Schneider Electric | Preventa XPSAK Series | Safety Relays
Simple and effective safety monitoring has never been more crucial in today's highly automated world. Prevention is key to site safety, that's why Schneider Electric offers a Safety Relay in the form of the 'Preventa XPSAK' module that is second to none. Being able to monitor faults with devices along a circuit has the power to stop emergency situations from even occurring.
Features and benefits:
Provides 3 N/O safety relay outputs plus 1 N/C volt free signalling output
Monitoring of the start button or automatic starting can be chosen.
24 V DC option incorporated for each supply voltage version
Monitoring of single safety functions, providing an automated solution for use with applications such as emergency push stop buttons or switches.
Slin in design, with just 45mm of width meaning it can fit nicely even in space constraint spaces.
35 mm symmetrical DIN rail support, offering flexible and versatile safety system installation.
Local signalling in the form of LEDs.
Protection ratings & Safety features (see datasheet for specifics) -
Impressive line resistance is available, varying between 90 to 100 Ohm (Ω).
Input protection type is internal, electronic.
EN1088/ISO 14119, EN 60204-1, EN/IEC 60947-5-1, EN/ISO 13850
CSA, TUV & UL listed
IP 40 (enclosure) for protection against small objects up to 1mm such as tools, wires and small wires.
IP 20 (terminals) for protection against solid objects such as fingers, smaller tools up to 12mm.
Monitoring of the start button or automatic starting can be chosen.
24 V DC option incorporated for each supply voltage version
Monitoring of single safety functions, providing an automated solution for use with applications such as emergency push stop buttons or switches.
Slin in design, with just 45mm of width meaning it can fit nicely even in space constraint spaces.
35 mm symmetrical DIN rail support, offering flexible and versatile safety system installation.
Local signalling in the form of LEDs.
Protection ratings & Safety features (see datasheet for specifics) -
Impressive line resistance is available, varying between 90 to 100 Ohm (Ω).
Input protection type is internal, electronic.
EN1088/ISO 14119, EN 60204-1, EN/IEC 60947-5-1, EN/ISO 13850
CSA, TUV & UL listed
IP 40 (enclosure) for protection against small objects up to 1mm such as tools, wires and small wires.
IP 20 (terminals) for protection against solid objects such as fingers, smaller tools up to 12mm.
Applications -
All dangerous machinery requires an automated solution to prevent harm to immediate users and also prevent damage to the machinery. Below are some of the safety applications
Monitoring type 4 Safety light curtains with semi-conductor outputs according to EN61496-1.
Time delay input if needed allowing you to set up your own time function.
Two-hand control safety circuits
Sensing mats and edges
Monitoring type 4 Safety light curtains with semi-conductor outputs according to EN61496-1.
Time delay input if needed allowing you to set up your own time function.
Two-hand control safety circuits
Sensing mats and edges
Standards
IEC 204-1; EN 292; EN 418; EN 60204-1; EN 1088
Approvals
BG, UL, CSA
XPSAK361144 Schneider Electric Preventa Safety Relay Module.
- Preventa safety module XPSAK.
- For emergency stop, switch, sensing mat (edges), safety light curtain monitoring.
- Functions - Monitoring of electro-sensitive protection equipment (ESPE), Monitoring of a movable guard associated with 2 switches and automatic start, Monitoring of a movable guard, Multiple emergency stop monitoring 2-channel wiring, Emergency stop with 2 NC contacts monitoring 2-channel wiring, Sensing mat and edges monitoring, Proximity sensor monitoring, Emergency stop monitoring 1-channel wiring.
- Captive screw clamp terminals.
- 3 NO (volt free).
- 1 NC + 4 - Solid state output additional circuit.
- Frequency 50/60 Hz.
- Supply voltage 24 V dc.
- Time between inputs Unlimited (manual start), 2 or 4 s depending of wiring (automatic start).
- Maximum power consumption 6 VA AC.
- Breaking 180 VA holding AC-15 C300 relay output, 1800 VA inrush AC-15 C300 relay output, 1.5 A at 24 V (DC-13) time constant: 50 ms for relay output.
- Minimum output current 10 MA (relay output).
- Minimum output voltage 17 V (relay output).
- Response time 40 Ms (input open).
- 4 LEDs.
- Mounting 35 mm DIN rail.
- Net weight 0.4 Kg.
XPSAK361144 Standards.
- EN/ISO 13850, EN 1088/ISO 14119, EN/IEC 60947-5-1, EN/IEC 60204-1.
Certification.
- CSA, UL, TUV.
規格
Attribute | Value |
---|---|
Supply Voltage | 110V ac |
Number of Channels | 2 |
Safety Contacts | 3 |
Function | Light Beam/Curtain, Safety Mat/Edge, Safety Switch/Interlock |
Auxiliary Contacts | 1 |
Reset Method | Automatic & Manual |
Range | Preventa |
Safety Category ISO 13849-1 | 4 |
PL ISO 13849-1 | e |
SIL IEC 61508 | 3 |
Terminal Type | Screw |
Configurable | Yes |
Series | XPS AK |
Width | 45mm |
Better World Verification | Green Premium |
Depth | 114mm |
Better World Product | Yes |
Performance Level | e |
Length | 99mm |