Dold Level Monitoring Relay, DIN Rail
- RS庫存編號:
- 327-7663
- 製造零件編號:
- IL9151.12 2- 50kOHM DC24V 0.2-20S
- 製造商:
- Dold
小計(1 件)*
HK$1,846.55
訂單超過 HK$250.00 免費送貨
暫時缺貨
- 從 2026年1月19日 發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | HK$1,846.55 |
* 參考價格
- RS庫存編號:
- 327-7663
- 製造零件編號:
- IL9151.12 2- 50kOHM DC24V 0.2-20S
- 製造商:
- Dold
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Dold | |
| Monitoring Application | Level | |
| Mounting Type | DIN Rail | |
| Time Delay | 0.2 → 20s | |
| Series | IL 9151 | |
| Dimensions | 59 x 35 x 90mm | |
| Maximum Operating Temperature | +60°C | |
| Width | 35mm | |
| Minimum Operating Temperature | -20°C | |
| Operating Temperature Range | +60°C | |
| Length | 59mm | |
| Height | 90mm | |
| 選取全部 | ||
|---|---|---|
品牌 Dold | ||
Monitoring Application Level | ||
Mounting Type DIN Rail | ||
Time Delay 0.2 → 20s | ||
Series IL 9151 | ||
Dimensions 59 x 35 x 90mm | ||
Maximum Operating Temperature +60°C | ||
Width 35mm | ||
Minimum Operating Temperature -20°C | ||
Operating Temperature Range +60°C | ||
Length 59mm | ||
Height 90mm | ||
- COO (Country of Origin):
- DE
IL9151 - level relay with two separately operating changeovers
The IL9151 is used for
Level monitoring and control of conductive liquids and powders, e.g. maximum and minimum fill level, protection against overfilling and dry running
Monitoring and control of the mix ratio for conductive liquids
General resistance monitoring tasks, e.g. recording temperature limits with PTC
Contact protection relay with delay
Monitoring and control of the mix ratio for conductive liquids
General resistance monitoring tasks, e.g. recording temperature limits with PTC
Contact protection relay with delay
Features
In accordance with IEC 255, VDE 0435 Section 303
3 electrode connections for 2-point or 1-point level control
The measuring circuit galvanically isolated from the mains is immune from high levels of interference
Max. lead length to the electrodes: 1500 m
Wide setting range of 4 → 450 kΩ, which enables differentiation between liquid and foam
Response and fallback delay: 0.2 → 20 s adjustable separately for MIN and MAX level
Programmable for: 2 separately controlled output relays for MIN and MAX level or jointly controlled output relays in 2-point hysteresis level control
Programmable for: Operating or rest current principle
Measuring circuit for electrodes works on AC voltage generated internally in the device (approx. 30 Hz); therefore no electrolysis occurrence in the fluid
LEDs to indicate operational readiness and contact position
2 output relays each with 1 changeover
35 mm overall width
3 electrode connections for 2-point or 1-point level control
The measuring circuit galvanically isolated from the mains is immune from high levels of interference
Max. lead length to the electrodes: 1500 m
Wide setting range of 4 → 450 kΩ, which enables differentiation between liquid and foam
Response and fallback delay: 0.2 → 20 s adjustable separately for MIN and MAX level
Programmable for: 2 separately controlled output relays for MIN and MAX level or jointly controlled output relays in 2-point hysteresis level control
Programmable for: Operating or rest current principle
Measuring circuit for electrodes works on AC voltage generated internally in the device (approx. 30 Hz); therefore no electrolysis occurrence in the fluid
LEDs to indicate operational readiness and contact position
2 output relays each with 1 changeover
35 mm overall width
Liquid Level Relays are used to monitor the levels of conductive liquids, and are available in Up/Down, Minimum, Maximum, and Fill/Empty variations. Liquid Level Relays are straightforward to install and safe to use.
Application Examples
Liquid Level Relays (Conductive Level Sensors) are used in a wide variety of applications including waste water management and the monitoring and management of corrosive liquid media, and designed specifically to provide for the:
Monitoring and control of liquid levels
Protection of pumps against dry running
Ability to detect liquid leaks in a system
Control of media mixing ratios
Control of liquid levels
Protection of pumps against dry running
Ability to detect liquid leaks in a system
Control of media mixing ratios
Control of liquid levels
相关链接
- Dold Level Monitoring Relay, DIN Rail
- Dold Liquid Level Relay - DIN Rail, 24 V dc 1
- Dold Frequency Monitoring Relay DIN Rail
- Dold Monitoring Relay DIN Rail
- Dold Temperature Monitoring Relay DIN Rail
- Dold Thermistor Motor Protection Monitoring Relay DIN Rail
- Dold Temperature Monitoring Relay DIN Rail
- Dold Current Monitoring Relay DIN Rail