Nuvotem Talema 230 V ac 2 x 50 V ac Toroidal Transformer 2 Output 500 VA, UL, VDE
- RS庫存編號:
- 223-8308
- 製造零件編號:
- 0500P1-2-050
- 製造商:
- Nuvotem Talema
此圖片僅供參考,請參閲產品詳細資訊及規格
可享批量折扣
小計(1 件)*
HK$1,284.30
訂單超過 HK$250.00 免費送貨
有庫存
- 179 件準備從其他地點送貨
- 加上 216 件從 2026年3月09日 起發貨
- 加上 120 件從 2026年4月20日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 - 9 | HK$1,284.30 |
| 10 - 24 | HK$1,239.40 |
| 25 - 49 | HK$1,215.30 |
| 50 - 99 | HK$1,190.20 |
| 100 + | HK$1,164.20 |
* 參考價格
- RS庫存編號:
- 223-8308
- 製造零件編號:
- 0500P1-2-050
- 製造商:
- Nuvotem Talema
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Nuvotem Talema | |
| Primary Voltage | 230 V ac | |
| Product Type | Toroidal Transformer | |
| Secondary Voltage | 2 x 50 V ac | |
| Number of Outputs | 2 | |
| Secondary Current | 5 A | |
| Power | 500VA | |
| Weight | 3.5kg | |
| Diameter | 136 mm | |
| Minimum Operating Temperature | 0°C | |
| Winding Type | Dual Secondary | |
| Maximum Operating Frequency | 450Hz | |
| Toroid Centre | Potted | |
| Maximum Operating Temperature | 120°C | |
| Termination Type | Copper Conductor Termination Wire | |
| Height | 60mm | |
| Standards/Approvals | UL, VDE | |
| 選取全部 | ||
|---|---|---|
品牌 Nuvotem Talema | ||
Primary Voltage 230 V ac | ||
Product Type Toroidal Transformer | ||
Secondary Voltage 2 x 50 V ac | ||
Number of Outputs 2 | ||
Secondary Current 5 A | ||
Power 500VA | ||
Weight 3.5kg | ||
Diameter 136 mm | ||
Minimum Operating Temperature 0°C | ||
Winding Type Dual Secondary | ||
Maximum Operating Frequency 450Hz | ||
Toroid Centre Potted | ||
Maximum Operating Temperature 120°C | ||
Termination Type Copper Conductor Termination Wire | ||
Height 60mm | ||
Standards/Approvals UL, VDE | ||


Open Style with Leads, 15VA to 1000VA
High-quality open style toroidal transformers with a single 230 Vac 50/60 Hz primary winding. Twin secondary windings may be connected in series or parallel or used independently.
Small size and low weight compared with traditional stacked lamination types
Extremely low level of radiated magnetic field and very low induced noise (hum)
Very low iron losses
Double insulated primary leads
100% electrical and flash tested
High-quality manufacturing and testing in accordance to EN61558, EN60950, EN60065, VDE 0551, VDE 0550 and BS415
Approvals
UL 506; EN 61558
Warning
Under no circumstances should both ends of the fixing bolt simultaneously contact the metal chassis or framework as this would create a potentially dangerous 'shorted-turn'.
Standards
UL 506; EN 61558
Supplied with
Full mounting kit