Royce Thompson Electric Lighting Controller Detector, Cadmium Sulfide, Wall Mount, 230 V
- RS庫存編號:
- 215-9615
- 製造零件編號:
- V16
- 製造商:
- Royce Thompson Electric
單價 个**
HK$1,384.90
26 現貨庫存,可於3工作日發貨。*
* 交貨日期可能會根據您選擇的數量和交貨地址而變更。
訂單金額滿 HK$850.00 即可享受 免費 送貨服務
單位 | 每單位 |
---|---|
1 + | HK$1,384.90 |
** 參考價格
- RS庫存編號:
- 215-9615
- 製造零件編號:
- V16
- 製造商:
- Royce Thompson Electric
Royce Thompson Electric Lighting Controller, Adjustable Lux Level, 10 to 40s Time Delay Function - V16
Fine-tune your lighting with this versatile controller from Royce Thompson Electric. With settable levels between 10 and 1,000 lux, it lets you decide on the ideal amount of brightness for foyers, hallways and underpasses. A cadmium-sulfide sensor accurately detects light changes, to be sure your system automatically switches on and off at the right time. Thanks to a switching delay between 10s and 40s, the unit resists accidental activation caused by rogue flashes of light. As it works with halogen, LED and discharge bulb types, this is a widely compatible option for use with communal, amenity and security lighting systems.
Features & Benefits
Rugged polycarbonate housing ensures durability
Low power consumption of 2.5W for energy efficiency
Wide operating temperature range between -20°C and +40°C to handle harsh conditions
Compact dimensions of 93 (L) x 67 (W) x 50mm (D) to save on space
Low power consumption of 2.5W for energy efficiency
Wide operating temperature range between -20°C and +40°C to handle harsh conditions
Compact dimensions of 93 (L) x 67 (W) x 50mm (D) to save on space
Applications
Residential blocks
Public buildings
Pedestrian walkways
Commercial and retail units
Floodlighting
Public buildings
Pedestrian walkways
Commercial and retail units
Floodlighting
What's the ingress protection rating of this lighting controller?
It has an IP54 rating, so it's protected from dust and water splashes.
Daylight Lighting Controllers
These controllers automatically turn lights 'ON' and 'OFF' in response to changes in ambient light levels, primarily the transition from day to night and vice-versa. The more advanced types (see note below) have inbuilt logic to minimise false triggering, whereas the remainder have inbuilt time delays or higher 'OFF' thresholds, to prevent on/off cycling. As a general rule, these controllers should be sited such that they are not illuminated, by the light they are controlling. Nominal supply voltage is 230Vac.,Note regarding energy-saving negative-hysteresis controllers,Where figures for the 'OFF' threshold are lower than for the 'ON' threshold, the sensor is designed such that four thresholds are actually monitored. These are: dusk, the middle of the night, dawn and the middle of the day. Monitoring at times other than dusk and dawn enables the sensor to determine what it should be looking for next, minimising false triggering and improving overall controller operation.
Attribute | Value |
---|---|
Controller Type | Detector |
Sensor Type | Cadmium Sulfide |
Voltage Rating | 230 V ac |
Mount Type | Wall |
Range | Adjustable |
Time Delay | 10 s → 40 s |
Length | 95 mm |
Width | 70 mm |
Height | 51.5mm |
Wattage | 250 mW |