Broyce Control Phase, Voltage Monitoring Relay, 3 Phase, SPDT, 243 → 540V ac, DIN Rail
- RS庫存編號:
- 135-6181
- 製造零件編號:
- LPRC/2 400V
- 製造商:
- Broyce Control
小計(1 件)*
HK$848.20
訂單超過 HK$250.00 免費送貨
有庫存
- 19 件準備從其他地點送貨
- 加上 11 件從 2026年2月06日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | HK$848.20 |
* 參考價格
- RS庫存編號:
- 135-6181
- 製造零件編號:
- LPRC/2 400V
- 製造商:
- Broyce Control
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Broyce Control | |
| Monitoring Application | Phase, Voltage | |
| Electrical Phase | 3 | |
| Contact Configuration | SPDT | |
| Voltage Sensing Range | 243 → 540V ac | |
| Voltage Sensitivity | Overvoltage, Undervoltage | |
| Mounting Type | DIN Rail | |
| Phase Sensitivity | Phase Failure, Phase Sequence | |
| Time Delay | 0.2 → 10s | |
| Series | L | |
| Width | 17.5mm | |
| Number of Poles | 2 | |
| Height | 89mm | |
| Minimum Operating Temperature | -20°C | |
| Dimensions | 66.5 x 17.5 x 89mm | |
| Maximum Voltage Sensed | 540V | |
| Maximum Operating Temperature | +60°C | |
| Length | 66.5mm | |
| Operating Temperature Range | +60°C | |
| Terminal Type | Screw | |
| Special Features | Microprocessor Based, Detects Incorrect Phase Sequence, Phase Loss And Neutral Loss, Adjustments For Under And Over Voltage Trip Levels, Adjustment For Time Delay | |
| 選取全部 | ||
|---|---|---|
品牌 Broyce Control | ||
Monitoring Application Phase, Voltage | ||
Electrical Phase 3 | ||
Contact Configuration SPDT | ||
Voltage Sensing Range 243 → 540V ac | ||
Voltage Sensitivity Overvoltage, Undervoltage | ||
Mounting Type DIN Rail | ||
Phase Sensitivity Phase Failure, Phase Sequence | ||
Time Delay 0.2 → 10s | ||
Series L | ||
Width 17.5mm | ||
Number of Poles 2 | ||
Height 89mm | ||
Minimum Operating Temperature -20°C | ||
Dimensions 66.5 x 17.5 x 89mm | ||
Maximum Voltage Sensed 540V | ||
Maximum Operating Temperature +60°C | ||
Length 66.5mm | ||
Operating Temperature Range +60°C | ||
Terminal Type Screw | ||
Special Features Microprocessor Based, Detects Incorrect Phase Sequence, Phase Loss And Neutral Loss, Adjustments For Under And Over Voltage Trip Levels, Adjustment For Time Delay | ||
- COO (Country of Origin):
- GB
LPRC/2 Phase Failure, Phase Sequence, Under and Over Voltage plus Time Delay
Broyce Controls L-Series signal conditioners use a QR barcode marking method allowing direct access to all technical data sheets, ensuring correct information is always at your finger tips!
Features and Benefits
Compact 17.5 mm DIN Rail housing
Microprocessor based
True R.M.S. monitoring measuring phase to phase (three wire) or phase to neutral (4-wire) voltages
Selectable nominal voltages to suit most popular three wire or 4-wire supply voltages
Monitors own supply and detects if one or more phases exceed the set Under or Over voltage trip levels
Detects incorrect phase sequence, phase loss and neutral loss1
Adjustments for Under and Over voltage trip levels
Adjustment for time delay
Independent relay outputs - Under voltage monitoring / Over voltage monitoring
2 x SPDT relay output 5A
Green LED indication for supply status
Individual Red LED indication for both relay statuses
Approvals
UL Certification
Broyce Monitor Relays
Note
Output relay contact rating specified at 250Vac
相关链接
- Broyce Control Phase 3 Phase 243 → 540V ac, DIN Rail
- Broyce Control Phase 3 Phase 243 → 540V ac, DIN Rail
- Broyce Control Phase 3 Phase 266 → 540V ac, DIN Rail
- Broyce Control Phase 3 Phase 243 → 540 V, DIN Rail
- Broyce Control Phase 3 Phase DIN Rail
- Broyce Control Phase 1 Phase DIN Rail
- Broyce Control Phase 3 Phase 280 → 520V ac, DIN Rail
- Broyce Control Voltage Monitoring Relay SPDT DIN Rail