Eaton PKNM Series Residual Current Device, 10A, 2-Pole, 30 mA, Type C, 10 kA 230V ac
- RS庫存編號:
- 922-8715
- Distrelec 貨號:
- 300-42-688
- 製造零件編號:
- 236082 PKNM-10/1N/C/003-A-MW
- 製造商:
- Eaton
小計(1 件)*
HK$1,113.60
訂單超過 HK$250.00 免費送貨
有庫存
- 190 件準備從其他地點送貨
- 加上 29 件從 2026年6月02日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | HK$1,113.60 |
* 參考價格
- RS庫存編號:
- 922-8715
- Distrelec 貨號:
- 300-42-688
- 製造零件編號:
- 236082 PKNM-10/1N/C/003-A-MW
- 製造商:
- Eaton
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Eaton | |
| Product Type | Residual Current Device | |
| Current Rating | 10A | |
| Number of Poles | 2 | |
| Series | PKNM | |
| Range | PKNM | |
| Trip Sensitivity | 30mA | |
| Mount Type | DIN Rail | |
| Tripping Characteristics | Type C | |
| Terminal Type | Screw | |
| Standards/Approvals | CE | |
| Height | 80mm | |
| Depth | 70.5mm | |
| Width | 70mm | |
| Breaking Capacity | 10kA | |
| Application | Industrial | |
| Rated AC Voltage | 230V ac | |
| Earth Leakage Protection Type | Type A | |
| Break Time | Instantaneous | |
| Tripping Mechanism | Electromagnetic | |
| Reset Actuator Type | Toggle Switch | |
| 選取全部 | ||
|---|---|---|
品牌 Eaton | ||
Product Type Residual Current Device | ||
Current Rating 10A | ||
Number of Poles 2 | ||
Series PKNM | ||
Range PKNM | ||
Trip Sensitivity 30mA | ||
Mount Type DIN Rail | ||
Tripping Characteristics Type C | ||
Terminal Type Screw | ||
Standards/Approvals CE | ||
Height 80mm | ||
Depth 70.5mm | ||
Width 70mm | ||
Breaking Capacity 10kA | ||
Application Industrial | ||
Rated AC Voltage 230V ac | ||
Earth Leakage Protection Type Type A | ||
Break Time Instantaneous | ||
Tripping Mechanism Electromagnetic | ||
Reset Actuator Type Toggle Switch | ||
- COO (Country of Origin):
- RO
Eaton RCD, Screw Terminals, Front Toggle Switch - PKNM Series - 236082 PKNM-10/1N/C/003-A-MW
Keep your people safe from electric shocks with this RCD from Eaton. Its type-C tripping characteristics make it suitable for protecting more powerful motors. If the current exceeds two to five times the rated load, the unit will trip and shut off the power before any damage can be done. Once you've found and rectified the fault, simply flick the toggle switch to reset the RCD and get up and running again.
Features & Benefits
• Screw terminals help you quickly make secure electrical connections
• Red and green contact position indicators let you check the status at a glance
• Single-pole plus neutral configuration means it protects both the phase and neutral conductors in single-phase loads such as lighting
• 10A current rating to protect circuits with the same input
What's the difference between an RCD and an MCB?
An RCD (residual current device) is a safety device that detects and disconnects power when it senses a leakage of current. An MCB (miniature circuit breaker) is designed to protect circuits from overcurrents and short circuits by interrupting the flow of current. While both enhance electrical safety, an RCD focuses on keeping people safe rather than protecting the circuit.
Note
Eaton formerly known as Moeller
相关链接
- Eaton PKNM Series Residual Current Device 2-Pole Type C, 10 kA 230V ac
- Eaton PKNM Series Residual Current Device 2-Pole Type B, 10 kA 230V ac
- Eaton PKNM Series Residual Current Device 2-Pole Type C, 10 kA 230V ac
- Eaton PKNM Series Residual Current Device 2-Pole Type C, 10 kA 230V ac
- Eaton PKNM Series Residual Current Device 2-Pole Type C, 10 kA 230V ac
- Eaton PKNM Series Residual Current Device 2-Pole Type C, 10 kA 230V ac
- Eaton PKNM Series Residual Current Device 2-Pole Type C, 10 kA 230V ac
- Eaton PKNM Series Residual Current Device 2-Pole Type C, 10 kA 230V ac
