Schneider Electric TeSys TeSys Miniature Circuit Breaker, 3-Pole, 220 A, 690 V ac AC, 70 kA Breaking Capacity

小計(1 件)*

HK$7,693.60

Add to Basket
選擇或輸入數量
有庫存
  • 加上 1 件從 2026年1月26日 起發貨
  • 加上 1 件從 2026年2月06日 起發貨
  • 加上 1 件從 2026年2月20日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +HK$7,693.60

* 參考價格

RS庫存編號:
188-4751
製造零件編號:
GV5P220H
製造商:
Schneider Electric
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Schneider Electric

Product Type

Miniature Circuit Breaker

Number of Poles

3

Current Rating

220 A

Rated AC Voltage

690 V ac

Mount Type

DIN Rail

Breaking Capacity

70kA

Range

TeSys

Series

TeSys

IP Rating

IP20

Depth

161mm

Height

105mm

Width

161 mm

Standards/Approvals

UL 60947-4-1, EN IEC 60947-4-1, EN IEC 60947-1, EN IEC 60947-2, CSA C22.2 No. 60947-4-1

Tripping Mechanism

Thermal Magnetic

Break Time

Instantaneous

Reset Actuator Type

Handle

Schneider Electric TeSys GV5 and GV6 TeSys Giga MCB Motor Circuit Breakers.


The TeSys range of MCB Motor circuit breakers GV5 and GV6, designed to protect motors from overloads, short circuits, phase unbalance and phase loss.

TeSys GV5 and GV6 are now part of the TeSys Giga range of circuit breakers. TeSys GV5 and GV6 are coordinated with TeSys Giga contactors. The TeSys Giga motor circuit breakers will give you even better protection and are perfect for demanding applications, combining advanced electronics and up to date electromechanical technology. Easily installed thanks to universal Screw fixing plus the automatic compensation for temperature changes and international standards compliance this motor circuit breaker provides excellent protection.

TeSys Giga GV5 and GV 6 MCB Features.


  • Choice of 4 x current ratings – 150 A, 220 A, 320 A, 500 A.

  • Advanced Micrologic trip unit (overload, short circuit, Phase loss and unbalance protection).

  • Adjustable overload protection (Ir): 50 to 100% x In, includes trip class selection (Class 5, 10 or 20)

  • Adjustable Short-time protection threshold (Isd): 5 to 13 x In with fixed time delay

  • Short-Circuit instantaneous protection (Ii): 15 x In (max rating of the trip unit)

  • Front LED indications: Green LED for pre-alarm before event of fault and Red LED for motor operation

  • Suitable for isolation, as per IEC standards

  • Control by direct rotary handle as standard, by door-mounted extended rotary handle as option

  • Connections: busbars/ cables with lugs

  • Compliance with standards: EN/IEC 60947-1; IEC 60947-2; IEC 60947-4-1; UL 60947-4-1; CSA C22.2 No 60947-4-1

  • Optional Thermal Fault module (SDTAM) to indicate over-load and to open contactor (before breaker tripping) in event of over-load or phase un-balance

  • Type 1 or type 2 short-circuit co-ordination, when combined with TeSys Giga contactors.

  • TeSys Giga GV5 and GV 6 MCB Applications.


  • Various application covering industry, infrastructure, and building, including:

  • Commercial property, construction, hospitals, facilities.

  • Utilities, Oil, Gas, Energy, Water, Waste-water treatment.

  • Machinery, materials handling, mining, metals, processing plants.

  • GV5P220H TeSys GV5P Motor Protection MCB Circuit Breaker.


  • Category A to IEC 60947-2.

  • Direct rotary handle / knob / switch.

  • Isolation to EN/IEC 60947-2.

  • Breaking capacity code H 70 kA.

  • Overvoltage category III.

  • Micrologic 2.2 M Trip unit (220 A, Electronic, 3300 A trip current).

  • Overload Class 5 conforming to IEC 60947-4-1, Class 10 conforming to IEC 60947-4-1, Class 20 conforming to IEC 60947-4-1.

  • Phase failure to IEC 60947-4-1.

  • Signals LED ready / LED 95% lth.

  • Mounts horizontally and vertically by screws.

  • Weight 2.6 kg.

  • Operating temperature -25°C to 70°C.

  • Colour of MCB is RAL 7016 – Anthracite.

  • Overload protection.

  • Short-circuit protection.

  • Instantaneous short-circuit protection.

  • Phase unbalance.

  • Phase loss.

  • Breaking Capacity.


  • 70 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2.

  • 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2.

  • 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2.
  • ;Connection Terminals.;
  • Power circuit: bars - busbar cross section: 25 x 6 mm.

  • Power circuit: lugs - external diameter: 25 mm.

  • Pitch 35 mm without spreaders.
  • ;Durability.;
  • Mechanical 20,000 cycles.

  • Electrical 10,000 cycles or AC-3 at 400/415 V In.
  • ;Protection.;
  • IP40 IEC 60529.

  • IK07 IEC 62262.

  • Fire resistant to 960 °C conforming to IEC 60695-2-1.

  • Vibration resistant to IEC 60068-2-6.

  • Approvals

    IECEE CB Scheme.

    Standards

    EN/IEC 60947-1, EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1.

    相关链接