Eaton xEffect xEffect Miniature Circuit Breaker, 3-Pole, 32A, Type C, 400V ac AC, 10 kA Breaking Capacity

小計(1 件)*

HK$814.90

Add to Basket
選擇或輸入數量
有庫存
  • 加上 20 件從 2026年4月27日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +HK$814.90

* 參考價格

RS庫存編號:
624-0399
Distrelec 貨號:
300-78-767
製造零件編號:
278876 FAZ-C32/3
製造商:
Eaton
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Eaton

Product Type

Miniature Circuit Breaker

Number of Poles

3

Current Rating

32A

Tripping Characteristics

Type C

Rated AC Voltage

400V ac

Mount Type

DIN Rail

Breaking Capacity

10kA

Range

xEffect

Series

xEffect

Terminal Type

Twin-Purpose Terminal

IP Rating

IP20

Width

74mm

Standards/Approvals

No

Depth

74mm

Reset Actuator Type

Toggle Switch

Break Time

Instantaneous

Tripping Mechanism

Thermal Magnetic

Eaton MCB, 32A Current Rating, 3 Poles - 278876 FAZ-C32/3


This MCB is a miniature circuit breaker designed for robust industrial and commercial applications. It features a compact width of 54mm and a length of 80mm, ensuring easy installation on any DIN rail setup. With a current rating of 32A and a rated AC voltage of 400V, it provides reliable protection against overcurrent situations, significantly contributing to equipment safety and longevity.

Features & Benefits


• Type C breaker ensures reliable tripping for inductive loads

• 3-pole design effectively supports three-phase systems

• Robust breaking capacity of 10 kA meets IEC standards

• Toggle switch circuit breaker offers simple manual operation

• Suitable for DIN rail mounting for easy integration

• High lifespan exceeding 10,000 operations provides durability

Applications


• Used in switchgear for industrial equipment

• Ideal for commercial electrical distribution systems

• Utilised within control panels for automation setups

• Suitable for protecting motors and transformer circuits

How does the type C characteristic enhance performance in this circuit breaker?


The type C characteristic is tailored to trip at higher fault currents, making it ideal for circuits with inductive loads like motors. This prevents nuisance tripping while offering vital protection during overload conditions.

What is the significance of a breaking capacity of 10 kA?


A breaking capacity of 10 kA indicates the ability to interrupt fault currents safely without causing damage to connected components. This ensures greater circuit integrity and reduces the risk of fire or equipment failure.

Can I mount this device in any orientation?


Yes, the mounting position can be adjusted as required, allowing flexibility in design configurations while maintaining performance reliability. This versatility aids in optimising space within electrical control systems.

Note

Eaton formerly known as Moeller

Standards

IEC/EN60947-2