Siemens Current Monitoring Relay, 1 Phase, DPDT, DIN Rail
- RS庫存編號:
- 758-6955
- 製造零件編號:
- 3UG4641-1CS20
- 製造商:
- Siemens
小計(1 件)*
HK$2,881.50
訂單超過 HK$250.00 免費送貨
最後的 RS 庫存
- 最終 1 個,準備發貨
單位 | 每單位 |
|---|---|
| 1 + | HK$2,881.50 |
* 參考價格
- RS庫存編號:
- 758-6955
- 製造零件編號:
- 3UG4641-1CS20
- 製造商:
- Siemens
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Siemens | |
| Monitoring Application | Current | |
| Electrical Phase | 1 | |
| Contact Configuration | DPDT | |
| Mounting Type | DIN Rail | |
| Minimum Current Sensed | 0.2A | |
| Maximum Current Sensed | 10A | |
| Current Sensitivity | No Current, Overcurrent, Undercurrent | |
| Time Delay | 0.1 → 20s | |
| Series | 3UG4 | |
| Minimum Operating Temperature | -25°C | |
| Width | 22.5mm | |
| Dimensions | 91 x 22.5 x 102mm | |
| Maximum Operating Temperature | +60°C | |
| Height | 102mm | |
| Length | 91mm | |
| Terminal Type | Screw | |
| Number of Poles | 2 | |
| Operating Temperature Range | +60°C | |
| 選取全部 | ||
|---|---|---|
品牌 Siemens | ||
Monitoring Application Current | ||
Electrical Phase 1 | ||
Contact Configuration DPDT | ||
Mounting Type DIN Rail | ||
Minimum Current Sensed 0.2A | ||
Maximum Current Sensed 10A | ||
Current Sensitivity No Current, Overcurrent, Undercurrent | ||
Time Delay 0.1 → 20s | ||
Series 3UG4 | ||
Minimum Operating Temperature -25°C | ||
Width 22.5mm | ||
Dimensions 91 x 22.5 x 102mm | ||
Maximum Operating Temperature +60°C | ||
Height 102mm | ||
Length 91mm | ||
Terminal Type Screw | ||
Number of Poles 2 | ||
Operating Temperature Range +60°C | ||
- COO (Country of Origin):
- DE
Single Phase Current Monitoring Relay
Current monitoring relays to monitor single phase AC currents and DC currents against the set threshold value for undershoot and overshoot.
A current monitoring relay can differ with their measuring ranges and supply voltage types.
Features and Benefits
Real effective value measurement
Applicable for frequencies with 40-500Hz AC and DC
All devices can be digitally set and have an LCD display, a fault memory can be switched on
Simultaneous monitoring of overcurrent and undercurrent over the complete measuring range
Supply voltage 24-240Vac/dc
Starting by-pass time 0.1 -20 secs.
Off delay 0.1 - 20 secs.
Contacts 1 C/O
Applicable for frequencies with 40-500Hz AC and DC
All devices can be digitally set and have an LCD display, a fault memory can be switched on
Simultaneous monitoring of overcurrent and undercurrent over the complete measuring range
Supply voltage 24-240Vac/dc
Starting by-pass time 0.1 -20 secs.
Off delay 0.1 - 20 secs.
Contacts 1 C/O
Product Application Information
Overcurrent and undercurrent monitoring
Monitoring the functionality of electrical loads
Open-circuit monitoring
Threshold switch for analog signals from 4 mA to 20 mA
相关链接
- Crouzet Current Monitoring Relay DPDT, DIN Rail
- Siemens Current Monitoring Relay DPDT, DIN Rail
- Hiquel Current Monitoring Relay DPDT, DIN Rail
- Tele Current Monitoring Relay DPDT, DIN Rail
- Phoenix Contact Current Monitoring Relay DPDT, DIN Rail
- Schneider Electric Current Monitoring Relay DPDT, DIN Rail
- Schneider Electric Current Monitoring Relay DPDT, DIN Rail
- ABB Current Monitoring Relay DPDT, DIN Rail