ABB Residual Current Circuit Breaker with Overload Protection, 32A Current Rating, 2-Pole, 300 mA Trip Sensitivity, Type

小計(1 件)*

HK$994.20

Add to Basket
選擇或輸入數量
有庫存
  • 15 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +HK$994.20

* 參考價格

RS庫存編號:
201-6975
製造零件編號:
2CSR255080R3324 DS201 C32 AC300
製造商:
ABB
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

ABB

Current Rating

32A

Product Type

Residual Current Circuit Breaker with Overload Protection

Number of Poles

2

Range

System Pro M Compact

Series

DS201

Trip Sensitivity

300mA

Tripping Characteristics

Type C

Mount Type

DIN Rail

Rated AC Voltage

240V ac

Terminal Type

Screw

Earth Leakage Protection Type

AC

Width

35mm

Depth

69mm

Height

85mm

Tripping Mechanism

Thermal Magnetic

Standards/Approvals

IEC, RoHS

Reset Actuator Type

Toggle Switch

Breaking Capacity

10kA

ABB DS201 Series RCBO, 32A Current Rating, 300mA Trip Sensitivity - 2CSR255080R3324 DS201 C32 AC300


This RCBO is designed for the protection of single-phase electrical circuits. With a current rating of 32A and a trip sensitivity of 300 mA, it ensures safety against overload, short circuits, and earth faults. The device complies with relevant IEC and EN standards, providing reliability in its operation. It features a compact design with dimensions measuring 69mm in length, 35mm in width, and 69mm in depth, allowing easy installation on DIN rails.

Features & Benefits


• Provides short circuit protection to safeguard electrical systems

• Instantaneous breaking capacity of 10 kA enhances safety

• Type C tripping characteristics prevent nuisance tripping

• Two-pole configuration effectively protects circuits from faults

• Screw terminals allow secure cable connections

• Toggle switch reset actuator simplifies operation

Applications


• Used for protecting home and commercial single-phase electrical circuits

• Effective in preventing electric shocks from earth fault currents

• Utilised in automated systems requiring reliable overcurrent protection

• Ideal for installations needing compact and efficient circuit breakers

What is the benefit of the 300 mA sensitivity rating?


A sensitivity of 300 mA provides added protection against earth faults, reducing the risk of electric shocks while allowing standard operational currents to pass safely.

What installation considerations are required for the two-pole design?


The two-pole configuration allows for connection to both the phase and neutral conductors, ensuring comprehensive circuit protection and compliance with electrical regulations.

How does the toggle switch contribute to the device's usability?


The toggle switch allows for quick manual resetting after a trip, offering ease of use in ensuring the system can be promptly restored to operational status.