Eaton RCD, 10A, 2 Pole, 30mA, Type C, 230V
- RS庫存編號:
- 922-8715
- 製造零件編號:
- 236082 PKNM-10/1N/C/003-A-MW
- 製造商:
- Eaton
Price 个**
HK$1,081.20
48 現貨庫存,可於4工作日發貨。*
* 交貨日期可能會根據您選擇的數量和交貨地址而變更。
訂單金額滿 HK$850.00 即可享受 免費 送貨服務
單位 | 每單位 |
---|---|
1 + | HK$1,081.20 |
** 參考價格
- RS庫存編號:
- 922-8715
- 製造零件編號:
- 236082 PKNM-10/1N/C/003-A-MW
- 製造商:
- Eaton
- COO (Country of Origin):
- RO
Eaton RCD, Screw Terminals, Front Toggle Switch - PKNM Series - 236082 PKNM-10/1N/C/003-A-MW
Keep your people safe from electric shocks with this RCD from Eaton. Its type-C tripping characteristics make it suitable for protecting more powerful motors. If the current exceeds two to five times the rated load, the unit will trip and shut off the power before any damage can be done. Once you've found and rectified the fault, simply flick the toggle switch to reset the RCD and get up and running again.
Features & Benefits
• Screw terminals help you quickly make secure electrical connections
• Red and green contact position indicators let you check the status at a glance
• Single-pole plus neutral configuration means it protects both the phase and neutral conductors in single-phase loads such as lighting
• 10A current rating to protect circuits with the same input
• Red and green contact position indicators let you check the status at a glance
• Single-pole plus neutral configuration means it protects both the phase and neutral conductors in single-phase loads such as lighting
• 10A current rating to protect circuits with the same input
What's the difference between an RCD and an MCB?
An RCD (residual current device) is a safety device that detects and disconnects power when it senses a leakage of current. An MCB (miniature circuit breaker) is designed to protect circuits from overcurrents and short circuits by interrupting the flow of current. While both enhance electrical safety, an RCD focuses on keeping people safe rather than protecting the circuit.
Note
Eaton formerly known as Moeller
Attribute | Value |
---|---|
Circuit Breaker Type | RCD |
Current Rating | 10A |
Number of Poles | 2 |
Range | PKNM |
Trip Sensitivity | 30mA |
Tripping Characteristics | Type C |
Voltage Rating | 230V |
Standards Met | CE |
Rated AC Voltage | 230V |
Mounting Style | DIN Rail Mount |
Breaking Capacity at Maximum Voltage Rating | 10 kA |
Break Time | Instantaneous |
Reset Actuator Type | Toggle Switch |
Overall Dimensions | 35 x 65.5 x 80mm |
Earth Leakage Protection Type | A |
Overall Length | 35mm |
Terminal Contact Type | Screw |
Overall Width | 65.5mm |
Overall Depth | 80mm |