Siemens, SENTRON, 3VA Molded Case Circuit Breaker 3-Pole 250A, Breaking Capacity 85 kA

小計(1 件)*

HK$12,764.30

Add to Basket
選擇或輸入數量
製造商存貨
  • 準備從 2026年12月07日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +HK$12,764.30

* 參考價格

我們的 Better World 產品系列可讓您輕鬆選擇值得信賴的環保產品。

瞭解有關RS Better World產品的更多資訊

RS庫存編號:
209-5197
製造零件編號:
3VA2225-6HL32-0AA0
製造商:
Siemens
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Siemens

Product Type

Molded Case Circuit Breaker

Range

SENTRON

Series

3VA

Number of Poles

3

Current Rating

250A

Breaking Capacity

85kA

Rated AC Voltage

690V ac

Terminal Type

Front

Standards/Approvals

CCC, CE, EAC

Width

105mm

Height

181mm

Depth

86mm

Better World Product

Yes

Better World Claim

Concentrated or Compact Solution, Extended Product Life

Tripping Characteristics

Type H

Tripping Mechanism

ETU320

COO (Country of Origin):
CZ

Siemens 3VA Series Molded Case Circuit Breaker, 250A Operational Current, 690V Rated AC Voltage - 3VA2225-6HL32-0AA0


This moulded case circuit breaker provides line protection for three-phase systems and is designed for industrial distribution. It incorporates an ETU320 electronic trip unit with long-time and instantaneous functions to manage overloads and short circuits. The device is suitable for use across a wide ambient temperature range and supports front-terminal connections for Compact panel installation.

Features and Benefits:


• 250A operational current for sustained load handling
• Type H tripping characteristic for high interrupting capacity
• Icu 85kA@415V and 3kA@690V for severe fault clearing
• Adjustable Ir 100A to 250A to match thermal protection needs
• Front Terminal with nut keeper kit for secure connections

Applications


• Suitable for industrial motor and feeder protection
• Used with distribution boards in three-phase systems
• Ideal for retrofit of line protection in switchgear
• Can be used for plant main incomer protection

What short-circuit making performance can I expect?


The making capacity reaches 242kA at 240V and 187kA at 415V, enabling strong Peak current withstand during fault inception.

How does ambient temperature affect continuous rating?


Rated at 250A up to 50°C, the permissible operational current reduces progressively above this temperature down to 213A at 70°C.

What cycle life does the device offer?


Mechanical endurance is typically 25 000 operating cycles and electrical endurance is 12 000 cycles at 380/415V, 8 400 cycles at 690V.

Which approvals cover suitability for global installations?


The unit carries CCC, CE and EAC approvals indicating compliance with those regional requirements.

What connection options exist for busbar or flat-bar terminations?


Front terminals accept flat-bar connections from 13x1mm minimum up to 25x8mm maximum with supplied nut keeper kit.