Schneider Electric TeSys GB2 Thermal Circuit Breaker -, 1A Current Rating 1-Pole, DIN Rail

小計(1 件)*

HK$402.00

Add to Basket
選擇或輸入數量
有庫存
  • 27 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +HK$402.00

* 參考價格

RS庫存編號:
323-8999
製造零件編號:
GB2CD06
製造商:
Schneider Electric
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Schneider Electric

Current Rating

1A

Product Type

Thermal Circuit Breaker

Series

GB2

Range

TeSys

Number of Poles

1

Width

15mm

Mount Type

DIN Rail

Terminal Type

Cable

Tripping Mechanism

Thermal Magnetic

Reset Actuator Type

Toggle Switch

Depth

67mm

Height

74mm

Rated AC Voltage

110V ac

Standards/Approvals

RoHS, CE

Breaking Capacity

10kA

Break Time

Medium

Rated DC Voltage

48V dc

Schneider Electric GB2 Series Thermal Circuit Breaker, 1A Current, 10kA Breaking Capacity - GB2CD06


This thermal circuit-breaker provides Compact overcurrent protection for control and distribution panels in industrial electrical networks. It combines thermal and magnetic tripping to protect circuits against overloads and short circuits while being suited to DIN-rail mounting in automation and electrical installations.

Features & Benefits


• 1A rated current offering precise protection for low-current circuits
• 10 kA breaking capacity enabling secure interruption of fault currents
• Thermal-magnetic trip unit for overload and short-circuit discrimination
• Toggle reset actuator for Rapid manual reclosure after fault clearance
• IP20 protection ensuring Basic finger-safe access in panel environments
• 4 kV impulse withstand voltage tolerating transient overvoltages

Applications


• Suitable for control panel circuits in industrial automation systems
• Ideal for protecting control transformers and small loads
• Used with PLC input power feeds requiring Compact protection
• Can be used for branch circuits in machinery control cabinets
• Suitable for retrofit on existing DIN-rail assemblies

What Terminal connections are supported for field wiring?


It accepts solid conductors up to 6mm² and flexible conductors with ferrules to 4mm² on one side and to 2.5mm² on the other, tightened to 1.2 N·m.

How does mechanical and electrical durability affect maintenance schedules?


Both mechanical and electrical lifetimes are specified at 8,000 cycles, allowing predictable replacement intervals based on operational switching frequency.

What environmental limits govern installation locations?


It operates between −20 to 60 °C, stores between −40 to 80 °C, and is rated for use up to 3,000 m altitude.

How is the device mounted and positioned within enclosures?


It clips to standard DIN rail or plate supports and may be installed horisontally or vertically.

What regulatory approvals does the unit hold for industrial use?


It carries recognised certifications to EN/IEC standards Plus UL and CSA listings for use in compliant electrical equipment.

Standards

IEC947-2