規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Schneider Electric | |
| Monitoring Application | Phase, Voltage | |
| Electrical Phase | 3 | |
| Voltage Sensing Range | 183 → 528V ac | |
| Contact Configuration | SPDT | |
| Voltage Sensitivity | Undervoltage | |
| Mounting Type | DIN Rail | |
| Phase Sensitivity | Phase Failure, Phase Sequence | |
| Time Delay | 0.1 → 10s | |
| Series | Harmony Control | |
| Better World Product | Yes | |
| Better World Verification | Green Premium | |
| Width | 17.5mm | |
| Maximum Operating Temperature | +50°C | |
| Terminal Type | Screw | |
| Minimum Voltage Sensed | 183V ac | |
| Length | 72mm | |
| Maximum Voltage Sensed | 528V ac | |
| Dimensions | 72 x 17.5 x 90mm | |
| Operating Temperature Range | -20 → +50°C | |
| Minimum Operating Temperature | -20°C | |
| Height | 90mm | |
| Special Features | IP20 Terminals | |
| Standards Met | CE, CSA, UL | |
| 選取全部 | ||
|---|---|---|
品牌 Schneider Electric | ||
Monitoring Application Phase, Voltage | ||
Electrical Phase 3 | ||
Voltage Sensing Range 183 → 528V ac | ||
Contact Configuration SPDT | ||
Voltage Sensitivity Undervoltage | ||
Mounting Type DIN Rail | ||
Phase Sensitivity Phase Failure, Phase Sequence | ||
Time Delay 0.1 → 10s | ||
Series Harmony Control | ||
Better World Product Yes | ||
Better World Verification Green Premium | ||
Width 17.5mm | ||
Maximum Operating Temperature +50°C | ||
Terminal Type Screw | ||
Minimum Voltage Sensed 183V ac | ||
Length 72mm | ||
Maximum Voltage Sensed 528V ac | ||
Dimensions 72 x 17.5 x 90mm | ||
Operating Temperature Range -20 → +50°C | ||
Minimum Operating Temperature -20°C | ||
Height 90mm | ||
Special Features IP20 Terminals | ||
Standards Met CE, CSA, UL | ||
- COO (Country of Origin):
- ID
Schneider Electric Harmony Control Series Monitoring Relay, SPDT Contact Configuration, Phase/Voltage Monitoring Application - RM17TU00
This monitoring relay is tailored for effective phase voltage supervision and electrical phase management across diverse applications. It delivers essential undervoltage protection, ensuring that systems function within specified voltage parameters. Its robust design contributes to enhanced operational efficiency and safety in electrical systems.
Features & Benefits
• Monitors voltage levels from 183 to 528VAC for broad compatibility
• Adjustable time delay from 0.1 to 10s for customised responses
• SPDT configuration provides versatility in signal management
• Compact DIN rail relay optimises installation space
• Incorporates phase failure and sequence detection for improved system reliability
• Self-extinguishing housing enhances durability in demanding environments
• Adjustable time delay from 0.1 to 10s for customised responses
• SPDT configuration provides versatility in signal management
• Compact DIN rail relay optimises installation space
• Incorporates phase failure and sequence detection for improved system reliability
• Self-extinguishing housing enhances durability in demanding environments
Applications
• Utilised for phase voltage monitoring in industrial machinery
• Employed in automation systems requiring voltage sensing
• Provides undervoltage protection in electrical cabinets
• Suitable for electrical phase monitoring in power distribution networks
• Employed in automation systems requiring voltage sensing
• Provides undervoltage protection in electrical cabinets
• Suitable for electrical phase monitoring in power distribution networks
What is the installation process for this relay?
The relay can be mounted on a standard DIN rail, requiring only screw terminal connections for quick setup.
How does the time delay function enhance operation?
The time delay feature allows for adjustable settings, preventing unnecessary tripping during transient voltage drops.
Is it suitable for varying electrical environments?
Yes, it operates effectively within a wide temperature range and is designed for both industrial and commercial applications.
Can it be integrated into existing electrical systems?
The relay is compatible with common electrical setups and can be incorporated without extensive modifications.
What maintenance is required for optimal performance?
Regular inspections are advised to ensure terminals are secure and clean, although the device is designed for minimal upkeep.
Schneider Electric Voltage, Current, Phase & Motor Protection
相关链接
- Crouzet Phase 3 Phase 183 → 528V ac, DIN Rail
- Crouzet Voltage Monitoring Relay SPDT DIN Rail
- Schneider Electric Phase 3 Phase 183 → 528V ac, DIN Rail
- Schneider Electric Voltage Monitoring Relay SPDT DIN Rail
- Schneider Electric Phase Monitoring Relay SPDT DIN Rail
- Crouzet Voltage Monitoring Relay DPDT DIN Rail
- Schneider Electric Phase Monitoring Relay SPDT DIN Rail
- Schneider Electric Voltage Monitoring Relay DPDT DIN Rail