- RS庫存編號:
- 775-7902
- 製造零件編號:
- 1SVR730884R3300 CM-MPS.41S
- 製造商:
- ABB
當前暫無庫存,可於2024/5/10發貨,3 工作日送達。
已增加
單價 个
原價 HK$2,331.84
您付款
HK$1,670.44
單位 | Per unit |
1 + | HK$1,670.44 |
- RS庫存編號:
- 775-7902
- 製造零件編號:
- 1SVR730884R3300 CM-MPS.41S
- 製造商:
- ABB
法例與合規
- COO (Country of Origin):
- DE
產品詳細資訊
ABB Monitoring Relay, 4A Maximum Current Rating, 0 to 30s Adjustable Time Delay - CM-MPS Series - 1SVR730884R3300 CM-MPS.41S
Shut down electrical faults before they reach your gear with this monitoring relay from ABB. It watches out for phase failure, overvoltage and undervoltage, packing comprehensive electrical protection into one handy component. When the unit detects a problem, it instantly trips the circuit breaker, so it's sure to stop faults from becoming hazardous and drives down the risk of hardware damage. Fast DIN rail mounting means you can leave your tools in the box.
Features & Benefits
Wide voltage monitoring range between 300 and 500V AC, fitting in with many power supplies
Electrical service life of 100,000 cycles for long-lasting fault detection
Narrow body measurements of 103.7 (L) x 22.5 (W) x 85.6mm (H) to slot into busy cabinets
Built-in time delay between 0 and 30s gives you the option to filter out noise and transient events
Electrical service life of 100,000 cycles for long-lasting fault detection
Narrow body measurements of 103.7 (L) x 22.5 (W) x 85.6mm (H) to slot into busy cabinets
Built-in time delay between 0 and 30s gives you the option to filter out noise and transient events
Applications
Food production
Packing plants
Manufacturing industry
Packing plants
Manufacturing industry
Do I need to connect an extra power supply to use this relay?
No, this unit's powered by the circuit it monitors, so there's no need to hook up a separate electrical supply.
規格
Attribute | Value |
---|---|
Monitoring Application | Phase, Voltage |
Electrical Phase | 3 |
Contact Configuration | DPDT |
Voltage Sensing Range | 300 → 500V ac |
Voltage Sensitivity | Overvoltage, Undervoltage |
Mounting Type | DIN Rail |
Phase Sensitivity | Phase Failure, Phase Imbalance, Phase Sequence |
Time Delay | 0.1 → 30 s, 0s |
Frequency Sensing Range | 45 → 65Hz |
Series | CM-MPS |
Height | 85.6mm |
Current Range | 2 → 4A |
Dimensions | 103.7 x 22.5 x 85.6mm |
Maximum Operating Temperature | +60°C |
Width | 22.5mm |
Minimum Operating Temperature | -25°C |
Standards Met | UL |
Terminal Type | Screw |
Operating Temperature Range | -25 → +60°C |
Minimum Voltage Sensed | 300V ac |
Length | 103.7mm |
Maximum Voltage Sensed | 500V ac |