Legrand 4 Poles: 10 to 60 A according to references, 2 Poles: 15 to 90 A according to references Residual Current
- RS庫存編號:
- 255-2313
- 製造零件編號:
- 401003
- 製造商:
- Legrand
小計(1 件)*
HK$2,854.15
訂單超過 HK$250.00 免費送貨
製造商存貨
- 準備從 2026年5月12日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | HK$2,854.15 |
* 參考價格
- RS庫存編號:
- 255-2313
- 製造零件編號:
- 401003
- 製造商:
- Legrand
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Legrand | |
| Number of Poles | 2 | |
| Product Type | Residual Current Circuit Breaker with Overload Protection | |
| Current Rating | 45A | |
| Tripping Characteristics | Overcurrent protection, Earth leakage current protection | |
| Rated AC Voltage | 250V ac | |
| Mount Type | Board, Panel | |
| Breaking Capacity | 2400A | |
| Range | 4 Poles: 10 to 60 A according to references, 2 Poles: 15 to 90 A according to references | |
| Terminal Type | 10° to 30° Rotating Terminal | |
| IP Rating | IP40 | |
| Standards/Approvals | NF C 62-411 (1988)+F1 (1997) et NF C 62-412 (1983)+A1 (1988), NF EN 61 543 (1996) | |
| Tripping Mechanism | Electromechanic, Magnetic | |
| 選取全部 | ||
|---|---|---|
品牌 Legrand | ||
Number of Poles 2 | ||
Product Type Residual Current Circuit Breaker with Overload Protection | ||
Current Rating 45A | ||
Tripping Characteristics Overcurrent protection, Earth leakage current protection | ||
Rated AC Voltage 250V ac | ||
Mount Type Board, Panel | ||
Breaking Capacity 2400A | ||
Range 4 Poles: 10 to 60 A according to references, 2 Poles: 15 to 90 A according to references | ||
Terminal Type 10° to 30° Rotating Terminal | ||
IP Rating IP40 | ||
Standards/Approvals NF C 62-411 (1988)+F1 (1997) et NF C 62-412 (1983)+A1 (1988), NF EN 61 543 (1996) | ||
Tripping Mechanism Electromechanic, Magnetic | ||
- COO (Country of Origin):
- FR
The Legrand enedis circuit breakers and residual current circuit breakers made for Enedis blue rate contract from 3 to 36 kVA.
Protect against overloads and short circuits
相关链接
- Legrand 15 to 90 A (2 Poles) Screw 3600 A, 440V ac
- Legrand Residual Current Circuit Breaker 2-Pole Type A
- Weidmüller BL 3.5/3...7 poles, BL 3.5/8...24 poles
- Legrand Residual Current Circuit Breaker with Overload Protection Type F 6000 A Breaking Capacity
- Legrand Residual Current Circuit Breaker with Overload Protection 10A 400V ac AC, 6000 A Breaking
- Eaton External Peripheral Connector 8 Poles for Use with SmartWire Darwin Slave to SmartWire-DT Devices
- Legrand Electronic Circuit Breaker 500 mA Overload Protection, 2400 A 440V ac
- Legrand Residual Current Circuit Breaker 2-Pole, 30 mA