Tele Voltage Monitoring Relay, 3 Phase, DPDT, DIN Rail
- RS庫存編號:
- 182-9992
- Distrelec 貨號:
- 137-54-202
- 製造零件編號:
- E3YF400V02 0.85
- 製造商:
- Tele
小計(1 件)*
HK$1,034.51
訂單超過 HK$250.00 免費送貨
有庫存
- 4 件準備從其他地點送貨
- 加上 4 件從 2026年2月05日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | HK$1,034.51 |
* 參考價格
- RS庫存編號:
- 182-9992
- Distrelec 貨號:
- 137-54-202
- 製造零件編號:
- E3YF400V02 0.85
- 製造商:
- Tele
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Tele | |
| Monitoring Application | Voltage | |
| Electrical Phase | 3 | |
| Contact Configuration | DPDT | |
| Voltage Sensitivity | Undervoltage | |
| Mounting Type | DIN Rail | |
| Time Delay | 200ms | |
| Frequency Sensing Range | 48 → 63Hz | |
| Series | ENYA | |
| Maximum Operating Temperature | +55°C | |
| Maximum Frequency Sensed | 63Hz | |
| Length | 65mm | |
| Minimum Operating Temperature | -25°C | |
| Height | 87mm | |
| Width | 35mm | |
| Operating Temperature Range | +55°C | |
| Dimensions | 65 x 35 x 87mm | |
| Minimum Frequency Sensed | 48Hz | |
| 選取全部 | ||
|---|---|---|
品牌 Tele | ||
Monitoring Application Voltage | ||
Electrical Phase 3 | ||
Contact Configuration DPDT | ||
Voltage Sensitivity Undervoltage | ||
Mounting Type DIN Rail | ||
Time Delay 200ms | ||
Frequency Sensing Range 48 → 63Hz | ||
Series ENYA | ||
Maximum Operating Temperature +55°C | ||
Maximum Frequency Sensed 63Hz | ||
Length 65mm | ||
Minimum Operating Temperature -25°C | ||
Height 87mm | ||
Width 35mm | ||
Operating Temperature Range +55°C | ||
Dimensions 65 x 35 x 87mm | ||
Minimum Frequency Sensed 48Hz | ||
- COO (Country of Origin):
- AT
Voltage monitoring 3-phase against N, Voltage failure monitoring, 400V, 2 CO, fixed threshold voltage Us=195,5V
Monitoring relays - ENYA series
Undervoltage monitoring
Supply voltage = measured voltage
2 change over contacts
Width 35 mm
Installation design
Task
The emergency lighting is activated in the event of a mains failure or undervoltage.
Solution
The mains failure is monitored with a E3YF400V02 (three phases). If the voltage falls below 85% of the nominal voltage, the output relay trips and turns the emergency lights on.
Use/value
Detects mains failure
Applications
Emergency Power
Facility Management
Renewable Energy
Undervoltage monitoring
Supply voltage = measured voltage
2 change over contacts
Width 35 mm
Installation design
Task
The emergency lighting is activated in the event of a mains failure or undervoltage.
Solution
The mains failure is monitored with a E3YF400V02 (three phases). If the voltage falls below 85% of the nominal voltage, the output relay trips and turns the emergency lights on.
Use/value
Detects mains failure
Applications
Emergency Power
Facility Management
Renewable Energy