ABB Phase, Voltage Monitoring Relay, 3 Phase, DPDT, 180 → 280V ac, DIN Rail

小計(1 件)*

HK$2,574.70

Add to Basket
選擇或輸入數量
有庫存
  • 16 件準備從其他地點送貨
  • 加上 6 件從 2026年1月09日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +HK$2,574.70

* 參考價格

RS庫存編號:
775-7918
製造零件編號:
1SVR730885R3300 CM-MPS.21S
製造商:
ABB
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

ABB

Monitoring Application

Phase, Voltage

Electrical Phase

3

Voltage Sensing Range

180 → 280V ac

Contact Configuration

DPDT

Voltage Sensitivity

Overvoltage, Undervoltage

Mounting Type

DIN Rail

Phase Sensitivity

NEUTRAL, Phase Failure, Phase Imbalance, Phase Sequence

Time Delay

0.1 → 30 s, 0s

Frequency Sensing Range

45 → 65Hz

Series

CM-MPS

Maximum Operating Temperature

+60°C

Operating Temperature Range

-25 → +60°C

Minimum Operating Temperature

-25°C

Maximum Voltage Sensed

280V ac

Width

22.5mm

Terminal Type

Screw

Dimensions

103.7 x 22.5 x 85.6mm

Height

85.6mm

Length

103.7mm

Minimum Voltage Sensed

180V ac

Standards Met

UL

COO (Country of Origin):
DE

ABB CM-MPS Series Monitoring Relay, DPDT Contact Configuration, 180 to 280V AC Voltage Sensing Range - 1SVR730885R3300 CM-MPS.21S


This monitoring relay is a multifunctional device from the CM-MPS series, designed for effective monitoring in three-phase applications. With dimensions of 103.7 x 22.5 x 85.6mm, it operates within a voltage sensing range of 180-280 V AC and can handle electrical phases of up to three. The relay provides essential protection against voltage fluctuations and phase-related issues, ensuring system reliability.

Features & Benefits


• Monitors overvoltage and undervoltage conditions
• Detects phase imbalance and phase failure
• Adjustable tripping delay between 0 and 30 seconds
• Utilises DPDT contact configuration for versatile applications
• Suitable for mounting on standard DIN rails
• Wide operating temperature range from -25 to +60°C

Applications


• Used in industrial automation systems
• Suitable for three-phase electrical supply monitoring
• Employed in settings requiring phase sequence verification
• Ideal for needing neutral interruption detection

How does the adjustable tripping delay enhance reliability in operations?


The adjustable tripping delay allows custom configuration between instantaneous and 30 seconds, enabling users to optimise the response time to faults without unnecessary interruptions. This ensures a fine balance between prompt action and avoiding nuisance tripping during transient conditions.

What are the key advantages of utilising a DPDT configuration?


The DPDT configuration offers flexibility by allowing two separate circuits to be managed simultaneously, providing enhanced control over monitoring and switching operations in various applications. This is particularly beneficial in complex systems where multiple conditions need to be monitored at once.

In which scenarios should the voltage sensitivity features be applied?


These voltage sensitivity features are crucial in environments prone to fluctuations, ensuring that equipment operates only within safe voltage limits. By monitoring both over and undervoltage events, it protects machinery from damage and enhances operational safety.

相关链接