Eaton xEffect MCB, 3P, 32A Curve C, 400V AC, 10 kA Breaking Capacity
- RS庫存編號:
- 624-0399
- 製造零件編號:
- 278876 FAZ-C32/3
- 製造商:
- Eaton
Price 个**
HK$905.40
19 在3 工作日內發貨 (海外庫存)*
6 在3 工作日內發貨 (海外庫存)
* 交貨日期可能會根據您選擇的數量和交貨地址而變更。
訂單金額滿 HK$850.00 即可享受 免費 送貨服務
單位 | 每單位 |
---|---|
1 + | HK$905.40 |
** 參考價格
- RS庫存編號:
- 624-0399
- 製造零件編號:
- 278876 FAZ-C32/3
- 製造商:
- Eaton
Eaton FAZ Series MCBs
Eaton FAZ- miniature circuit breakers are Current limiting design provides fast short-circuit interruption that reduces the let-through energy that can damage the circuit, Trip-free design. Breaker cannot be defeated by holding the handle in the ON position
Features and Benefits
Thermal-magnetic overcurrent protection
Power to the circuit breakers can be fed from the line or load side
Clear indication of contact position via front switch toggle
Easy installation on DIN rail. Module width of only 17.5 mm (per pole)
Six levels of short-circuit protection, categorized by B, C, D, K, S and Z curves
Small modular width of the device and accessories saves space in the panel or equipment, which can lead to cost savings
Dual rated for IEC 60947-2 standard
Module widths: 1 Pole 17.5mm, 2 pole 35mm and 3 pole 52.5mm
Power to the circuit breakers can be fed from the line or load side
Clear indication of contact position via front switch toggle
Easy installation on DIN rail. Module width of only 17.5 mm (per pole)
Six levels of short-circuit protection, categorized by B, C, D, K, S and Z curves
Small modular width of the device and accessories saves space in the panel or equipment, which can lead to cost savings
Dual rated for IEC 60947-2 standard
Module widths: 1 Pole 17.5mm, 2 pole 35mm and 3 pole 52.5mm
Standards
IEC 60947-2 Relates to Low Voltage Circuit Breakers for use in industrial and similar
Installations. In the UK traditionally known as moulded case circuit breakers
(MCCBs) and also air circuit breakers (ACBs).
Installations. In the UK traditionally known as moulded case circuit breakers
(MCCBs) and also air circuit breakers (ACBs).
Q: What is the differences in the Tripping Curves B, C, D and S?
A: Curve B: Tripping: 3 to 5 times the rated current.
Applications: protection of generators, persons, very long cables
Curve C: Tripping: 5 to 10 times the rated current
Applications: protection of circuits and general applications
Curve D: Tripping: 10 to 14 times the rated current
Curve S Tripping 13 to 17 times the rated current
Suitable for applications where high levels of inrush current are expected. Instantaneous trip is 13–17X rating of device (In). The high magnetic trip point prevents nuisance tripping in high inductive applications such as motors, transformers and power supplies
Standards
IEC 898; BS/EN60-898; EN50 022/DIN46277-3 (BS5584).
FAZ-C*/* & FAZ-S*/* = IEC/EN60947-2
FAZ-C*/* & FAZ-S*/* = IEC/EN60947-2
FAZ-C32/3 Eaton MCB
This model has tripping type C that instantly trips at a rate of five to ten times its rated current. Breaking capacity 10kA Current rating 32 A with 3-pole, guide for secure terminal connection, 3-position DIN rail clip, permits removal from existing busbar system
• Bimetallic thermal and electromagnetic release functions protect cables and reduce system downtime
• 3-position DIN rail clip makes it easy to attach and remove from busbar systems for quick servicing and maintenance
• Easy-to-read red and green indicators under the toggles mean the circuit status is always clear
• Recessed terminals prevent fingers from accidentally touching connections to reduce the risk of shocks
• 3-position DIN rail clip makes it easy to attach and remove from busbar systems for quick servicing and maintenance
• Easy-to-read red and green indicators under the toggles mean the circuit status is always clear
• Recessed terminals prevent fingers from accidentally touching connections to reduce the risk of shocks
How much panel space do I need to mount this MCB?
This MCB has a modular design with a compact height of 80mm and width of 52.5mm to save you space on your panel.
Note
Eaton formerly known as Moeller
Standards
IEC/EN60947-2
Attribute | Value |
---|---|
Number of Poles | 3P |
Current Rating | 32A |
Tripping Characteristics | Type C |
Rated AC Voltage | 400V |
Breaking Capacity at Maximum Voltage Rating | 10 kA |
Range | xEffect |
Circuit Breaker Type | MCB |
Length | 80mm |
Width | 52.5mm |
Mounting Style | DIN Rail Mount |
Depth | 74mm |