規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Phoenix Contact | |
| Product Type | Current Transducer | |
| Series | MCR-SL-CUC-400-I | |
| Power Rating | 1.65W | |
| Secondary Current | 25 A | |
| Terminal Type | Push-in | |
| Primary Current | 400A | |
| Minimum Operating Temperature | -40°C | |
| Maximum Operating Temperature | 65°C | |
| Width | 90 mm | |
| Standards/Approvals | UL 508, UL/C-UL Listed, CE, UKCA | |
| Weight | 294g | |
| Depth | 85mm | |
| Maximum Operating Frequency | 6000Hz | |
| Mount Type | DIN Rail | |
| Supply Voltage | 24 V dc | |
| Minimum Operating Frequency | 20Hz | |
| 選取全部 | ||
|---|---|---|
品牌 Phoenix Contact | ||
Product Type Current Transducer | ||
Series MCR-SL-CUC-400-I | ||
Power Rating 1.65W | ||
Secondary Current 25 A | ||
Terminal Type Push-in | ||
Primary Current 400A | ||
Minimum Operating Temperature -40°C | ||
Maximum Operating Temperature 65°C | ||
Width 90 mm | ||
Standards/Approvals UL 508, UL/C-UL Listed, CE, UKCA | ||
Weight 294g | ||
Depth 85mm | ||
Maximum Operating Frequency 6000Hz | ||
Mount Type DIN Rail | ||
Supply Voltage 24 V dc | ||
Minimum Operating Frequency 20Hz | ||
- COO (Country of Origin):
- CN
Phoenix Contact MCR-SL-CUC-400-I Series Current Transducer, 24V DC Supply Voltage, DIN Rail Mount - 2308072
This current transducer is suitable for measuring both AC and DC currents within an input range of 0 to 400 A. It features compact dimensions of 90x33.8x85mm, allowing for versatile application in various environments. Operating at a 24V dc supply voltage, it maintains performance in temperature extremes from -40 to +65°C.
Features & Benefits
• Universal current measurement without the need for a shunt
• 4 to 20 mA output current for compatibility with other devices
• Compact size ideal for tight spaces
• Quick response time of 150 ms for dynamic measurements
• Robust 3-way electrical isolation for safety and dependability
• Suitable for DIN rail mounting, facilitating installation
Applications
• Industrial automation monitoring systems
• Electrical panels to measure current flow
• Testing equipment in research and development
• Power management systems for real-time analysis
• Control systems for efficient energy management
Can it handle overload conditions?
Yes, it can endure up to 2.5 times the rated input current.
Is it compatible with varying environmental conditions?
It functions effectively across a broad temperature range of -40°C to +65°C.
Will it require complex installation procedures?
No, it employs simple connexion technology for straightforward setup.
Can it measure distorted currents?
Yes, it is capable of measuring AC, DC, and distorted currents effectively.
Is the current output signal adjustable?
The output signal varies from 4 mA to 20 mA.
相关链接
- Phoenix Contact MCR-SL-CUC-600-I Series DIN Rail Mounted Current Transducer 4 → 20 mA
- Phoenix Contact MCR-SL-CUC-300-I Series Current Transformer Current Transformer 300:1, 4 → 20 mA
- Phoenix Contact MCR-SL-CUC-200-I Series Current Transformer Current Transformer 200:1, 4 → 20 mA
- Phoenix Contact MCR-SL-CUC-100-U Series DIN Rail Mounted Current Transducer 20 → 30 V
- Phoenix Contact MCR-SL-S-400-U Series DIN Rail Mounted Current Transducer 18.5mm Bore, 20
- Phoenix Contact MCR-SL-S-400-I-LP Series DIN Rail Mounted Current Transducer 4 → 20 mA
- Phoenix Contact MCR-SL-CUC-100-I Series Current Transformer 100:1 32mm Bore, 20
- Phoenix Contact MACX MCR-SL-CAC-5-I Series Current Measuring Transducer Current Measuring Transducer