Oscilloscope Probes | Scope Probes | RS
最近搜索

    Oscilloscope Probes

    Oscilloscope probes are a type of device commonly used by electrical engineers that can connect a signal source to an oscilloscope. The probe is a single input device that can divert the electrical signal to the scope. Oscilloscope probes can be used in various applications and can range from a simple wire like a passive probe to a more complex device.

    An oscilloscope is considered to be the most used instrument for electrical engineers who need to measure electrical characteristics of electronic devices but you also need at least one probe.

    Things to consider when choosing probes

    • Ensure the probe's input connector matches the connector on your scope
    • Choose a probe whose input resistance and capacitance match the input resistance and capacitance of your scope - matching is critical for guaranteeing proper signal transfer and signal accuracy

    The best approach, for matching a probe with a scope, is to first choose a probe whose capacitance is within the range of your scope and then fine-tune the probe's capacitance by adjusting its compensation network using the probe's trimmer capacitor.

    The 1X probes are suitable for many low frequency applications. They typically offer the same input impedance of the oscilloscope which is normally 1 M Ohm. The most common type of probe with a built in attenuator gives an attenuation of ten, and it is known as a 10X oscilloscope probe.

    Types of probes

    Passive probes are the most commonly used probes for taking measurements. They are easy to use, relatively inexpensive, and fairly rugged. Available in the following configurations:

    • 1x: no attenuation
    • 10x: factor-of-10 attenuation
    • 100x: factor-of-100 attenuation
    • 1000x: factor-of-1000 attenuation

    Attenuation probes serve to multiply the voltage measurement range of the oscilloscope by using an internal resistor that, when used in conjunction with the input resistance of the scope, creates a voltage divider. Useful for the following reasons:

    • It allows for the measurement of a signal that might exceed the limits of the oscilloscope
    • The attenuation circuitry results in higher resistance and lower capacitance, which is important for high-frequency measurements

    Active probes contain active components, such as FETs or amplifiers. Commonly used for taking high-speed measurements (>500 MHz) or on high-impedance circuits. One limitation is their limited voltage range.

    Differential probes are popular for measuring high-frequency signals or signals of very low amplitude.

    A current probe measures the electrical current flowing through a conductor.

    Tips:

    • Always use an appropriate probe tip and/or probe tip adapter whenever possible
    • Keep ground leads short

    326 產品顯示為 Oscilloscope Probes

    RS PRO
    Voltage
    1:1
    25MHz
    -
    BNC
    RS-LX 112
    1
    -
    -
    -
    -
    RS-LX
    -
    14ns
    RS PRO
    Voltage
    1:1 / 10:1
    250MHz
    -
    BNC
    RS-MX 312
    1
    -
    -
    -
    -
    RS-MX
    -
    5ns
    RS PRO
    Voltage
    10:1
    350MHz
    -
    BNC
    -
    1
    -
    -
    -
    -
    RS-TP
    CAT II 400V
    <1ns
    RS PRO
    Voltage
    10:1
    150MHz
    -
    BNC
    -
    1
    -
    -
    -
    -
    RS-TP
    CAT II 400V
    <2.33ns
    RS PRO
    Voltage
    1:10
    300MHz
    1.5kV
    BNC
    -
    1
    -
    -
    -
    -
    -
    CAT I 600 V, CAT II 300V
    1.2ns
    RS PRO
    Voltage
    1:1, 1:10
    350MHz
    -
    BNC
    -
    1
    -
    -
    -
    -
    RS-TP
    CAT II 400V
    <35ns
    Tektronix
    Voltage
    1:10
    200MHz
    300V
    BNC
    TPP0200
    -
    -
    -
    -
    -
    TPP
    CAT II 300V
    -
    RS PRO
    Voltage
    10:1
    350MHz
    -
    BNC
    RS-HX 212
    1
    -
    -
    -
    -
    RS-HX
    -
    1ns
    Tektronix
    Current
    -
    ≥ 120MHz
    -
    BNC
    TCP0030A
    1
    -
    -
    ASIC
    -
    TCP
    CAT II 150 V, CAT II 300V
    2.92ns
    Tektronix
    Differential
    1:50, 1:500
    200MHz
    1.5kV
    BNC
    THDP0200
    -
    CAT II, CAT III
    -
    -
    -
    THD
    CAT II 1000 V, CAT III 600V
    1.8ps
    Pico Technology
    Current
    -
    -
    -
    BNC
    TA189
    1
    CAT III
    -
    -
    30A
    -
    CAT III 300V
    -
    Teledyne LeCroy
    Current
    -
    10MHz
    -
    ProBus
    CP150B
    -
    -
    -
    -
    -
    CP
    -
    -
    Keysight Technologies
    Voltage
    1:10
    500MHz
    -
    BNC
    N2873A
    1
    CAT I, CAT II
    400V
    -
    -
    N2870A
    CAT I 400 V, CAT II 300V
    -
    Pico Technology
    Differential
    1:1
    15MHz
    -
    D9 Connector
    441
    1
    -
    -
    -
    -
    PicoConnect
    CAT III 1000V
    -
    Tektronix
    Current
    -
    100MHz
    -
    BNC
    TCP312A
    1
    -
    -
    -
    30A
    TCP300
    CAT II 150 V, CAT II 300V
    3.5ns
    Tektronix
    Voltage
    1:10
    1GHz
    300V
    -
    TPP1000
    -
    -
    -
    -
    -
    4000, 5000
    CAT II 300V
    -
    Rohde & Schwarz
    Voltage
    10:1
    500MHz
    1kV
    BNC
    RT-ZI10
    1
    CAT III, CAT IV
    600 V, 1000 V
    -
    -
    -
    CAT III 1000 V, CAT IV 600 V
    -
    Teledyne LeCroy
    Voltage
    1:10
    500MHz
    400V
    BNC
    PP009-1
    -
    -
    -
    -
    -
    PP
    CAT I 400 V, CAT II 300V
    -
    Pico Technology
    Differential
    1:25
    10MHz
    1kV
    D9 Connector
    442
    1
    -
    -
    -
    -
    PicoConnect
    CAT III 1000V
    -
    Tektronix
    Current
    -
    25 kHz → 1GHz
    -
    -
    CT1
    -
    CAT I
    175V
    -
    0.45A
    -
    CAT I 175V
    -
    每頁顯示的結果