ABB FH200 Series Residual Current Circuit Breaker, 63A, 2-Pole, 30 mA, Type AC, 0.03 A 400V ac
- RS庫存編號:
- 540-1638
- 製造零件編號:
- 2CSF202006R1630 FH202 AC-63/0,03
- 製造商:
- ABB
可享批量折扣
小計(1 件)*
HK$739.18
库存信息目前无法访问 - 请稍候查看
單位 | 每單位 |
|---|---|
| 1 - 11 | HK$739.18 |
| 12 + | HK$708.14 |
* 參考價格
- RS庫存編號:
- 540-1638
- 製造零件編號:
- 2CSF202006R1630 FH202 AC-63/0,03
- 製造商:
- ABB
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | ABB | |
| Product Type | Residual Current Circuit Breaker | |
| Current Rating | 63A | |
| Number of Poles | 2 | |
| Range | RCCBs F200 | |
| Series | FH200 | |
| Trip Sensitivity | 30mA | |
| Mount Type | DIN Rail | |
| Tripping Characteristics | Type AC | |
| Terminal Type | Screw | |
| Standards/Approvals | RoHS, CE | |
| Width | 35mm | |
| Height | 85mm | |
| Depth | 85mm | |
| Breaking Capacity | 0.03A | |
| Reset Actuator Type | Toggle Switch | |
| Break Time | Instantaneous | |
| Earth Leakage Protection Type | AC | |
| Rated AC Voltage | 400V ac | |
| 選取全部 | ||
|---|---|---|
品牌 ABB | ||
Product Type Residual Current Circuit Breaker | ||
Current Rating 63A | ||
Number of Poles 2 | ||
Range RCCBs F200 | ||
Series FH200 | ||
Trip Sensitivity 30mA | ||
Mount Type DIN Rail | ||
Tripping Characteristics Type AC | ||
Terminal Type Screw | ||
Standards/Approvals RoHS, CE | ||
Width 35mm | ||
Height 85mm | ||
Depth 85mm | ||
Breaking Capacity 0.03A | ||
Reset Actuator Type Toggle Switch | ||
Break Time Instantaneous | ||
Earth Leakage Protection Type AC | ||
Rated AC Voltage 400V ac | ||
豁免
2 & 4 Pole RCCB - FH200 Series
Compact AC DIN rail mount 2 and 4 Pole RCCBs
Protects against the effects of sinusoidal alternating earth fault currents
Protects against indirect contact with additional protection against direct (with IΔn=30 mA) contact
Command and isolation of resistive and inductive circuits
Suitable for residential and commercial applications
ABB RCBO's & RCCB's
RCBO's : DIN rail mounting with an operating temperature range of -25 to +55 °C. Optimum frequency range of 50 to 60Hz
Note
RCCBs are sensitive only to earth fault current (therefore they have to be connected in series with a MCB or a fuse to protect them against over-current and short-circuits).
Standards
IEC/EN 61008
相关链接
- ABB FH200 Series Residual Current Circuit Breaker 4-Pole Type AC, 0.03 A 400V ac
- ABB FH200 Series Residual Current Circuit Breaker 2-Pole Type AC, 0.03 A 400V ac
- ABB FH200 Series Residual Current Circuit Breaker 2-Pole Type AC, 0.03 A 230V ac
- ABB FH200 Series Residual Current Circuit Breaker 4-Pole Type AC, 0.03 A 400V ac
- ABB FH200 Series Residual Current Circuit Breaker 4-Pole Type AC, 0.03 A 400V ac
- ABB F200 Series Residual Current Circuit Breaker 4-Pole Type AC, 0.03 A 400V ac
- ABB F200 Series Residual Current Circuit Breaker 2-Pole Type AC, 0.03 A 400V ac
- ABB FH200 Series Residual Current Circuit Breaker 2-Pole Type AC, 1 kA 230V ac