Fluke Fluke 190 series III ScopeMeter Series, 500 MHz Portable Oscilloscope, 4 Channels

小計(1 件)*

HK$132,557.10

Add to Basket
選擇或輸入數量
暫時缺貨
  • 2 件從 2026年10月15日 起裝運發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +HK$132,557.10

* 參考價格

RS庫存編號:
271-0127
Distrelec 貨號:
303-89-920
製造零件編號:
FLUKE-MDA-550/FPC EU
製造商:
Fluke
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Fluke

Product Type

Oscilloscope

Bandwidth

500MHz

Number of Channels

4

Oscilloscope Type

Portable

Oscilloscope Form

Digital Storage

Interface Type

USB

Memory Depth

400Mpts

Series

Fluke 190 series III ScopeMeter

Standards/Approvals

IEC 61010-2-030, IEC 61010-3

Battery Life

7h

Display Type

Colour

Battery Type

Lithium-ion

Safety Category Level

CAT III, CAT IV

Safety Category Voltage

600V, 1V

Power Source

Battery

COO (Country of Origin):
RO

Fluke 190 series III ScopeMeter Series Oscilloscope, 500MHz Bandwidth, 4 Channels - FLUKE-MDA-550/FPC EU


This oscilloscope is a portable motor-drive diagnostic instrument designed for field use on inverter-type systems, combining oscilloscope, waveform analyser and data logger capabilities to support voltage, current and harmonics analysis across drive input, DC bus, drive output and motor.

Features and Benefits:


• 500MHz bandwidth enables high-frequency voltage modulation analysis
• 4-channel input allows simultaneous multi-point measurements
• 400Mpts memory depth captures extended waveform records
• Lithium-ion battery provides 7h battery life for prolonged field work
• USB Interface and Wi-Fi support facilitate data transfer to PC
• 1000V maximum and CAT III/CAT IV safety ratings protect operators

Applications


• Suitable for diagnosing inverter output voltage modulation issues
• Used for measuring DC bus voltage level and ripple
• Ideal for detecting motor shaft voltage discharge events
• Can be used to assess harmonics up to 150kHz and beyond
• Used with current clamps for unbalance and load current checks

What probe options support high-voltage measurements?


The instrument accepts a range of voltage probe ratios including 1:1, 10:1, 100:1 and higher to permit measurements up to 1000V with compatible probes.

How are reports generated and exported in the field?


The unit can save multiple screens into a text-based report on an attached USB stick and transfer data via mini-USB or Wi-Fi for PC analysis.

What harmonic and spectrum ranges can it measure?


Harmonic analysis covers DC to the 51st harmonic with spectrum bands from 1-9kHz, 9-150kHz and extended voltage modulation sensing up to the device bandwidth.

Which inputs accept direct connection and what are their limits?


BNC inputs A-D accept direct connections rated to 300V CAT IV while probe-assisted measurements allow up to 1000V between terminals and earth.

How does it detect motor shaft discharge events?


A dedicated shaft voltage probe and supplied carbon-fibre brush tips Record impulse amplitude, event counts and timing to reveal flashover activity.