Better World
Schneider Electric Acti 9 iC60H MCB, 1P, 20A Curve B, 100 → 133V AC, 72V DC, 10 kA Breaking Capacity
- RS庫存編號:
- 791-3168
- 製造零件編號:
- A9F53120
- 製造商:
- Schneider Electric
Price 个**
原價 HK$388.75
您付款
HK$173.30
86 現貨庫存,可於3工作日發貨。*
* 交貨日期可能會根據您選擇的數量和交貨地址而變更。
訂單金額滿 HK$850.00 即可享受 免費 送貨服務
單位 | 每單位 |
---|---|
1 + | HK$173.30 |
** 參考價格
Better World
我們的 Better World 產品系列可讓您輕鬆選擇值得信賴的環保產品。 點擊此處了解更多。
- RS庫存編號:
- 791-3168
- 製造零件編號:
- A9F53120
- 製造商:
- Schneider Electric
- COO (Country of Origin):
- BG
Schneider Electric Acti9 iC60H MCBs 1 Pole
C60H series multi-standard circuit breakers combine circuit protection against short circuit currents and circuit protection against overload currents it also protects people against indirect contact with TN and IT neutral systems. Fully compliant with standards IEC/EN 60898 and IEC/EN 60947-2. ACTi 9 is fully tested, approved and certified by national and international third parties. It guarantees that your installation is safe and compliant with all relevant safety standards which demonstrates to your customers that you use industry-approved materials and best practices. These MCBs are normally used for high inductive loads where switching surges are high. Providing essential protection in industrial and commercial buildings, these miniature circuit breakers work especially well in polluted environments and networks.
Features and benefits:
VisiSafe guarantees the downstream circuit is always safe regardless of overvoltage conditions, even in the most demanding environments; the green strip indicates the safe position of contacts.
VisiTrip red window on the front face indicates fault tripping allowing fast diagnosis, resolution, and reclosing loads for easier building management and reduced downtime
VisiTrip red window on the front face indicates fault tripping allowing fast diagnosis, resolution, and reclosing loads for easier building management and reduced downtime
Benefits and Features
Downstream circuit is always safe
Class-2 insulation: ensures continuous protection for both operators and unqualified persons
Insulated terminals (IP20)
Highly durable with robust connections that provide twice the standard tightening torque
Provide greater continuity of service thanks to VisiTrip
Double clip for dismounting with comb busbar in place
Class-2 insulation: ensures continuous protection for both operators and unqualified persons
Insulated terminals (IP20)
Highly durable with robust connections that provide twice the standard tightening torque
Provide greater continuity of service thanks to VisiTrip
Double clip for dismounting with comb busbar in place
Standards
IEC 60898 - Relates to Low Voltage Circuit Breakers for use in household and similar
Installations. In the UK traditionally known as miniature circuit breakers
(MCBs).
IEC 60947-2 Relates to Low Voltage Circuit Breakers for use in industrial and similar
Installations. In the UK traditionally known as moulded case circuit breakers
(MCCBs) and also air circuit breakers (ACBs).
Installations. In the UK traditionally known as miniature circuit breakers
(MCBs).
IEC 60947-2 Relates to Low Voltage Circuit Breakers for use in industrial and similar
Installations. In the UK traditionally known as moulded case circuit breakers
(MCCBs) and also air circuit breakers (ACBs).
Q: What is the differences in the Tripping Curves B, C, and D?
A: Curve B: Tripping: 3 to 5 times the rated current.
Applications: protection of generators, persons, very long cables
Curve C: Tripping: 5 to 10 times the rated current
Applications: protection of circuits and general applications
Curve D: Tripping: 10 to 14 times the rated current
Applications: protection of high surge circuits, welders, transformers and motors
Applications: protection of generators, persons, very long cables
Curve C: Tripping: 5 to 10 times the rated current
Applications: protection of circuits and general applications
Curve D: Tripping: 10 to 14 times the rated current
Applications: protection of high surge circuits, welders, transformers and motors
Schneider Electric iC60H Series MCB, 1 Pole, 20A Current Rating - A9F53120
This miniature circuit breaker (MCB) provides robust circuit protection. Designed for dependable performance, it accommodates a variety of electrical configurations. With dimensions of 85mm in length, 18mm in width, and 78.5mm in depth, this device is suitable for DIN rail mounting, ensuring efficient and secure installation. Its thermal-magnetic tripping mechanism ensures comprehensive protection for electrical circuits.
Features & Benefits
• 20A current rating for effective circuit management
• Type B MCB suitable for general use
• High breaking capacity of 10kA at maximum voltage
• Screw terminal connections for easy installation
• IP20 rated for indoor use in dry environments
• Thermal-magnetic technology for reliable tripping
• Type B MCB suitable for general use
• High breaking capacity of 10kA at maximum voltage
• Screw terminal connections for easy installation
• IP20 rated for indoor use in dry environments
• Thermal-magnetic technology for reliable tripping
Applications
• Used for residential electrical distribution boards
• Suitable for commercial building electrical systems
• Ideal for equipment protection in automation applications
• Utilised in power distribution for industrial machinery
• Suitable for commercial building electrical systems
• Ideal for equipment protection in automation applications
• Utilised in power distribution for industrial machinery
Can it handle both AC and DC applications?
Yes, it is suitable for AC/DC networks.
Will it indicate a trip event?
Yes, it features a trip indicator for easy identification.
Is it compatible with standard DIN rails?
Yes, it is designed for easy DIN rail mounting.
Can it be used in high humidity conditions?
No, it is intended for indoor use only.
Standards
EN/IEC 60947-2, EN/IEC 60898-1.
Merlin Gerin – MCBs
Miniature Circuit Breakers; Contact Position indicated by switch levers
Attribute | Value |
---|---|
Number of Poles | 1P |
Current Rating | 20A |
Tripping Characteristics | Type B |
Rated AC Voltage | 100 → 133 V, 12 → 60 V, 220 → 240V |
Rated DC Voltage | 72 V, 12 → 48V |
Breaking Capacity at Maximum Voltage Rating | 10 kA |
Range | Acti 9 |
Series | iC60H |
Circuit Breaker Type | MCB |
Length | 85mm |
Width | 18mm |
Mounting Style | DIN Rail Mount |
Depth | 78.5mm |
Model Number | A9F53120 |
Better World Verification | Green Premium |
Better World Product | Yes |
Terminal Contact Type | Screw |
Tripping Mechanism | Thermal-Magnetic |
Reset Actuator Type | Rocker Switch |