cage Terminal

IP Rating

IP20, IP40

Depth

69mm

Standards/Approvals

IEC/EN 60898-1, IEC/EN 60947-2

Height

85mm

Reset Actuator Type

Toggle Switch

Tripping Mechanism

Thermal Magnetic

COO (Country of Origin):
IT

ABB S-ARC1 M Series MCB, 10A Current Rating , 1+N Poles - 2CSA275901R9104 S-ARC1 M C10


This MCB circuit breaker is designed for efficient electrical protection in various applications. The single pole type offers a current rating of 10 A and operates effectively at a rated AC voltage of 240 V. With dimensions of 35mm in width and 69mm in depth, it mounts easily on a DIN rail, ensuring a streamlined installation process. Its robust design is suited for reliable short circuit protection.

Features & Benefits


• Offers short circuit protection for enhanced safety in electrical systems
• Type C MCB ensures suitable tripping characteristics for moderate overloads
• Breaking capacity of 10 kA at maximum voltage rating for reliable performance
• Toggle switch reset actuator simplifies the restoration process after tripping
• Screw Terminal contact type provides secure and stable connections
• Compact design makes it suitable for space constrained environments

Applications


• Used in residential and commercial electrical systems
• Ideal for automation processes requiring circuit protection
• Suitable for installations needing reliable short circuit security
• Utilised in mechanical for electric motor protection
• Effective in electronics for safeguarding sensitive components

What are the tripping characteristics and why are they important?


The tripping characteristics are Type C, which allows for moderate overload protection. This is VITAL for applications where transient surges may occur without nuisance tripping, thus protecting equipment effectively.

How does the breaking capacity affect the circuit breaker's performance?


The breaking capacity of 10 kA ensures that it can handle significant fault currents, thereby providing a thorough safeguard against potential electrical faults that could cause system failure or hazards.

What is the significance of using a screw Terminal contact type?


Screw Terminal contacts provide a robust and secure connection, reducing the risk of accidental disconnections and ensuring consistent performance in demanding electrical environments.

Can this be integrated into existing electrical systems easily?


Yes, the Compact design and DIN rail mounting style facilitate integration into existing systems without major modifications, making installation straightforward for both new and retrofit applications.

What environmental factors should be considered during installation?


It is important to consider factors such as temperature, humidity, and potential exposure to dust or moisture. Proper installation in a suitable environment will enhance the lifespan and reliability of the circuit breaker.