Broyce Control Voltage Monitoring Relay, 1 Phase, SPDT, Maximum of 315 V, DIN Rail
- RS庫存編號:
- 135-6187
- 製造零件編號:
- LCVR/2 230V
- 製造商:
- Broyce Control
小計(1 件)*
HK$685.50
訂單超過 HK$250.00 免費送貨
- 14 件準備從其他地點送貨
單位 | 每單位 |
|---|---|
| 1 + | HK$685.50 |
* 參考價格
- RS庫存編號:
- 135-6187
- 製造零件編號:
- LCVR/2 230V
- 製造商:
- Broyce Control
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Broyce Control | |
| Monitoring Application | Voltage | |
| Electrical Phase | 1 | |
| Voltage Sensing Range | Maximum of 315 V | |
| Contact Configuration | SPDT | |
| Voltage Sensitivity | Overvoltage, Undervoltage | |
| Mounting Type | DIN Rail | |
| Phase Sensitivity | Single Phase | |
| Time Delay | 0.2 → 10s | |
| Frequency Sensing Range | 48 → 63Hz | |
| Series | L | |
| Height | 89mm | |
| Width | 17.5mm | |
| Maximum Operating Temperature | +60°C | |
| Length | 66.5mm | |
| Operating Temperature Range | +60°C | |
| Maximum Voltage Sensed | 315V | |
| Terminal Type | Screw | |
| Dimensions | 66.5 x 17.5 x 89mm | |
| Minimum Operating Temperature | -20°C | |
| Number of Poles | 2 | |
| Special Features | Microprocessor Based, Monitors Own Supply And Detects If The Set Under Or Over Voltage Trip Levels Are Exceeded, Adjustments For Under And Over Voltage Trip Levels, Adjustment For Time Delay, Green Led Indication For Supply Status | |
| 選取全部 | ||
|---|---|---|
品牌 Broyce Control | ||
Monitoring Application Voltage | ||
Electrical Phase 1 | ||
Voltage Sensing Range Maximum of 315 V | ||
Contact Configuration SPDT | ||
Voltage Sensitivity Overvoltage, Undervoltage | ||
Mounting Type DIN Rail | ||
Phase Sensitivity Single Phase | ||
Time Delay 0.2 → 10s | ||
Frequency Sensing Range 48 → 63Hz | ||
Series L | ||
Height 89mm | ||
Width 17.5mm | ||
Maximum Operating Temperature +60°C | ||
Length 66.5mm | ||
Operating Temperature Range +60°C | ||
Maximum Voltage Sensed 315V | ||
Terminal Type Screw | ||
Dimensions 66.5 x 17.5 x 89mm | ||
Minimum Operating Temperature -20°C | ||
Number of Poles 2 | ||
Special Features Microprocessor Based, Monitors Own Supply And Detects If The Set Under Or Over Voltage Trip Levels Are Exceeded, Adjustments For Under And Over Voltage Trip Levels, Adjustment For Time Delay, Green Led Indication For Supply Status | ||
- COO (Country of Origin):
- GB
LCVR/2 Under and Over Voltage plus Time Delay
Features and Benefits
Approvals
Note
相关链接
- Broyce Control Phase 1 Phase DIN Rail
- Broyce Control Phase 3 Phase DIN Rail
- Broyce Control Temperature Monitoring Relay DIN Rail
- Broyce Control Current Monitoring Relay DIN Rail
- Tele Voltage Monitoring Relay SPDT Maximum of 24V dc, DIN Rail
- Broyce Control Phase 3 Phase 280 → 520V ac, DIN Rail
- Broyce Control Phase 3 Phase 266 → 540V ac, DIN Rail
- Broyce Control Phase 3 Phase 243 → 540V ac, DIN Rail