Better World
Schneider Electric Voltage Monitoring Relay, DPDT, 15 → 600 V, DIN Rail
- RS庫存編號:
- 146-187
- 製造零件編號:
- RM35UA13MW
- 製造商:
- Schneider Electric
小計(1 件)*
HK$1,486.50
訂單超過 HK$250.00 免費送貨
有庫存
- 3 件準備從其他地點送貨
- 加上 4 件從 2025年12月19日 起發貨
- 加上 9 件從 2026年1月09日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | HK$1,486.50 |
* 參考價格
Better World
我們的 Better World 產品系列可讓您輕鬆選擇值得信賴的環保產品。 點擊此處了解更多。
- RS庫存編號:
- 146-187
- 製造零件編號:
- RM35UA13MW
- 製造商:
- Schneider Electric
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Schneider Electric | |
| Monitoring Application | Voltage | |
| Contact Configuration | DPDT | |
| Voltage Sensing Range | 15 → 600 V | |
| Voltage Sensitivity | Overvoltage, Undervoltage | |
| Mounting Type | DIN Rail | |
| Time Delay | 0.3 → 30s | |
| Series | Harmony Control | |
| Better World Verification | Green Premium | |
| Better World Product | Yes | |
| Standards Met | CE, CSA, UL | |
| Width | 35mm | |
| Height | 90mm | |
| Maximum Operating Temperature | +50°C | |
| Dimensions | 72 x 35 x 90mm | |
| Minimum Operating Temperature | -20°C | |
| Maximum Voltage Sensed | 600V | |
| Terminal Type | Screw | |
| Minimum Voltage Sensed | 15 V | |
| Length | 72mm | |
| Special Features | IP20 Terminals | |
| Operating Temperature Range | +50°C | |
| 選取全部 | ||
|---|---|---|
品牌 Schneider Electric | ||
Monitoring Application Voltage | ||
Contact Configuration DPDT | ||
Voltage Sensing Range 15 → 600 V | ||
Voltage Sensitivity Overvoltage, Undervoltage | ||
Mounting Type DIN Rail | ||
Time Delay 0.3 → 30s | ||
Series Harmony Control | ||
Better World Verification Green Premium | ||
Better World Product Yes | ||
Standards Met CE, CSA, UL | ||
Width 35mm | ||
Height 90mm | ||
Maximum Operating Temperature +50°C | ||
Dimensions 72 x 35 x 90mm | ||
Minimum Operating Temperature -20°C | ||
Maximum Voltage Sensed 600V | ||
Terminal Type Screw | ||
Minimum Voltage Sensed 15 V | ||
Length 72mm | ||
Special Features IP20 Terminals | ||
Operating Temperature Range +50°C | ||
Schneider Electric Harmony Control Series Monitoring Relay, DPDT Contact Configuration, Voltage Monitoring Application - RM35UA13MW
This monitoring relay is designed for effective voltage control in various electrical setups, playing a crucial role in the protection and efficiency of electrical systems by detecting both overvoltage and undervoltage conditions. It is particularly suited for industrial automation, enhancing reliability across critical applications.
Features & Benefits
• Dual-pole, double-throw (DPDT) configuration simplifies switching processes
• Adjustable time delay ranging from 0.3 to 30 seconds caters to diverse applications
• Voltage sensing range of 15 to 600V supports a variety of systems
• Screw terminal connections ensure secure and straightforward installation
• Maximum switching capacity of 1250 VA for enhanced performance
• Designed for DIN rail mounting for efficient use of space
• Adjustable time delay ranging from 0.3 to 30 seconds caters to diverse applications
• Voltage sensing range of 15 to 600V supports a variety of systems
• Screw terminal connections ensure secure and straightforward installation
• Maximum switching capacity of 1250 VA for enhanced performance
• Designed for DIN rail mounting for efficient use of space
Applications
• Monitoring voltage levels in industrial machinery
• Protecting sensitive electronic equipment
• Utilising in control panels for voltage management
• Employed in automation systems for real-time monitoring
• Applied in energy distribution systems to enhance safety and efficiency
• Protecting sensitive electronic equipment
• Utilising in control panels for voltage management
• Employed in automation systems for real-time monitoring
• Applied in energy distribution systems to enhance safety and efficiency
What is the installation process for this device?
It can be easily mounted on a DIN rail, providing stable installation and accessibility for maintenance.
How does it manage voltage anomalies?
The relay detects overvoltage and undervoltage, activating safety measures to prevent damage.
What is the response time for voltage detection?
The device features a configurable time delay from 0.3 to 30 seconds, allowing for customised response to voltage fluctuations.
Can it be used in a high-temperature environment?
It operates efficiently within a temperature range of -20°C to +50°C, suitable for most industrial conditions.
Approvals
UL, CSA, GL, C-Tick, GOST
Standards
NF EN 60255-6 and IEC 60255-6
Schneider Electric Voltage, Current, Phase & Motor Protection
相关链接
- Crouzet Voltage Monitoring Relay 15 → 600 V, DIN Rail
- Schneider Electric Voltage Monitoring Relay DPDT DIN Rail
- Schneider Electric Voltage Monitoring Relay DPDT DIN Rail
- Tele Voltage Monitoring Relay DPDT, DIN Rail
- GIC Voltage Monitoring Relay DPDT, DIN Rail
- Dold Voltage Monitoring Relay DIN Rail
- RS PRO Voltage Monitoring Relay DPDT, DIN Rail
- Tele Voltage Monitoring Relay DPDT, DIN Rail